Caution: Please read this manual carefully before using the device.
Damage caused by misuse is not covered by the warranty.
RM-6000 PUPITRE MICRO
• About this manual
Dear User :
Thank you for choosing a MAJORCOM product. Before using RM-6000 and LM-6000, please read the this
user manual, so you can know how to use our device.
Please keep the user manual in a safe place so you can check it again if you have any questions during
use.
• Objective : Assists with the installation, conguration and operation of the RM-6000 and LM-6000.
• Target people : Users or installers of the RM-6000 & LM-6000.
1
2
3
4
5
8
7
6
(1) Flexible microphone
(2) Power LED
(3) Call in progress LED
(4) BUSY LED
(5) Selected zone LED
(6) Zone selection buttons
(7) Select all zones button
(8) Call button
911 1210 1413
(9) On/O switch
(10) RJ45 connection via Ethernet
cable (cascading cabling of the remote
microphone)
(11) Micro volume
(12) Auxiliary input
(13) Conguration DIP switch
(14) Addressing plan of the microphone
panels from 1 to 6
Address adjustment diagram (4 is used to detect
termination resistance)
RM-6000 | LM-6000 RM-6000 | LM-6000REMOTE MICROPHONE & WALL VOLUME CONTROLE FOR PX-6120 REMOTE MICROPHONE & WALL VOLUME CONTROLE FOR PX-6120

56, chemin de la Flambère • 31300 Toulouse • FRANCE • Tél. 33 (0)5 61 31 86 87
4
56, chemin de la Flambère • 31300 Toulouse • FRANCE • Tél. 33 (0)5 61 31 86 87
5
Manuel d’utilisationUser manual
(1) DIP Conguration Switch
(2) Connection terminal block (be careful to close the cover before wiring)
(3) RS-485 A link
(4) RS-485 B link
(5) AUDIO + link
(6) AUDIO Link –
(7) Power Link +24VDC
(8) GND
(9) Top Source Selection
(10) Bluetooth control
(11) Down Source Selection
(12) Display
(13) Volume +
(14) Volume -
DIAGRAM OF THE FRONT AND REAR PANELS OF THE LM-6000 WALL CONTROLLER CONNECTION AND CONFIGURATION
1. The matrix amplier has 5 input channels and a full multi-source audio player.
2. Mic inputs 1, 2, and 3 are designed for mic or line level sources such as CD or MP3 players or
blender outputs. Thanks to the combo connector on the back panel, they can be switched via DIP switches.
3. Can accept an XLR plug or 6.35mm jack (balanced or unbalanced signal).
4. Supports up to 6 microphone panels and or up to 6 wall control panels.
5. The connection setting must match the address. Please refer to the back panel or bottom case of
the device.
DIP SWITCH
1. The Mic /Line 1, 2 and 3 inputs each have 2 DIP switches set on the back panel and activate the
+48V phantom power condenser microphone.
2. Set the correct level for the connected input source (MIC or line).
3. If the connected source is a condenser microphone that requires phantom power, please make
sure the phantom channel is enabled.
4. Be sure to disable these DIP switches when setting up the extender. Any change in the power
supply of the amplier can cause loud noise in the system, which can damage the speaker.
5. The DIP switches on the paging microphone and wall control panel are used to congure the
address to avoid conicts.
THE MICROPHONE (RM-6000) SPEAKS TO THE FIRST SELECTION
1. Press the Z1 key on the microphone (RM-6000), the call indicator lights up, and the host’s digital
display displays C0; press the green CALL key to start talking.
2. If you need to speak throughoutthe zones, you can press the ALL button to quickly select all the
zones, and then press the CALL button to start speaking. The LEDs on the main panel all display C0.
3. If the microphone control (RM-6000) is not valid, please check if the composition code of the DIP
address switch on the back panel is correct, if it matches and if there is a conict.
FOR DIP SWITCH SETTING
Change the sound source using the adjustment button on the front panel of the main unit or the touchscreen
button on the wall control panel.
RM-6000 | LM-6000 RM-6000 | LM-6000REMOTE MICROPHONE & WALL VOLUME CONTROLE FOR PX-6120 REMOTE MICROPHONE & WALL VOLUME CONTROLE FOR PX-6120
3
4
5
6
7
8
10
11
14
12
13
9
1
2

56, chemin de la Flambère • 31300 Toulouse • FRANCE • Tél. 33 (0)5 61 31 86 87
6
56, chemin de la Flambère • 31300 Toulouse • FRANCE • Tél. 33 (0)5 61 31 86 87
7
Manuel d’utilisationUser manual
CAREFUL
1. Do not install the system equipment in direct sunlight or near a heating element, as the device may
deform, fade or go into a protective state due to the high temperature and stop working.
2. Do not install the system equipment or store it in a dusty and damp place, otherwise it will lead to
unstability of the system equipment or intermittent failure.
3. To prevent the equipment from being aected by a high electromagnetic eld, the equipment should be
as far away as possible from the strong magnetic eld equipment.
Note: Bluetooth connection, initially without password.
Balanced audio 100V/70V Unbalanced audio 8 Ohms
1. If you need to use the wall control panel (LM-6000) to select the source, use the more or less
channel keys on the control panel to adjust the desired source.
2. If you need to stream Bluetooth separately, press the Bluetooth switch button, the panel displays
C7, and the Bluetooth device can stream Bluetooth audio. The volume up and down buttons are used to
adjust the volume.
3. If the control panel (LM-6000) is not displayed, check if the cable is properly connected. For the
corresponding connection method, please refer to the description in the upper right corner of the network
port on the back panel and the bottom box on the control panel (LM-6000).
4. If the control panel control (LM-6000) is not valid, please check if the composition of the dip address
switch of the rear control panel (LM-6000) is correct, if it matches and if there is a conict.
LM-6000 BLUETOOTH WALL CONTROL PANEL
RM-6000 | LM-6000 RM-6000 | LM-6000REMOTE MICROPHONE & WALL VOLUME CONTROLE FOR PX-6120 REMOTE MICROPHONE & WALL VOLUME CONTROLE FOR PX-6120
WIRING DIAGRAMS

56, chemin de la Flambère • 31300 Toulouse • FRANCE • Tél. 33 (0)5 61 31 86 87
User manual
REMOTE MICROPHONE & WALL VOLUME CONTROL
FOR MATRIX PX-6120
RM-6000
LM-6000
This manual suits for next models
1
Other Majorcom: Microphone manuals