ASADA, NISSIN, AICHI, 470-0194 JAPAN
NOTE
2N·m(21kgf·cm)
F-type connector
●Tightening torque
Wood Screws (2pcs.)
Wooden Wall
(Thickness of 10mm or more)
After connecting with cable, install splitter on wooden wall
with the two wood screws attached to the splitter itself.
This splitter is indoor use only.
Please refrain from using this splitter outdoors.
VHF UHF
2-way Splitter
2SPFAD
Satellite
15V DC
DFMTD
Satellite
VHF UHF
Wall Outlet
(Power Insertion Type)
VHF・UHF/Satellite Separator
SR2TL2-P
15V DC
Satellite
VideoAudio
VHF・UHF
15V DC
TV
Satellite Receiver
VHF・UHF/Satellite Mixer
VHF・UHF
Mixer
For satellite reception, use units and
cables which meet the performance
requirements for the satellite frequency
range.
DFMTD
(Power Insertion Type)
Satellite
VideoAudio
VHF・UHF
15V DC
TV
Satellite Receiver
VHF・UHF/Satellite Separator
SR2TL2-P
15V DC
Wall Outlet
15VDC
IN
OUT OUT
Cut off the tip of the
center conductor at
an angle to prevent
incomplete contact.
The center conductor is covered
with white film. Be sure to remove
it for better conductivity.
1.Pass the ferrule through the cable.
2.Fold back the copper braids.
3.Push the plug in firmly.
Fold back the
copper braids.
Aluminum foil
Ferrule
plug
plug
Completed
Ferrule
Cable
1mmorless
Ferrule
2mm
A
bent
center
conductor
may
cause
short
circuit
and
malfunction.
Complete Drawing
Straighten
the
center
conductor.
When aluminum foil comes off
Push and turn the plug in the cable
gently so that the plug turns the
aluminum foil in the same direction
it is coiled, and be sure to keep the
aluminum foil inside the plug.
In addition, be sure to remove
any shreds of aluminum foil.
Press firmly at the foot of the plug
so that it does not come out.
Center conductor Center conductor
Make sure the length of the
center conductor is 2mm.
Excessively long center conductor
may damage connector and will
cause malfunction.
Actual size
4
9mm
1 Cable processing 2 Mounting the plug 3 Pressure bonding of ferrule
MASter of PROduction 2K56-071CY(B)・78-5071-1L
2
F-type connector, provided as accessory, is for 5C cables.
AUG., 2007
How
to
Install
F-type
Connector Installation
Example
Power Passing Capacity
0.8A at 15V DC