7.Verifythatyouhaveyourwatersupply(waterinlet)andshowerhandle(wateroutlet).
Waterflowsthroughthe unit,butthereisnohotwatercomingout
1. New batteries are required for ignition spark. Verify that the batteries aligned in the
proper polarity (+/-). Check the battery case cap for instructions on how to install the
batteriesproperly.
2.Checkthatthewaterpressureis,atleast,5PSI,sustained.
3. Ensure that the Liquid Propane regulator is threaded all of the way on to the unit and
thatyouhaveanadequategasinyourpropanebottle.
4. Verify that you have hooked up the outgoing water supply and the incoming water
supply properly. The shower head should be attached to the outgoing water(located at
the center) and the water supply should be attached to your incoming connection
(locatedonthefarright).
Thewateriscomingoutwarm.
Thewateriscomingoutwarm
1.Checkifthereisablueflamebylookingontheviewerpane. Ifyouseeayellowflame
it could be a cracked gas regulator. Please call Marey Heaters Corp directly if this
happens,donotattempttouseit.
2. The unit is being operated at an altitude above the 6,000 feet. The unit has been
tested at altitudes of more than 7,000 feet but we only recommend using it below an
elevationsof6,000feet.
Unitstartsfora shortamountoftimeandthenshutoff
1. Check that the thermocouple is able to complete the circuit by checking that is
flushedwith thehole inthe heatexchanger.Thisispossibly occurringbecause iseither
tooloworhightocompleteit.
2.Lookifthegassensorshavecomelooseorcheckthatisproperlyconnected.
3. If you run out of gas, if you have low gas, or if your Propane gas cylinders are
contaminated with air (especially new tanks upon their first filling), than Cycle the unit
on and off by using the shower head switch several times (5) to purge the air from the
gas.
4.Strongwinds.
5. This unit activate at a sustained water pressures of 5-145 PSI. If your house water
pressure is below the minimum the unit will not activate. You will need a sustained
waterpressureofapproximately40-60PSIforadequateuse.
DearCustomer,
You have 30 days from your purchase date to register in Marey Heater Warranty
Program in our web site www.marey.com. Registration after 30 days voids
Warranty.Warrantyappliesonlydueto manufacturing defects.Damagecaused
by customer due to a bad installation, exposure to extreme climate conditions,
heaters with broken seal or unarmed interior are not covered by warranty. We
highlyrecommendyouto install your unit according to the Instructions Manual and
withaspecializedplumber/electrician.
Marey warranty cover parts and labor during its lifetime. The warranty does not
coverreimbursement.
Iftheheater undergoes any changes under warranty and had been repaired within
thisperiod,itisyourresponsibilitytocontactMareytonotifythenewserialnumber.
5YEARSWARRANTYCOVERAGE
MareyHeaterguaranteesthiswaterheatertotheoriginalownerofthewaterheater
at the original installation location against defects in material for the periods
specifiedbelow.
WARRANTYPERIOD
1stmonthofpurchase:coverparts,laborandshippingbackandforth.
1st year of purchase: cover parts and labor. Customer should ship the unit to
MareyHeaterCorpCentralServicesinPuertoRicoinordertogetitrepaired.
2nd to 5th year of purchase: coverparts.Customer should ship the unit to Marey
HeaterCorpCentralServicesinPuertoRicoinordertogetitrepaired.
Note: Damage caused by exposure to freezing conditions is not covered by the
warranty.
Note:Damagecausedbyscaleformationisnotcoveredbythewarranty.
-EXCLUSIONS
1. THIS LIMITED WARRANTY SHALLBE THE EXCLUSIVE WARRANTYMADE
BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED (WHETHER WRITTEN OR ORAL),
FOROTHERSELLERSORDISTRIBUTORS.
2. Manufacturer shall not be liable for incidental, consequential, special or
contingent damages or expenses arising, directly or indirectly, from any defect in
thewaterheaterortheuseofthewaterheater.
1110