Page 2 (of 6)
ON
LEDsOFF
After 15
minutes
#4
.
#5
.
Detection
Range Setting
Auto Night
Detection mode
DIP SWITCH SETTING
#2
.
Pulse Count42
Low High
Anti-masking
Sensitivity and
Learning,
and Detection
Technology
Combination
OR
AND
#3
.
Physical
setting,
by
Trimmers
Setting
by "Walk
Test"
LowHigh
Microwave and PIR sensitivity
adjustment
High
Microwave
Sensitivity
Adjustment
PIR
Sensitivity
Adjustment
High
ON
OFF
DIP Switch Specifications
DIP Switch #1,LED indication: ON or OFF (when switching to OFF, the LED indication will be
enabled for 15 minutes- in order to allow "walk test".
DIP Switch #2,Pulse Count: Select between 2 or 4 pulses.
Choose 2 pulses in a place with a low risk to false alarm.
Choose 4 pulses in a place with a high risk to false alarm.
DIP Switch #3,Anti-masking Sensitivity and Learning, and Detection Technology Combination:
a. Select between LOW and HIGH Anti-masking Sensitivity.
Choose LOW Anti-masking Sensitivity in a place suffering of dust.
Choose HIGH Anti-masking Sensitivity in a place that doesn't suffering of dust.
b. Learning: Once the state of the DIP switch is changed, OUT-LOOK learns the environmental conditions
of its protected area (refer to page No.6).
c. Select AND if you wish a true alarm will be generated just when the intrusion is detected by both
detection technologies (PIR AND Microwave).
Select OR if you wish a true alarm will be generated when the intrusion is detected by one of two detection
technologies (PIR OR Microwave).
Remark: the detection technology combination OR is valid just when OUT-LOOK detected that its near
field-of-view is masked/covered (Anti-masking). Otherwise, the detection technology combination is AND.

OUT-LOOK Outdoor/indoor intrusion detector
Preliminary Quick Reference
Ver.1 28/05/2008
Page 3 (of 6)
DIP Switch #4,Detection Range Setting.
There are two ways to set the detection range:
a. Physical setting by the Trimmers, allows you to set the detection range manually- by the described
above PIR and Microwave Trimmers.
b. Setting by a "Walk Test", allows you to set the detection range automatically- by moving in the
protected area ("Walk test"). Valid just if the required detection range is above 3 meters.
The adjustment of the PIR and Microwave Trimmers must be carried out before the Setting by a "Walk
Test".
Here is who to set the detection range automatically, by a "Walk Test":
1. Once you move DIP switch No. 4 from OFF to ON position, the Red, Green and Orange will glow.
2. Close the detector's case immediately and go to the most distant point of the desired detection range (Not
over the detector's maximum detection range limitations!) and wait there, for a few seconds, until the
Green LED will glow alone.
3. Once the Green LED glows (alone), you should define the detection range borders by walking parallel to
the detector's front to the most distant points of the desired detection range, while obey these easy
instructions provided by detector's LED indicators:
GreenWalk!
RedStop!
That "Walk/Stop" procedure will repeat 4 times.
5. As an indication for the end of procedure, the Green and Red LED indicators will glow for 8 seconds.
DIP Switch #5,Auto Night Detection Mode.
Set to "ON" if you wish during night (darkness) the detection range will be automatically shifted to a
different detection range.
If DIP switch No. 4 is set to Setting by "Walk Test" position,
Then:
- During the day (light) the detection range is as defined in the "Walk Test".
- Once the night (darkness) comes, the detection range defined by the PIR and Microwave Trimmers.

OUT-LOOK Outdoor/indoor intrusion detector
Preliminary Quick Reference
Ver.1 28/05/2008
Page 4 (of 6)
TERMINAL BLOCK WIRING
12V DC
1 2 3 4 5 6 7
8 9
RELAY
Alarm Relay
8mA @ 12Vdc
Maximum.
20mA @ 5Vdc
Maximum
CO
Input Terminal !
System Armed = 0V.
System Disarmed = 12V or Open
Please refer to page No. 5
MASK
Anti-masking
and
Vibration/Shock
Relay
8mA @ 12Vdc max.
20mA @ 5Vdc max.
TAMPER
Tamper Switch
8mA @ 12Vdc
Maximum.
20mA @ 5Vdc
Maximum

OUT-LOOK Outdoor/indoor intrusion detector
Preliminary Quick Reference
Ver.1 28/05/2008
Page 5 (of 6)
WIRING TERMINAL SPECIFICATIONS
* Terminal No. 8+9
Indicated on the circuit as: .
These are the 9V to 14V DC power supply inputs.
* Terminal No. 6+7
Indicated on the circuit as: RELAY
Represents the contacts of the “Alarm Relay”, which are Normally in Closed state N.C.
Upon detection of any human movement, the relay’s contacts will be opened for two seconds, and
both Red & Yellow LED indicators will flash.
* Terminal No. 5
Indicated on the circuit as: CO
This terminal is to be used if you wish to get a report from the detector’s memory indicating if it
has detected human movement during the armed period.
This terminal should receive an indication from the alarm system’s control panel, whether it is in
an Armed or Disarmed state.
- If 0V received, the detector “understands” that the alarm system is Armed.
- If 12V or no voltage at all received, the detector “understands” that the alarm system is
Disarmed.
How to draw and display the detector’s memory ?
If: the detector was alerted during the “armed” period,
Then: upon switching the alarm system from “Armed” to
“Disarmed” mode, the Red LED will flash for 30 minutes.
* Terminal No. 3+4
Indicated on the circuit as: MASK
Represents the contacts of the Anti-masking and Vibration/Shock Relay which are normally in
closed state (N.C.).
a. If an object blocks (masks) the detector’s near field-of-view, the Green LED will flash.
However, if an object blocks (masks) the detector’s near field-of-view for more than 40 seconds,
the green LED will glow constantly, and the "MASK” relay's contacts will be opened for at least 2
seconds and will remain opened for as long as the masking exists.
b. If someone attempts to damage or sabotage the detector by hitting, moving, turning or tilting it, the
green LED will glow constantly, and the "MASK” relay's contacts will be opened for 2 seconds.
To enable the Vibration/Shock Relay, you must short circuit between terminal No. 5 (CO) and No.
8 (-).
* Terminal No. 1+2
Indicated on the circuit as: TAMPER
Represents the contacts of the built-in TAMPER switch, which are normally in a closed state
(N.C.). The contacts will open, when the detector’s case is opened.

OUT-LOOK Outdoor/indoor intrusion detector
Preliminary Quick Reference
Ver.1 28/05/2008
Page 6 (of 6)
PREPARING THE MASKING CHANNEL FOR OPERATION (Obligatory for
proper Anti-masking operation!!!)
To enable proper operation of the masking detection (Anti-masking), it is necessary to allow the
detector to automatically study and analyze the environmental conditions of its protected area.
This is an obligatory action that should be performed by the installer, ensuring proper operation of
the Anti-masking channel!!!
Study procedure to be performed in two cases:
1. Upon connecting the power supply to the detector (after about 1 minute, the time it takes the
detector to stabilize when first fed by power supply).
2. Upon the position of DIP switch number-3 (LED indicator) is changed.
Study procedure:
- Immediately close the detector’s case (within 30 seconds maximum).
- Keep at least 1 meter away from its front part, until the study procedure is complete, about 2
minutes.
PERFORM A TEST
* To be carried out when the case is closed and the LED indicators are enabled
(DIP switch No.1 switched to ON).
Test procedure for human movement detection (Alarm):
oWalk in the protected area.
oCompulsory reaction of the detector:
Upon each detection, the “Alarm Relay” will operate for 2 seconds.
The Red+Yellow LED indicators will flash simultaneously during those 2 seconds.
Test procedure for masking detection (Anti-masking):
oAt a distance of about 10 cm from the front of the detector, place a white piece of paper (or any
other object).
oCompulsory reaction of the detector:
The Green LED will immediately flash continuously as long as the masking object exists.
If the masking object exists for more than 40 seconds, the Green LED will glow continuously
and the "MASK” (Anti-masking) relay will operate for at least 2 seconds and for as long as
masking exists.