TWILIGHT SWITCH
type TS-31-2-G.4
User manual
I. Purpose
The TWILIGHT SWITCH TS-31-2-G.4 is designed to automatically turn on the receiver at a certain (set) light
intensity and turn it off when the light intensity is twice as high, or vice versa (NO and NC contacts). It is used
for receivers switched on and off at high illuminance (100 ..... 100,000lx). Mounting on a vertical surface,
outdoors, in the sunlight. Protection degree IP65.
II. Features of TWILIGHT SWITCH TS-31-2-G. 4
>> high switching power 16A (4000 W) 250VAC, 16A (384 W) 24VDC
>> high inrush current (resistance to 100 A surge current)
>> freedom of connections:
> executive relay contacts (one normally open contact - NO, one normally closed contact - NC) galvanically
separated, which allows connections in various configurations
>> precise logarithmic regulation:
> 100 ... 1,000 lx - standard, advertising on / off, etc.
> 1,000 ... 10,000 lx - range of switching on / off blinds, roller shutters, etc.
> 10,000 ... 100,000 lx - range of switching on / off of photovoltaic installations (solar), etc.
>> traffic light (LED) with operating status (fig. 2):
> LED-1 - indication of 230V supply voltage on terminals 1,2
> LED-2 - relay switching signalling - terminals 3,4,5 (short circuit 3,4, opening 4,5)
> LED-3 - internal signalling (without delay) of exceeding the set lighting threshold
> LED-4 - external relay switching indication (short circuit 3,4, opening 4,5)
>>. convenient installation:
> two stainless screws, with expansion bolts, for wall mounting (included)
> cover fixed with four stainless screws
> two PG-13.5 glands for cable entry.
A specialized relay is used in the TS-31-2-G.4 TWILIGHT SWITCH
G2RL-1-E-HR by OMRON, designed to switch various lighting lamps. The special design enables effective
switching of lamps with an inrush current of up to 100 A per pulse.
Fig.3.: Template for drilling holes for installing
the TS-31-2-G.4 TWILIGHT SWITCH
V. Repair and maintenance
All repairs of the TWILIGHT SWITCH TS-31-2-G.4 are performed by the manufacturer. The device does not
require any maintenance. When the sensor becomes contaminated, clean it with a clean, damp cloth. The
device does not require any additional maintenance.
VI. Warranty Card
The manufacturer guarantees the correct operation of the TS-31-2-G.4 TWILIGHT SWITCH. The warranty
period is 36 months from the date of sale. The warranty is extended by the time of repair. Warranty repairs are
performed by the manufacturer free of charge after the AUTOMAT is delivered to the manufacturer. Improper
use of the device or independent modifications to it will void the warranty.
84 mm
Made in Europe
www.mart-electronics.eu
In order to protect the environment, do not throw away used electrical appliances
and electronics together with municipal waste. Used equipment should be delivered to
collection points for recycling free of charge. Any information on this can be obtained
at sellers, distributors, manufacturer or on the Internet. The product's packaging is made of
ecological materials. The PVC packaging tape will be used while stocks last.
The TS-31-2-G.4 TWILIGHT SWITCH meets the requirements of the European Union
Directives
- Directive LVD 2014/35/EU - Low Voltage Directive of 26 February 2014
- Directive EMC 2014/30/EU - Eletromagnetic Compatibility Directive of 26 February 2014
3-YEAR
WARRANTY
LED-1 LED-2
LED-3
LED-4
Fig. 2. Diagrams and description of cable connections, visible
after removing the cover.
Dashed line - the receiver does the opposite.
IV. Technical data
Rated supply voltage LN
Rated frequency
Maximum load current (power):
> resistive load
> incandescent lamps
> halogen lamps
> fluorescent lamps
> energy-saving lamps and LED
Instantaneous inrush current
Rated power consumption
230V AC, + 10%, - 15%
50Hz
8A (2000 W)
8A (2000 W)
8A (2000 W)
100A
10A (2500 W)
16A, AC1 ( 4 000 W)
1,1W
Logarithmic control range
Hysteresis
Switch-on and switch-off delay
Mechanical durability
Protection level
Working temperature
Dimensions
Weight
Connecting cable
Wall plugs (drill Ö6mm)
Spacing mounting holes
Working position
Meethod of assembly
100...1 000...10 000...100 000 lx
E = 2E
30s (± 20%)
100 000 operations
IP 65
-25...+50 °C
87 x 65(90) x 44 mm
100g
2 x PG-13,5
6mm x 30 mm
84 mm
vertical
surface mounted with two screws
OFF ON
Executive contacts 1 x NO, 1 x NC
III. Assembly
The TS-31-2-G.4 TWILIGHT SWITCH can only be connected by a person authorized to operate electrical
installations. Remember to choose the right protection.
The housing is adapted for easy and quick fixing to the surface with two screws (stainless screws with
expansion plugs are included in the set).
Before installing the TWILIGHT SWITCH, remove the cover by unscrewing the four mounting screws. After
removing the cover of TS-31-2-G.4 TWILIGHT SWITCH mounting clamps 1, 2, 3, 4, 5, description of electric
wires connection and a knob for setting the activation threshold are available - Fig. 2
To facilitate the assembly, the manual includes a template that facilitates drilling the mounting holes - Fig. 3.
After installing the TS-31-2-G.4 TWILIGHT SWITCH on a vertical wall, do the following:
1.With the power supply disconnected, connect the wires in accordance with the instructions
2.switch on the supply voltage - LED-1 will light up at terminals 1, 2
> to check if it works properly, set the threshold using a screwdriver, and when it remains
current illumination level is exceeded, LED-3 lights up (without delay). After about ...... 60s
the executive relay will switch over, which will be signalled by LED-2 and LED-4
3. Using the scale, set the desired threshold value with the potentiometer knob, with a screwdriver
attached
4.After checking, close the lid carefully with the four fixing screws,
5. check the operation of the TS-31-2-G.4 TWILIGHT SWITCH machine in real conditions and possibly
correct the setting.
In order to limit the impact of temporary large changes in lighting e.g., car lamps, lightning, etc. on the
operation of the AUTOMATIC, a delay of approx. 60s has been applied.
To check the operation of the TS-31-2-G.4 TWILIGHT SWITCH during the day, after its correct installation in
accordance with the instructions, cover the sensor so that LED-3 lights up and wait approx. 60s until the
TWILIGHT SWITCH turns on the receiver. When setting low values ?
?
(100 lux), remember that on a sunny day,
covering the sensor with your bare hand may not be sufficient. Then the TWILIGHT SWITCH should be
covered more effectively.
The diagram of the TWILIGHT SWITCH operation is shown in Fig. 1.
.
NOTE: Avoid installing the TS-31-2-G.4 TWILIGHT SWITCH directly in the light stream of the lamp, because
lighting with the TS-31-2-G.4 TWILIGHT SWITCH lamp may interfere with operation - the lamp will turn on and
off cyclically from evening until morning.
t
E
ON OFF
lx
10 100
11000
Fig. 1 .: Diagrams of the operation principles of the
TS-31-2-G.4 TWILIGHT SWITCH.
L
N
1 2 345
L
N
1 2 34 5
~
16A 250VAC
(peak 100A)
16A 250VAC
(peak 100A)

Other Mart Switch manuals

Mart TS-21 User manual

Mart

Mart TS-21 User manual

Mart TS-42-3 ECO User manual

Mart

Mart TS-42-3 ECO User manual

Mart TS-42-4 ECO User manual

Mart

Mart TS-42-4 ECO User manual

Popular Switch manuals by other brands

Gewiss RESTART RD manual

Gewiss

Gewiss RESTART RD manual

ANTAIRA LNP-0702G-SFP-24 Series Quick installation guide

ANTAIRA

ANTAIRA LNP-0702G-SFP-24 Series Quick installation guide

NetComm NP2624M user guide

NetComm

NetComm NP2624M user guide

Digga Torque Hub Installation, Operating and Troubleshooting Manual

Digga

Digga Torque Hub Installation, Operating and Troubleshooting Manual

Cabletron Systems SEHI100TX-22 user guide

Cabletron Systems

Cabletron Systems SEHI100TX-22 user guide

MuxLab 500441 installation guide

MuxLab

MuxLab 500441 installation guide

Moeller T8-3-8212/E/HI12 installation instructions

Moeller

Moeller T8-3-8212/E/HI12 installation instructions

Compaq 400338-001 user guide

Compaq

Compaq 400338-001 user guide

Cisco ME 3400 Hardware installation guide

Cisco

Cisco ME 3400 Hardware installation guide

Digital Equipment MultiSwitch 700 user guide

Digital Equipment

Digital Equipment MultiSwitch 700 user guide

ZMODO Pivot Full manual

ZMODO

ZMODO Pivot Full manual

ADPRO VM22A Installation & user manual

ADPRO

ADPRO VM22A Installation & user manual

Siemens ASC10.51 Mounting instructions

Siemens

Siemens ASC10.51 Mounting instructions

Siemens RUGGEDCOM RS1600 installation manual

Siemens

Siemens RUGGEDCOM RS1600 installation manual

Manhattan 153522 user manual

Manhattan

Manhattan 153522 user manual

Allied Telesis AT-8624T/2M, AT-8624PoE Installation and safety guide

Allied Telesis

Allied Telesis AT-8624T/2M, AT-8624PoE Installation and safety guide

Allied Telesis AT-x550-18XTQ installation guide

Allied Telesis

Allied Telesis AT-x550-18XTQ installation guide

Nvidia QM87 Series user manual

Nvidia

Nvidia QM87 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.