Basic Control Remote
5-year standard warranty (further details available at www.maxlite.com/warranties) Product may be eligible for a warranty extension to
10 years, for an additional fee. Contact MaxLite for details.
Phone: 1-800-555-5629 Fax: 973-244-7333 Web: www.maxlite.com E-mail: info@maxlite.com Rev: 04/06/21
© 2021 Specications subject to change without notice.
PROJECT NAME:___________________________________________________________________ CAT. #: _________________________________________________________
NOTES:____________________________________________________________________________ FIXTURE SCHEDULE:_____________________________________________
Features
• Easy eld commissioning with c-Max basic control nodes and controls ready xtures
• Versatile with many packed features
• Ability to set High Trim
• Bi-Level dimming with dim-to-off capability
• Daylight harvesting as ON/OFF or CAM (continuous adjustment mode)
• Manual override dimming mode to adjust desired dimming level
• Point and click and visual cues for easy commissioning
• 4 memory modes to easily store sensor settings
• Check www.maxlite.com/cmax/ for c-Max xture compatibility
• 5 Year Warranty
Ordering Information
MODEL
NUMBER ORDER CODE
CN-REMOTE 105567
Remote Controller Specications
POWER SUPPLY 2x CR2032 (Included)
COMMUNICATION IR
COMMUNICATION
RANGE
CN-RTPSW up to 20ft*/6m
CN-RTMST / CN-RDMSW
/ CN-RDMSB up to 35ft/10m
OPERATING TEMPERATURE 32°F TO 104°F / 0°C to 40°C
DIMENSIONS 5.70" X 2.36" X 0.47" /
145mm X 60mm X 12mm
PRELIMINARY
*IR commissioning range may be impacted due to the lighting environment
Page 2of 3
Basic Control Remote
Phone: 1-800-555-5629 Fax: 973-244-7333 Web: www.maxlite.com E-mail: info@maxlite.com Rev: 04/06/21
© 2021 Specications subject to change without notice.
SMALL TAB
BIGGER TAB
Product Dimensions
FRONT SIDE
Battery Replacement Instructions
Step 1: Flip the remote over. Push the small tab on the left towards
the center of the remote, and pull the bigger tab in the
center away from the remote at the same time.
Step 2: By following step 1, the battery tray will come loose.
Step 1: Flip the remote over. The small tab on the battery tray
should be on the left as shown in the image.
Step 2: Insert two (2) CR2032 batteries into the tray. The positive
side of the batteries should be face up.
Step 3: Once batteries are in place, insert the tray into the remote.
Opening Battery Tray: Installing Batteries:
Common User Errors:
1: If the small tab on the battery tray is not shown as above
(see picture of battery installation), it will not t into the remote.
2: If the negative side of the batteries is facing up, the remote will not be powered.
3: Do not pull the center tab only when opening the battery tray. The small tab has
to be engaged as listed in the above instructions to remove the tray correctly.
2.36”
5.70”
0.46”
Page 3of 3
Basic Control Remote - Quick Guide
Phone: 1-800-555-5629 Fax: 973-244-7333 Web: www.maxlite.com E-mail: info@maxlite.com Rev: 04/06/21
© 2021 Specications subject to change without notice.
HOLD TIME 2 Seconds
STANDBY DIM 50%
STANDBY TIME 2 Seconds
Default settings can be changed during commissioning
For Standby Dim, “0%” means on/o control. There is no standby dimming level.
For Standby time “∞” means bi-level dimming control. Luminaire will never turn o.
Memory Mode (Commissioning)
To begin commissioning, follow the steps below:
1. Select either M1, M2, M3, or M4.
2. Indicator lights on the remote will illuminate to indicate the
current saved settings.
3. Settings can be changed by pressing appropriate buttons
in the highlighted gray area of the remote. (HIGH, SENSITIVITY,
HOLD TIME, STANDBY DIM, STANDBY TIME, and PHOTOCELL).
Review selected settings and make changes as necessary.
4. Point remote to desired luminaire to commission and press “SEND”.
5. If conguration is successful, luminaire will ash suggesting settings
are saved.
Note that any changes made to the sensor settings are automatically
saved to the memory banks M1, M2, M3 or M4 and will override previous
settings.
If commissioning multiple luminaires, select the congured memory
mode M1/M2/M3/M4 then follow steps 4 and 5.
Test Mode
Press “TEST” to enter test mode. Luminaire will ash two times.
Test mode will last ve (5) minutes then return to previous setting.
To Turn Lights ON
Press “ON” to turn luminaire on.
To Turn Lights OFF
Press “OFF” to turn luminaire off.
Manual Dimming Mode
Press “ON”, luminaire will blink, then press DIM+ or DIM- to adjust
dimming level.
Continuous Adjustment Mode or CAM
(Daylight Harvesting)
Continuously adjusts dim levels in response to changes in ambient light.
1. Point IR remote to desired luminaire
2. Enter Manual Dimming Mode - Press “ON”, luminaire will blink,
then press DIM+ or DIM- to adjust the desired light level.
3. Press “CAM”, indicator lights on the remote will indicate current
saved settings. Note: only HIGH, SENSITIVITY, and HOLD TIME
can be selected for CAM settings. (Sensitivity should be set to
either LOW or HIGH) CAM feature recommended with CN-RTPSW
sensor only.
4. Review selected settings and make changes as necessary.
Press “SEND”.
5. If conguration is successful, luminaire will blink to conrm
setting saved.
If congurating multiple luminaires, repeat steps
1-5 above to congure CAM settings. Light levels
has to be congured for each luminaire individually.
Reset Mode
Press “RESET” to enter reset mode. Luminaire will blink to indicate
reset is complete. Sensor will default to original settings shown in the
above table.
Remote Settings
FEATURE DEFINITION SETTINGS
HIGH MODE Set High Trim or Maximum light output setting SET MAXIMUM THRESHOLD VALUE 50/75/100%.
(SENSOR DEFAULT = 100%)
SENSITIVITY Set motion detection sensitivity OFF (NO OCCUPANCY) / LOW (50%) / HIGH (100%)
(SENSOR DEFAULT=HIGH)
HOLD TIME Time luminaire stays at the High Trim threshold when no
motion detected before going into Standby Dim level.
30S/5M/15M/30M
(SENSOR DEFAULT=5MIN)
STANDBY DIM With no motion detected and hold time elapsed,
light output is reduced to this level 0/10/30/50% (SENSOR DEFAULT=50%)
STANDBY TIME With no motion detected, length of time luminaire stays
at the Standby Dim level before turning OFF.
10S / 5MIN / 15MIN / 30MIN / 60MIN / ∞
(SENSOR DEFAULT=30MIN)
PHOTOCELL Turns luminaire ON/OFF based on photosensor settings.
(Outdoor application)
LOW(1FC) / MEDIUM(20FC) / HIGH(50FC)
(SENSOR DEFAULT = PC OFF)
PRELIMINARY
Check out the
remote commissioning
video here.

This manual suits for next models

1

Popular Remote Control manuals by other brands

iStabilizer SRIOS-01 user manual

iStabilizer

iStabilizer SRIOS-01 user manual

Apollo TXMULTI manual

Apollo

Apollo TXMULTI manual

Firstech 2WSHLCD -5P user guide

Firstech

Firstech 2WSHLCD -5P user guide

Mitsubishi Electric PZ-61DR-E Simple operation manual

Mitsubishi Electric

Mitsubishi Electric PZ-61DR-E Simple operation manual

Top WA100 user guide

Top

Top WA100 user guide

Tele Radio 860 Lion manual

Tele Radio

Tele Radio 860 Lion manual

De Haardt Xtra.Mini Remote Control user manual

De Haardt

De Haardt Xtra.Mini Remote Control user manual

Ilockey IC 906 Operating	 instruction

Ilockey

Ilockey IC 906 Operating instruction

REMdevice BRICK Installation and operating manual

REMdevice

REMdevice BRICK Installation and operating manual

Remote Solution TSR750 user manual

Remote Solution

Remote Solution TSR750 user manual

Philips SRU152/10 Instructions for use

Philips

Philips SRU152/10 Instructions for use

VADDIO TouchVIEW Installation & user guide

VADDIO

VADDIO TouchVIEW Installation & user guide

fakro ZWP15 user manual

fakro

fakro ZWP15 user manual

Hisense J1-91 instructions

Hisense

Hisense J1-91 instructions

Toparc RC-HA2 manual

Toparc

Toparc RC-HA2 manual

Norvado Potenza Remote guide

Norvado

Norvado Potenza Remote guide

RCA RCTC4GB Read me first

RCA

RCA RCTC4GB Read me first

Viessmann Vitocom 100 operating instructions

Viessmann

Viessmann Vitocom 100 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.