MAGNASPHERE MSS Standard Series Dimensions

MAGNASPHERE CORP. | 23777 Stone Ridge Dr., Suite 160, Waukesha, WI 53188
tel. 262.347.0711 | fax 262.347.0710 | www.MAGNASPHERE.com
MSS Standard
Series Product Sheet
Security Contacts have been made with a
decades-old technology called the Reed switch.
Reed switches have three inherent weaknesses
when used in security contacts. They are (1)
Easily defeated with magnets, (2) Prone to
permanent contact weld failure (from lightning
and power surges), and (3) fragile (made mostly
of glass, theyare subject to damage even when
packaged as security contacts).
The MAGNASPHERE line of security sensors
provides a solution to all of these issues.
Utilizing the the patented, revolutionary
MAGNASPHERE
®
BMS switch renders the MSS
products virtuallyunbreakable, and highly
resistant to permanent contact welding and
outsider magnet defeat, allowing
MAGNASPHERE to offer a lifetime replacement
warranty.
MSS contacts are available in both the
traditional Closed Loop (contact closed when
magnet is present) as well as the more Secure
Open Loop (contact open when magnet is
present) electrical configuration. This is the
same configuration required for other life safety
devices such as smoke and fire alarms, and has
long been the recommend configuration by
most knowledgeable security professionals.
FEATURES
•Made with MAGNASPHERE
®
BMS switch
technology
•Won't break
•Resistant to contact welding
•Resistant to outside defeat
•Security industry's BEST warranty
•Universal mounting
•Cost competitive
•Increases RMR
Concealed/Recessed
Surface Mount
Overhead Door
Wireless
PATENTED DESIGN
#5977873, #RE39731, #6506987, #6303845, #6603378, and Patents Pending
Door Frame
Door
Magnet
CLOSED
SECURE: NO ALARM
Door
Magnet
NO ALARM
Door Frame
Door
Magnet
CLOSED
Door Opened
Door Frame
CLOSED
FAILED: NO ALARM
Defeat
Magnet
FAILED: NO ALARM
Door Opened
Door Frame
WELDED
CLOSED
Reed contacts operate on magnetic fields.
Most contacts are Closed in the secure
position (Closed Loop) when the door is
closed and the magnet is near the switch.
When closed reed contacts are exposed to
power surges such as lightning strikes, they
are prone to permanent contact welding.
Introducing a defeat
magnet OUTSIDE
the door will keep
the reed contacts
closed, allowing
an intruder to enter
without alerting
the security system.
They
FAIL SECURE.
Reed switch contacts are globally magnetic:
they will respond to the strongest magnetic
field anywhere around the contact –– not
solely to the door magnet. When compromised,
reed contacts will still send secure signals.
Reed contacts operate by magnetic induction,
so they are not attracted to the door magnet.
Once contacts have
welded closed, they
remain in that state
though the door is open.
They
FAIL SECURE.
Security contacts are made with a decades-old technology called the Reed switch.
Reed switches have three inherent weaknesses when used in security contacts: (1)
Easily defeated with magnets,
(2)
Prone to permanent contact weld failure
(from lightning and power surges), and (3)
fragile
(made mostly of glass,
they are subject to damage even when packaged as security contacts).
www.MAGNASPHERE.com
© MAGNASPHERE CORP.
MAGNASPHERE®®
Reed vs.
MAGNASPHERE security sensors' magnet
ball contact is open in the secure position
(Open Loop) when the door is closed and
the door magnet is near the switch.
MAGNASPHERE Security Sensors are Open
Loop and highly resistant to contact welding
from power surges and lightning strikes.
A defeat magnet
introduced OUTSIDE
the door will have no
effect on the ball
contact. When the
door is opened, the
contact will close,
and the
SYSTEM
WILL ALARM.
Because the magnet
ball contact will not
weld, when the door
is opened the
contact will close
and the
SYSTEM
WILL ALARM.
MAGNASPHERE’s contact is a spherical
magnet and operates in a defined activation
zone directed toward the door magnet.
The patented, award-winning MAGNASPHERE switch technology was designed as
a security device which over comes the deficiencies of reed contacts.
The MAGNASPHERE
switch is (1)
Resistant to magnetic defeat and tamper,
(2)
Resistant to permanent contact welding
from lightning
and power surges, and (3) Robust, all metal welded construction is
virtually unbreakable.
www.MAGNASPHERE.com
© MAGNASPHERE CORP.
MAGNASPHERE®®
Reed vs.
The Door is Closed
OPEN
SECURE: NO ALARM
The Door is Closed
OPEN
NO ALARM
ALARM
The Door is Open
CLOSED
Defeat
Magnet
ALARM
The Door is Open
CLOSED

Popular Cables And Connectors manuals by other brands

Sandberg USB Share Link PC-MAC manual

Sandberg

Sandberg USB Share Link PC-MAC manual

Renkforce DVD Maker II operating instructions

Renkforce

Renkforce DVD Maker II operating instructions

FasTest FasMate Series Rebuild Instructions

FasTest

FasTest FasMate Series Rebuild Instructions

Baumer HEAG 171 Installation and operating instructions

Baumer

Baumer HEAG 171 Installation and operating instructions

Kyocera 6882 Series instruction manual

Kyocera

Kyocera 6882 Series instruction manual

Siemens SENTRON VL160X operating instructions

Siemens

Siemens SENTRON VL160X operating instructions

MakerBot Replicator 2X How to replace

MakerBot

MakerBot Replicator 2X How to replace

Vivanco USB NET-N 23428 manual

Vivanco

Vivanco USB NET-N 23428 manual

auray ABC Series owner's manual

auray

auray ABC Series owner's manual

National Instruments SCXI-1356 installation guide

National Instruments

National Instruments SCXI-1356 installation guide

CommScope FIST-RSKG-16 installation instructions

CommScope

CommScope FIST-RSKG-16 installation instructions

Siemens SIMATIC 6ES7158-3MU10-0XA0 Hardware Installation and Operating Manual

Siemens

Siemens SIMATIC 6ES7158-3MU10-0XA0 Hardware Installation and Operating Manual

Lister SB 113 H instruction manual

Lister

Lister SB 113 H instruction manual

FasTest ICON 60 instructions

FasTest

FasTest ICON 60 instructions

Philips SWA2138W Specifications

Philips

Philips SWA2138W Specifications

Altronix eBridge100RMT Kit installation guide

Altronix

Altronix eBridge100RMT Kit installation guide

Philips SWV3513W Specifications

Philips

Philips SWV3513W Specifications

Emtron KV Series Hardware manual

Emtron

Emtron KV Series Hardware manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.