Maxitrol GF40-1-44 Manual

1
GF60 models
GF80 models
* Dimensions (inches/millimeters) are maximums and are to be used only as an aid in designing clearance for the lter.
Actual production dimensions may vary somewhat from those shown.
GF40 models
Pipe Size NPT Model ISO 7-1 Model
1/2" GF40-1-44 GF40M-1-44
3/4" GF60-1-66 GF60M-1-66
1" GF60-1-88 GF60M-1-88
1-1/4" GF80-1-1010 GF80M-1-1010
1-1/2" GF80-1-1212 GF80M-1-1212
2" GF80-1-1616 GF80M-1-1616
Maxitrol lters are suitable for application in natural, manu-
factured, mixed gases, liqueed petroleum gases and LP gas-air
mixture piping systems.
Changes to the NFPA (National Fire Protection Association) 86
Standard require a gas lter or strainer be installed in the fuel gas
supply line, on new oven and furnace installations.
The lters are tested according to DIN 3386 and have
DIN/DVGW approval. The lters are approved according to Eu-
ropean Gas Appliance Directive 90/396/EG, Pressure Equipment
Directive 97/23/E, the Russian GOST, and the Hungarian MBVTI
requirements. Filters with NPT threads are not covered by Euro-
pean certication.
Unique lter matting effectively separates dust. The matting has
an extremely high capacity for accumulated dust due to its wide
ltering surface and depth effect. The material will not allow par-
ticulate inltration over 0.05mm (50 microns). The inserts are quick
and easy to replace.
The lter housing's compact size allows for easy
original equipment installation or retrotting.
Specications
• Housing's are made of durable cast aluminum
• Filter matting consists of polypropylene impregnated eece
• Rp or Rc thread (parallel or taper) dimensions according to
ISO 7-1. NPT thread according to ANSI.
• Maximum operating inlet pressure: 15 psi (1 bar)
• Ambient temperature limit: 175° F (80° C)
Gas Filters
½", ¾", 1", 1¼", 1½", 2" NPT or ISO 7-1
and for other applications such as air
2
Installation and Service
Maxitrol lters are suitable for multipoise mounting.
(Preferably with the lid facing down or to the side.) In-
stall the lter properly with gas owing as indicated by
the arrow on the casting. It is also important to leave
sufcient space above the cover to allow for removal
in order to change the lter insert.
Frequency of lter insert maintenance is depen-
dent upon both the maximum operating pressure of
your equipment application, and the associated pres-
sure drop at the lter. Although, it is recommended
that the lter insert be replaced at least once a year.
See the adjoining pressure drop chart.
Shut off all gas before servicing the lter insert.
When loosening the screws secure the cover, proceed
slowly in case of any residual gas pressure. Remove
the cover and withdraw the lter insert.
place the lter insert so that it abuts correctly in rela-
tion to the anges and base of the housing. The lter
insert should not extend into the area between the
o-ring and cover - slightly bend down the corners of
the matting to prevent o-ring obstruction. Replace the
cover and tighten the screws.
Check carefully for gas leaks immediately after the
lter has been installed or serviced and the gas turned
on. Do this before attempting to operate the appliance
or other gas-red device. Use a rich liquid soap solu-
tion or other accepted leak tester on the area between
the cover and housing, and at the pipe connections.
Never use if leakage is detected.
Pressure Drop Curves (0.64 sp gr gas)
Filter Replacement Material
Replacement lter matting material is available.
GF40 models - part number 101706-1
GF60 models - part number 101706-2
GF80 models - part number 101706-3
Pipe Size NPT Model ISO 7-1 Model
1/2" GF40-1-44 GF40M-1-44
3/4" GF60-1-66 GF60M-1-66
1" GF60-1-88 GF60M-1-88
1-1/4" GF80-1-1010 GF80M-1-1010
1-1/2" GF80-1-1212 GF80M-1-1212
2" GF80-1-1616 GF80M-1-1616
10 30 100 1000 2000
.3
1
10
100
3 (m3/hr)
Volumetric Flow Rate
100 (cfh) 1000 10000 100000
0.1
1
10
100
(inches W.C.)
(mbar)
Pressure Drop (rP)
GF40-1-44
GF60-1-66
FG60-1-88
GF80-1-1010
GF80-1-1212
GF80-1-1616
Replace the lter insert with the side imprinted
'Austritt' (outlet) facing the outlet. Inspect the o-ring
and replace if necessary. To ensure an effective seal,

This manual suits for next models

13

Popular Water Filtration System manuals by other brands

Aquasafe Home II COMBO installation instructions

Aquasafe

Aquasafe Home II COMBO installation instructions

Giuliani Anello 706 Series quick start guide

Giuliani Anello

Giuliani Anello 706 Series quick start guide

Pentair FULLFLOXF C Series Installation and user guide

Pentair

Pentair FULLFLOXF C Series Installation and user guide

DuPont Authentication WFFM100 Series installation instructions

DuPont Authentication

DuPont Authentication WFFM100 Series installation instructions

OptiPure QT10-2 Installation, operation & maintenance manual

OptiPure

OptiPure QT10-2 Installation, operation & maintenance manual

THRUSH AAR-O-VENT TASF Operation & maintenance manual

THRUSH

THRUSH AAR-O-VENT TASF Operation & maintenance manual

atecpool ATEC50 manual

atecpool

atecpool ATEC50 manual

Aquascape Pro Signature BioFalls 2500 Instructions & maintenance

Aquascape Pro

Aquascape Pro Signature BioFalls 2500 Instructions & maintenance

SIBRAPE MINIFILTRO 10010006 installation manual

SIBRAPE

SIBRAPE MINIFILTRO 10010006 installation manual

Elkay EFC1150D-A Installation & user manual

Elkay

Elkay EFC1150D-A Installation & user manual

Kessel Ecolift L Series Installation and operating instructions

Kessel

Kessel Ecolift L Series Installation and operating instructions

RM Italy HBF 500 quick start guide

RM Italy

RM Italy HBF 500 quick start guide

TLV DC7 instruction manual

TLV

TLV DC7 instruction manual

Good PT4000T36-GOLD Installation & service guide

Good

Good PT4000T36-GOLD Installation & service guide

Water Control Corporation MEGAbite BRASSMASTER Installation & operation manual

Water Control Corporation

Water Control Corporation MEGAbite BRASSMASTER Installation & operation manual

BWT AQA total 1500 Installation and operating instructions

BWT

BWT AQA total 1500 Installation and operating instructions

Nikken PiMag Optimiser manual

Nikken

Nikken PiMag Optimiser manual

Empire Filter Chamber Operating and maintenance instructions

Empire

Empire Filter Chamber Operating and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.