MaxLite HL-AR80 Series User manual

Operating nstructions Hazardous Location Series
MaxLite Hazardous Location Flood Light – Class Division 2
• To reduce the risk of death, personal injury or property damage from fire,
electric shock, falling parts, cuts/abrasions, and other hazards read all
warnings and instructions included with and on the fixture box and all
fixture labels.
• Before installing, servicing, or performing routine maintenance upon
this equipment, follow these general precautions.
• Commercial installation, service and maintenance of luminaires
should be performed by a qualified licensed electrician.
• DO NOT INSTALL DAMAGED PRODUCT!
• This fixture is intended to be connected to a properly installed and
grounded UL listed junction box.
• Make sure that the supply voltage is the same as the luminaire voltage.
• Do not install where the marked operating temperatures exceed the
ignition temperatures of the hazardous atmosphere.
• Do not operate in ambient temperatures above those indicated on the
luminaire nameplate.
• All gasket seals must be clean and undamaged.
WARN NG:
RISK OF ELECTRICALS OCK
• Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
• Turn off the power when you perform any maintenance.
• Verify that supply voltage is correct by comparing it with the luminaire label information.
• Make all electrical and grounded connections in accordance with the National Electrical
Code and any applicable local code requirements.
• All wiring connections should be capped with UL approved wire connectors.
• Luminaire must be supplied by a wiring system with an equipment grounding conductor.
CAUT ON:
RISK OF INJURY
• Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
• Avoid direct eye exposure to the light source while it is on.
• Account for small parts and destroy packing
material, as these may be hazardous to children.
CAUT ON:
RISK OF FIRE
• Keep combustible and other materials that can
burn away from luminaire and lamp/lens.
• MIN 90°C SUPPLY CONDUCTORS.
Models:
HL-AR80@#-$$%
HL-AR100@#-$$%
HL-AR150@#-$$%
@ = Voltage (U = 100-240/277 Vac, H = 200-480 Vac)
# = Distribution (W = 120° distribution)
$$ = CCT (50 = 5000K)
% = Finish (G = Grey)
Operating characteristic:
Rated Voltage: 100-240/277 Vac or 200-480 Vac, 50/60 z
Ambient Temperate Range: -40°C (-40°F) ~ +60°C (140°F)
© Copyright 2017. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: inf[email protected]
®
Picture is for illustration purposes only.
Your model may vary.
General Safety nformation
This fixture is suitable for use in the following
hazardous (classified) areas as defined by the
National Electrical Code (NEC) and Canadian
Electrical Code (CEC):
azardous Locations
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups F, G
UL Standards Environmental Ratings
UL 844 Suitable for wet location
UL 1598 IP 66 Rating
UL 1598A
Refer to the luminaire nameplate for specific classification
information, maximum ambient temperature suitability and
corresponding operating temperature (T-Code).
Page: 1
REV: 10/05/17

© Copyright 2017. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: inf[email protected]
Fig. 1
nstallation & Operation
Electrical Connection:
1. Loosen the ten M6 hexagon blots with spring washers and nuts of Tank Cover with torque value 7 N-m.
2. The thread of entry hole of Tank is 3/4” NPT. Attach the Tank to suitable conduit.
3. Inset the wire from outside through the conduit and the entry hole of Tank, and then connect to Terminal Block.
4. Introduce the wires of branch circuit as following:
Black-wire connects to Line
White-wire connects to Neutral
Green-wire connects to Ground
5. Re-attach the Tank Cover and tight it by ten M6 hexagon blots with
spring washers and nuts with torque value 7 N-m.
6. Check the tightness of conduit and Tank Cover.
General Wiring Diagram
CAUT ON: Turn off electrical power at fuse
or circuit breaker box before wiring fixture to
the power supply.
Connecting panels to AC source supply:
All units must be individually connected to
the AC supply.
Black = Line
White = Neutral
Green = Ground
Wall/Ceiling/Floor Mounting Bracket:
7. The mounting bracket is for the use of
wall/ceiling/floor mounting.
8. Position the mounting bracket and fix it
by means of two M6 and two M8
hexagon bolts with spring lock washers.
9. Secure the wall/ceiling/floor mounting
bracket to the structure by using
screws (not provided). (Figure 1)
10. The luminaire can be adjusted facing
down 90° from vertical = Lens
horizontal facing down on ceiling
position. (Figure 2).
11. The luminaire can be adjusted up and
down by 45° on wall/floor position only.
(Figure 3).Fig. 3
Ceiling Type:
Wall Type: Floor Type:
Fig. 2
Operating nstructions Hazardous Location Series
MaxLite Hazardous Location Flood Light – Class Division 2
®
Page: 2
REV: 10/05/17

© Copyright 2017. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: inf[email protected]
Servicing
• To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing
maintenance.
• Perform visual, electrical, and mechanical inspections on a regular basis. The environment and frequency
of use should determine this. owever, it is recommended that checks be made at least once a year.
Frequency of use and environment should determine this.
• The external glass should be cleaned periodically to ensure continued luminaire performance. Clean the
glass with a clean, damp, non-abrasive, lint-free cloth. If this is not sufficient, use a mild soap or a liquid
cleaner. Do not use an abrasive, strong alkaline or acid cleaner as damage may occur.
• Inspect the cooling fins on the luminaire to ensure that they are free of any contamination
(i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.
• Mechanically check that all parts are properly assembled.
• Electrically check to make sure that all connections are clean and tight.
Housing
• eavy-duty Anodized Die Casting Aluminum
• Shell surface of electrostatic spraying, Long lasting and Durable
• Shell protection, Over-voltage and Over-heat protection
• Exposed fasteners with quality stainless steel
• Excellent anti-corrosive property
Operating nstructions Hazardous Location Series
MaxLite Hazardous Location Flood Light – Class Division 2
®
Page: 3
REV: 10/05/17

© Copyright 2017. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: inf[email protected]
MaxLite Inc. warrants its products for a minimum period of F VE (5) years from the date of original purchase from
MaxLite or its authorized distributor/dealer (the “Warranty Period”), as follows: If a Product fails to operate during the
Warranty Period as a result of defects in materials or workmanship, MaxLite will, at its option, repair it, replace it with
the same or like Product.
Please refer to Maxlite’s website (at http://maxlite.com/resources/warranties) for the complete
terms and conditions of our warranty.
Limitation of Liability
T E FOREGOING WARRANTY IS EXCLUSIVE, AND IS T E SOLE REMEDY FOR ANY AND ALL CLAIMS,
W ET ER IN CONTRACT, IN TORT OR OT ERWISE ARISING FROM T E FAILURE OF PRODUCT AND IS IN
LIEU OF ALL OT ER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ALL WARRANTIES OF
MERC ANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, W IC WARRANTIES ARE EREBY
EXPRESSLY DISCLAIMED TO T E EXTENT PERMITTED BY LAW AND, IN ANY EVENT, S ALL BE LIMITED TO
T E WARRANTY PERIOD SPECIFIED ABOVE. T E LIABILITY OF MAXLITE S ALL BE LIMITED TO T E TERMS
OF T E EXPRESS WARRANTY SET FORT EREIN. IN NO EVENT WILL MAXLITE BE LIABLE FOR ANY
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING, WIT OUT LIMITATION, DAMAGES
RESULTING FROM LOSS OF USE, PROFITS, BUSINESS OR GOODWILL, LABOR COSTS, REMOVAL OR
INSTALLATION COSTS, DECREASE IN T E LIG T OUTPUT OF T E LAMP, AND/OR DETERIORATION IN T E
LAMP’S PERFORMANCE, W ET ER OR NOT MAXLITE AS BEEN ADVISED OF T E POSSIBILITY T EREOF.
UNDER NO CIRCUMSTANCES S ALL MAXLITE’S ENTIRE LIABILITY FOR A DEFECTIVE PRODUCT EXCEED
T E PURC ASE PRICE OF T AT PRODUCT. WARRANTY SERVICES PROVIDED UNDER T ESE TERMS AND
CONDITIONS DO NOT ENSURE T E UNINTERRUPTED OPERATION OF PRODUCTS; MAXLITE S ALL NOT BE
LIABLE FOR DAMAGES CAUSED BY ANY DELAYS INVOLVING WARRANTY SERVICE.
This Limited Warranty gives you specific legal rights and you may also have other rights that may vary from state to
state. Because some states or jurisdictions do not allow the exclusion or limitation of liability for consequential or
incidental damages, this limitation may not apply to you.
Warranty nformation
Operating nstructions Hazardous Location Series
MaxLite Hazardous Location Flood Light – Class Division 2
®
Page: 4
REV: 10/05/17
This manual suits for next models
9
Other MaxLite Floodlight manuals
Popular Floodlight manuals by other brands

Abtech
Abtech IOM-ALPHA ALP150SH Installation, operation and maintenance instructions

Torch Lighting Systems
Torch Lighting Systems 4009 High Beamer Max user guide

Chauvet
Chauvet Abyss Led user manual

jobmate
jobmate JM18FL Safety and operating manual

luceco
luceco EFLD10B40-06 Installation & operating instructions

Platek
Platek SPRING Assembly instructions