18 19
Problems Possible Causes Corrective Actions
1. Inlet and outlet
fittings leaking A. Fittings not tight
B. Rubber washer worn-out A. Tighten fittings.
B. Change rubber washer.
2. Blank screen A. Power not connected.
B. LCD damaged.
C. LCD not connected to PCB.
A. Connect power to the unit.
B. Change LCD.
C. Connect LCD to the PCB Board.
3. Functional keys not
working A. No water output.
B. Water flow is too low.
C. Key or PCB damaged.
A. Check water supply valves.
B. Open valve to increase flow.
C. Change key or PCB.
4. Water too hot A. Temperature setpoint too high.
B. Water flow is too low. A. Set a lower temperature.
B. Open valve to increase water flow.
5. Water too cold A. Low temperature set.
B. Too much waer flow. A. Set a higher temperature.
B. Reduce water flow.
6. Outlet flow noticeably
decreases Inlet strainer or shower clogged. Clean strainer and shower.
7. LED displays E1 Outlet temperature is over
67 deg «C» /153ºF. A. Reduce the temperature.
B. Turn up the water flow.
8. LED displays E3 Temperature sensor failure. Please contact with the local dealer.
9. LED displays E4 Dry Heating. Shut off. Clean all outlets from any
debris, dirt, any particle or scale inside
the pipe.
10. Pressure relief
valve releases water A. Outlet blocked.
B. Inlet pressure over 100psi or 0.7Mpa. A. Clean shower set.
B. Reduce water pressure.
11. Display overflow Inlet water flow is too high. Reduce the inlet water flow.
WARNING: Corrections to problems 8, 9 and 10 should only be performed by
qualifiedelectricianor plumber. Thepersonwho initially installedtheunit is thebest
onetocontactforhelp,orcontactMareyforservice.
2.Turnonthecircuitbreakerstoprovidepowertotheunit.
3. Press the center button to turn on the heater. NOTE it will not start heating until
waterisprovidedtotheunit.
If there is power to the unit, but no digital display, turn off the circuit breaker. Double
check to make sure that the cable to the LCD panel on the front cover is correctly
connectedinsidetheunit,thenturnthebreakerbackon.
4. After the unit is supplied with power, a beep sound can be heard and the display
flashestheset temperature, then goessolid showing the actualoutput temperature
for30secondsuntilthescreengoesblank.theunitisnowinstandbymode.
5. Press the power button to activate/ deactivate the unit. When the unit is ON, the
LEDdisplayshowstheactualwatertemperatureoftheoutletwater.
6. The outlet water temperature can be adjusted by changing the temperature
settings on the heater. Press and to adjust the temperature. The range of
optionsforthetemperaturesettingis30ºC-52ºC/86ºF-125ºF.
WARNING: If the unit has been used recently, you may initially get a short burst of
veryhotwaterfromtheunit.Allowafewsecondsforthewatertocooldowntotheset
point. Test the water before you take a shower. If the unit will not be used during
winter,drainoutanywatercompletelysothattheheaterwillnotfreeze.
Periodically clean the inlet filter screen and the shower head to maintain strong
waterflow.
7. Press thenpress toconvertthe temperature displaybetweenFahrenheit
andCelsius.
8. The unit features an automatic memory function to avoid repetitive operation.
When you turn on the water heater, the default set point will be the same as the last
settingused.