Maximum Controls MAX WIEGAND User manual

www.max.us.com
www.max.us.com
MAX.US.COM
12-21-20 _Rev 2.9
QUICK INSTALLATION GUIDE
MAX WIEGAND CONVERTER
RESIDENTIAL / COMMERCIAL APPLICATION
Timers Diagnose Users Settings
GATE STATUS: OPEN, OPENING, CLOSED
CLOSE
OPEN
LAGUNA WOODS GATE
GATE
RELEASE
Max Cloud App
Max Wiegand Converter
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
Max Operator
Max Cell Hub

2
www.max.us.com
www.max.us.com
Max Wiegand Converter
TABLE OF CONTENT
Max Wiegand Converter
Overview
Pedestrian Door Application
Entry Gate Application
Pedestrian Door Application - wireless
Entry Gate Application - wireless
Program Wiegand Keycodes with time restrictions
www.max.us.com
www.max.us.com
MAX WIEGAND CONVERTER OVERVIEW
2
3
5
6
7
8
WIEGAND PORT
• To support 26-bit card readers, radio
receivers & RFID transponders
• Program cards/keyfob, radio transmitters
& transponder tags via Max Cloud App and
assign optional time restrictions
• Track wiegand device activity in event log
RELAY PORT
• Control access point with
dedicated relay
ACCESS PT
Rotary switch to
select access point #
REQUEST TO EXIT RTE PORT
• Supports exit switch request
on pedestrian gates
RS
COMM PORT
• To connect to
Max Cell Hub
STATUS LEDs
• Each port has indicator LEDs
for easy troubleshooting
POWER IN: VDC / VAC
Max Wiegand Converter requires a Max Cell Hub.
Both work exclusively with Max Gate Operators

12-21-20 _Rev 2.9 3
www.max.us.com
www.max.us.com
MAX OPERATOR
MAX CELL HUB
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
D1
GND
GND
D0
Card Reader
1Wiring Hub to
Wiegand Converter
Connect RS-485 port of Max
Cell Hub to RS-485 port of Max
Wiegand Converter
(+) to (+)
(-) to (-)
GND to GND
2
3
Wiring Power Input
Wiring Wiegand device
Connect 12VDC, 1A
power transformer to
Power Input port of
Max Keypad
(polarity does NOT matter)
Connect wiegand
device as shown
GND
+12V
PEDESTRIAN DOOR
Max Card Reader
Max Wiegand Converter
PEDESTRIAN DOOR APPLICATION
USING WIEGAND CONVERTER
(+)
(+)
(-)
(-)

4
www.max.us.com
www.max.us.com
SOLENOID LOCK
Gnd
NO
Power
EXIT PUSH BUTTON
PRESS
to EXIT
RTE
GND
GND
5
4
6
Wiring Solenoid Lock
Wiring Exit Push Button
Install Solenoid Lock as is shown
Install request to Exit
Push Button as shown
Select "Access PT#"
using rotary switch
NO COM
(+)
(-)
PEDESTRIAN DOOR APPLICATION
USING WIEGAND CONVERTER
PEDESTRIAN DOOR
Select #1-14: to open
gate using Keypad relay

12-21-20 _Rev 2.9 5
www.max.us.com
www.max.us.com
GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
Wiegand
Receiver
+12V
GND
EXIT PUSH BUTTON
PRESS
to EXIT
Transponder
Transponder
OR
5Wiring Power Input
Connect 12VDC, 1A
power transformer to
Power Input port of
Max Keypad
(polarity does NOT matter)
4Wiring Wiegand device
Connect wiegand
device as shown
3Wiring Hub to
Wiegand Converter
Connect RS-485 port of Max Cell Hub to
RS-485 port of Max Wiegand Converter
(+) to (+)
(-) to (-)
GND to GND
2Wiring Exit Push Button
Install request to Exit
Push Button as shown
MAX OPERATOR
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
1Select "Access PT#"
using rotary switch
RTE
GND
GND
GND
ENTRY GATE APPLICATION
USING WIEGAND CONVERTER
(+)
(+)
(-)
(-)
D1
D0
Select #0: to open gate via Cell Hub
(note: keypad relay NOT activated)
Select #15: to open gate via Cell Hub
(note: keypad relay is also activated)

6
www.max.us.com
www.max.us.com
7
3
8
Wire Wiegand
device to Slave
Wiegand Converter
Connect wiegand
device as shown
Slide switch
to WIRED
on Master
Slide switch to
WIRELESS
on Slave
PEDESTRIAN DOOR
ENTRY GATE APPLICATION
USING WIRELESS MAX WIEGAND CONVERTER
ENTRY GATE APPLICATION
USING WIRELESS MAX WIEGAND CONVERTER
PEDESTRIAN DOOR APPLICATION
USING WIRELESS MAX WIEGAND CONVERTER
1Wiring Hub
to Master
Wiegand
Converter
Connect RS-
485 port of Max
Cell Hub to
RS-485 port of
Max Wiegand
Converter
(+) to (+)
(-) to (-)
GND to GND
Up to 1 mile range
direct line of site
5
4
Install Selenoid
Lock as shown
Install Push
Button as
shown
2
6
Wiring
Power
Input
Connect
Power
Input
Connect 12VDC,
1A power
transformer to
Power Input port
of
Max Wiegand
Converter
(polarity
does NOT matter)
One master wireless Max Wiegand
Converter can communicate with
up to 16 slave units
MAX OPERATOR
MAX CELL HUB
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
GND
GND
D0
Card Reader
GND
GND
+12V
+12V
Wireless Max
Wiegand Converter
Wireless Max
Wiegand Converter
MASTER
SLAVE
(+)
(+)
(-)
(-)
RTE
GND
PRESS
to EXIT
NO
COM
Gnd
NO
Power
(+)
(-) GND
SOLENOID LOCK
D1

12-21-20 _Rev 2.9 7
Slide switch
to WIRED
on Master
Transponder
www.max.us.com
www.max.us.com
ENTRY GATE APPLICATION
USING WIRELESS MAX WIEGAND CONVERTER
ENTRY GATE APPLICATION
USING WIRELESS MAX WIEGAND CONVERTER
1Wiring Hub
to Master
Wiegand
Converter
Connect RS-
485 port of Max
Cell Hub to
RS-485 port of
Max Wiegand
Converter
(+) to (+)
(-) to (-)
GND to GND
5
3
6
Wire Wiegand
device to Slave
Wiegand Converter
Connect wiegand
device as shown
Up to 1 mile range
direct line of site
MAX CELL HUB
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
D1
GND
GND
D0
GND
GND
+12V
+12V
Wireless Max
Wiegand Converter
Wireless Max
Wiegand Converter
(+)
(+)
(-)
(-)
Wiegand
Receiver
Transponder
OR
2
4
Wiring Power Input
Connect
Power
Input
Connect 12VDC, 1A
power transformer to
Power Input port of
Max Wiegand Converter
(polarity does NOT matter)
MASTER
SLAVE
Slide switch
to WIRELESS
on Slave
One master wireless Max Wiegand
Converter can communicate with
up to 16 slave units

8
www.max.us.com
www.max.us.com
1
2
3
4
Press Users icon in the
main menu
Then Press Add a User in
the following menu
Enter Name of your visitor
Program Wiegand Keycode
Enter Facility and Wiegand
Keycode for the transmitter,
keyfob or tag
User Name
PROGRAM WIEGAND KEYCODES
WITH RESTRICTIVE TIME ZONES
Rose
Facility Wiegand Keycode
123 12345

12-21-20 _Rev 2.9 9
www.max.us.com
www.max.us.com
PROGRAM WIEGAND KEYCODES
WITH RESTRICTIVE TIME ZONES
5Assign a timer for wiegand
keycode (OPTIONAL)
If you choose No Timer
wiegand Keycode has no time
restriction
Choose one of six timer
schedules
Watch video tutorials from
Max Cloud App, just go to
the home screen
Watch video
tutorials from Max
Cloud App, just go
to the home screen
Applying restrictive time period to
keycodes improves the security to
your gate site
6Press the back button [<] on the top left of the screen to confirm
create a user
Timer
OR SCAN CODE
to watch tutorial

CARD
READER
Max Wiegand Converter Max Wiegand Converter Max Wiegand Converter
RS485 COMM LINK
Access Point # 1Access Point # 2Access Point # 3
Max Cell Hub
RADIO
RECEIVER
RFID
Transponder
• Wiegand Keycodes with optional time zone restrictions
• Keypad Keycodes with optional time zone restrictions
• Virtual Transmitters (App Users) with optional time restrictions
• Guest Passes with date and time restrictions
• Auto Open / Close Timer to set daily recurring schedule for gate operator
• Text Alerts on App for gate status, gate tamper and sensor fail events
EVENT LOG to track gate site events on App. Events tracked includes:
- Max Cloud App OPEN commands
- Guest Pass OPEN commands
- Keypad keycode entries
- Wiegand keycodes scans
- All programming changes
ERROR LOG to monitor and diagnose gate operator issues remotely
MAX CELL HUB
POWER
COMM
LINK
ONLINE
CELL
LINK
RS485
5V
(-) (+) GND
www.max.us.com
www.max.us.com
10530 Lawson River Ave., Fountain Valley, CA 92708
(949) 699-0220 |maxsales.us@gmail.com |MAX.US.COM
QUICK INSTALLATION GUIDE
MAX WIEGAND CONVERTER
RESIDENTIAL / COMMERCIAL APPLICATION
Max Hub can support up to 16 access points
using Max Keypads and/or Max Wiegand Converter Units
INTEGRATED ACCESS CONTROLINTEGRATED ACCESS CONTROL
Timers Diagnose Users Settings
GATE STATUS:OPEN, OPENING, CLOSED
CLOSE
OPEN
LAGUNA WOODS GATE
GATE
RELEASE
Other manuals for MAX WIEGAND
1
Other Maximum Controls Media Converter manuals