manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Marco
  6. •
  7. Water Dispenser
  8. •
  9. Marco ECOBOILER UC10 User manual

Marco ECOBOILER UC10 User manual

For more information visit www.marcobeveragesystems.com
ECOBOILER / ECOSMART UC10 / UC45 SAMPLE SET-UP
ECOBOILER/ECOSMART UC10/UC45
WATER
TYPE SIZE PERFORMANCE SPECS PLUMBING &
ELECTRICAL REQS PACKAGING
NAME
ORDER CODE
TEMP
ADJUST
DIMENSIONS
(D x W x H mm)
IMMEDIATE
DRAW OFF L/HR CUPS
/HR
POWER
@220V
PLUMBING
REQS
PACKAGING
DIMENSIONS
(L x W x H mm)
PACKED
WEIGHT
QTY/
PALLET
Ecosmart UC10
1000751 Y
395 x 228 x 585 10L 28L 156 2.8kW 3/4” BSP 550 x 320 x 750 12.5kg 10
Ecoboiler UC10
1000741 N
Ecosmart UC45
1000754 Y
495 x 420 x 667 45L 56L 311 5.6kW 3/4” BSP 600 x 520 x 700 22kg 4
Ecoboiler UC45
1000744A N
BOILERS FONTS
PRODUCT INFO FONT DIMENSIONS PACKAGING
NAME
ORDER CODE
DIMENSIONS
INCL. DRIP TRAY
(D x W x H mm)
DIMENSIONS
EXCL. DRIP TRAY
(D x W x H mm)
TAP TO
COUNTER
(T mm)
PACKED
WEIGHT
PACKAGING
DIMENSIONS
(L x W x H mm)
QTY/
PALLET
Über Font
1 connection
1000812
470 x 250 x 400
n/a
295
7kg 490 x 280 x 670 24
Über Font
2 connections
1000811
Über Font (Low)
1 connection
1000812L
470 x 250 x 272 172
Über Font (Low)
2 connections
1000811L
OR
H
D
W
For more information visit www.marcobeveragesystems.com
ECOBOILER/ECOSMART UC10/UC45
ÜBER FONT WITH ECOBOILER/ECOSMART UC10/UC45
COUNTER CUT-OUT
ÜBER FONT 1000811
ECOBOILER UC10
1000741
ECOBOILER UC45
1000744A
ECOSMART UC10
1000752
ECOSMART UC45
1000754
VENTILATION REQUIREMENTS
50mm/1.9” clearance required at each side and back of
machine if installed in an enclosed cabinet.
ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local
regulations and standards. The standard machine is
supplied with a UK 3-pin plug. For EU models a 2-pin CEE-7
plug will be supplied. US models will be supplied with the
suitable plug. A suitable mains power supply socket should
be available within easy access of the appliance so that it
can be disconnected easily after install. The wires from the
font are terminated in a Mini Fit connector which will plug
into a similar Mini Fit connector mounted on the top lid of
the undercounter boiler.
PLUMBING INSTALLATION PROCEDURE
• Ensure that the equipment is installed according to local
plumbing & water regulations.
• Mains water pressure required (limits): 14.5 - 145psi
(100 - 1000kPa, 0.1 - 1MPa).
• Requires inline water filter within your water
specifications.
• The machine is supplied with a 3/4“ BSP connection.
• Turn on the water to flush any impurities, dust etc
from the inlet hose and water pipe. Allow several litres
through. Especially for new installations. Connect the
hose to the inlet valve of the boiler. Make sure a sealing
washer is fitted.
• Turn on water and check for leaks.
• If the overflow vent is plumbed it must be plumbed with
a tundish device.
• This equipment must be installed with adequate
backflow protection to comply with all applicable
federal, state and local codes.
OPERATING BOILER FOR THE FIRST TIME
• Check that all installation procedures have been
carried out.
• Ensure water valve is on.
• Plug boiler appropriate electrical supply and press
power button on the front of the machine marked
‘Power’.
• The “power on” light will glow green and the machine will
fill to a safe level, above the elements, before heating.
• The “Ready/Status” light will cycle two red flashes while
the machine is filling to the safe level.
• Whilst the machine is above the safe level and filling,
the “Ready/Status” light will remain blank.
• The “Ready/Status” light will glow green when the
machine is both full and up to normal operating
temperature.
• The boiler is now ready for use.
• The font is simply activated by pressing the button on
the top of the font.
NOTE: Because the boiler is electronically controlled no
priming is necessary. The element cannot switch on until
a safe level of water is reached.
23”/585mm
15.5”/395mm
2”/50mm
11.9”/303mm
* Hosing should
be trimmed to
ensure continuous
drop from font
to boiler
4.5”/114mm
Ø 1.3”/32mm
Boiler Connections to Font
Water
Power Vent
2”/50mm*
2”/50mm
* Required for ventilation
if the machine is installed
in an enclosed cabinet.
>27.6”/700mm
min 5.1”/
130mm*
6.1”/
156mm
23”/585mm
>27.6”/700mm
15.5”/395mm
2”/50mm
15.7”/400mm
11.6”/
295mm
18.5”/470mm
Front of Font
14.6”/370mm
6.5”/165mm
Water
Power
Vent
Boiler Connections to Font
min 5.1”/
130mm*
* Hosing should
be trimmed to
ensure continuous
drop from font
to boiler
2”/50mm*
2”/50mm
* Required for ventilation
if the machine is installed
in an enclosed cabinet.
23”/585mm
>27.6”/700mm
15.5”/395mm
2”/50mm
15.7”/400mm
11.6”/
295mm
18.5”/470mm
Front of Font
14.6”/370mm
6.5”/165mm
Boiler Connections to Font
Water
Power Vent
min 5.1”
/130mm*
* Hosing should
be trimmed to
ensure continuous
drop from font
to boiler
2”/50mm*
2”/50mm
* Required for ventilation
if the machine is installed
in an enclosed cabinet.
Front of Font
14.6”/370mm
6.5”/165mm
Boiler Connections to Font
Dispense 1
Font #1 Connection
Vent
Dispense 2
Font #2 Connection
19.4”/495mm
2”/50mm
26.2”/667mm
min 5.1”/130mm
15.7”/400mm
11.6”
/295mm
* Hosing should
be trimmed
to ensure
continuous
drop from font
to boiler
18.5”/470mm

This manual suits for next models

7

Other Marco Water Dispenser manuals

Marco FRIIA HCS User manual

Marco

Marco FRIIA HCS User manual

Marco ECOBOILER UC4 User manual

Marco

Marco ECOBOILER UC4 User manual

Marco 1001866US User manual

Marco

Marco 1001866US User manual

Marco 5001862US User manual

Marco

Marco 5001862US User manual

Marco FRIIA Lite CS 5000206 User manual

Marco

Marco FRIIA Lite CS 5000206 User manual

Marco FRIIA HC 5002868US User manual

Marco

Marco FRIIA HC 5002868US User manual

Popular Water Dispenser manuals by other brands

H2OPTIMO H2O-CS-ECO Technical manual

H2OPTIMO

H2OPTIMO H2O-CS-ECO Technical manual

GE GXCF03EWWR owner's manual

GE

GE GXCF03EWWR owner's manual

Hellenbrand Iron curtain System 2.0 owner's manual

Hellenbrand

Hellenbrand Iron curtain System 2.0 owner's manual

Kärcher WPD 100 Basic manual

Kärcher

Kärcher WPD 100 Basic manual

Honeywell HWBL1033 Series owner's manual

Honeywell

Honeywell HWBL1033 Series owner's manual

WaterLogic ICE 900 Supplemental service manual

WaterLogic

WaterLogic ICE 900 Supplemental service manual

USTM WS-12-C-1650 Manual instruction

USTM

USTM WS-12-C-1650 Manual instruction

Elkay EDF20 Installation, care & use manual

Elkay

Elkay EDF20 Installation, care & use manual

Aqua EQUO SOFT Programming manual

Aqua

Aqua EQUO SOFT Programming manual

entegris Chemlock PFA Installation and use manual

entegris

entegris Chemlock PFA Installation and use manual

Elkay VRC8WS Installation, care & use manual

Elkay

Elkay VRC8WS Installation, care & use manual

Haws 3202G Installation, operation & maintenance instructions

Haws

Haws 3202G Installation, operation & maintenance instructions

Carel ROC025500N user manual

Carel

Carel ROC025500N user manual

LifeMist 0011 Series owner's guide

LifeMist

LifeMist 0011 Series owner's guide

Simfer SB2602 user manual

Simfer

Simfer SB2602 user manual

Elkay OBFAVR8*1E Installation, care & use manual

Elkay

Elkay OBFAVR8*1E Installation, care & use manual

Event Furniture 18030 Operating & safety guide

Event Furniture

Event Furniture 18030 Operating & safety guide

HENDRX HR-90HK manual

HENDRX

HENDRX HR-90HK manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.