Maxell Software
Display
When in ‘automatic mode’, the Maxell CM reader automatically detects the presence of a cartridge,
reads its memory chip, and displays the data.
Save
e ‘save file’ function allows you save the CM contents in a file.
Save Cartridge History
e ‘Save Cartridge History’ function reads the CM and saves its contents in a file. is function
allows you to rapidly read and save the CM contents of many cartridges.
If you scan a cartridge that has been previously scanned, the Maxell software automatically finds
and appends the previously saved file, allowing you to easily build a complete performance record
for each cartridge.
Open
Opens and displays previously saved files. When more than one file is selected, the software
performs a statistical analysis and displays statistical data including maximum, minimum, average,
and standard deviation from the selected files.
Regardless of the number of cartridges you evaluate, unacceptable cartridges will immediately be shown.
Summary Screen
e display gives you the
information you need. Values
that are outside acceptable
norms are highlighted in
order of severity in yellow,
orange, and red colors.
Maxell Score and Summary
Errors that occurred within the
last four times the cartridge was
loaded are known as “recent
errors”. Because of their
importance they are displayed
rst and are weighted higher
than other errors in calculating
MaxellScore.
Error summary for entire
cartridge
Summary Screen
When the saved results of several cartridges are selected, the Maxell
software displays the summary information of all tapes plus
additional statistical information, which includes the minimum, the
maximum, the average, and the standard deviation of all values.
Click on a value (on MaxellScore, for example) and the table is
sorted for this value. Cartridges that do not meet your standard can
immediately be identified and discarded.
Usage History Screen
Scanning a cartridge periodically with the "Save Cartridge
History" option enabled, creates a complete record of the
cartridge. e example above shows a cartridge record with 8
scans. Notice the change of MaxellScore. (82 to 76)
Scanning a cartridge periodically is the best way to track its
performance and detect the time when the cartridge should be retired.
e graph below is derived from the MaxellScore row in the "Usage
History" page of a cartridge that has been scanned periodically.
The red vertical line
shows the point when
the cartridge should
be retired.
Hardware & Software
Requirements
The Maxell CM reader can be connected to
most systems. All you need is a USB port. The
Maxell application software runs under all
recent Windows operating systems.
Item # 183100
UPC 0-25215-9099-0