manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MB
  6. •
  7. Scale
  8. •
  9. MB Tanner RaceScale 50220 User manual

MB Tanner RaceScale 50220 User manual

10" WIRELESS
RaceScale
#50220
Instructions
FOR FURTHER TECHNICAL ASSISTANCE CONTACT:
TANNER RACING PRODUCTS by MB
10 COOPERATIVE WAY
WRIGHT CITY, MO. 63390
800-467-2464 / 636-745-7757
TannerRacing.com
Frequency Change Instructions
If there is interference with the operation of the scales (ex. much slower operation
than normal or no operation at all) it may be necessarry to change the frequency.
This can be done by following these steps.
1. Set all scale pads out individually (at least 12" apart).
2. Pivot the hand held antenna until the antenna is perpindicular to the floor (this
is essential for communication between the pads and hand held) and turn the hand
held on by pushing the "ON/OFF" button. DO NOT turn the scale pads on at this
time.
3. When the menu appears, select "RF Frequency" by pressing the "OK" button.
Give the unit a few seconds to scan the channels and you will see numbers appear
under "ACTIVITY". Scroll the arrow down and select the frequency with the low-
est number (least amount of interference) by pressing "OK". (Typically 903-915
commumicate the fastest.)
4. Turn the hand held off by pushing the "ON/OFF" button for 2 seconds.
5. Turn the scale pads on by switching the battery switch on each scale pad to
"ON" and press the reset button on the front of the black box.(Green light will start
blinking indicating power is on.)
6. Turn the hand held back on by pushing the "ON/OFF" button.
7. When the menu appears, select "Weigh Vehicle" by pressing the "OK" button.
Give the hand held 2 minutes to start communication with the scale pads. When the
red lights on ALL scale pads are blinking and numbers appear on the scaling screen
the frequency has been changed and the scales are ready to use. If you find that one
scale does not blink red after 2 minutes, simply turn that scale off and back on and
press the reset button.
Hand Held
Battery Charger
Communications
Cable
Hand Held
Scale Display
Please read all instructions prior to operating scales.
1. Set all scale pads out individually (at least 12" apart).
2. Turn on the scale pads by switching the power switch on each
scale pad to "ON" and press the reset button on the front of the
black box.(Green light will start blinking indicating power is on.)
3. Pivot the hand held antenna until the antenna is perpindicular to the floor
(this is essential for communication between the pads and hand held) and turn
the hand held on by pushing the "ON/OFF" button.
4. When the menu appears, select "Weigh Vehicle" by pressing the "OK" but-
ton. Give the hand held a few seconds to start communication with the scale
pads. When the red lights on ALL scale pads are blinking and numbers appear
on the scaling screen the scales are ready to use. If you find that one scale does
not blink red after 1 minute, simply turn that scale off and back on and press
the reset button.
5. Zero the system (if necessary) by pushing the "MENU" button and selecting
zero all pads. This will then display zero's in the locations selected. (this may
take a few seconds)
6. Put your racecar on the scales and the weights will register, the %'s and
totals will show on the display.
7. Turn the hand held off by pushing the "ON/OFF" button for 2 seconds.
8. Turn the scale pads off to conserve battery life.
9. The hand held unit contains rechargeable batterys, simply re-
charge by plugging the power adapter into the unit. For best performance,
charge battery for 12 hours. Each scale pad contains (4) AA batteries.
Button Operation
Scaling Instructions
TURNS UNIT ON OR OFF
SELECTS DESIRED FUNCTION
System ID / Pad Location Change
If you wish to change a pad location (ex. change the RF to the LR etc.) or change
the system ID, this can be done by following these steps.
1. Set all scale pads out individually (at least 12" apart).
2. Turn on the scale pads by switching the power switch on each scale pad to
"ON" and press the reset button on the front of the black box.(Green light will
start blinking indicating power is on.)
3. Pivot the hand held antenna until the antenna is perpindicular to the floor (this
is essential for communication between the pads and hand held) and turn the hand
held on by pushing the "ON/OFF" button.
4. When the menu is displayed on the hand held, select "SYSTEM ID". Scroll
the arrow down to the word ID and press the right arrow over to where the name
is. When a character is underlined, you can change it to whatever you wish using
the up and down arrows, this will make your system unique so no one else with
a wireless scale system can pick up on your "channel" and see your information.
Once you are finished scroll back completely to the left and back up until the ar-
row is pointiong to "Save and Exit" then press "OK".
5. Plug the communications cable into the hand held and into one scale pad.
6. Press "MENU" and scroll down past "UNITS" & "PAD SETUP"
will appear. This will allow you to change pad location and/or download a new
system ID. Scroll the arrow down until it is pointed at the pad you are plugged
into (RF,LF,RR or LR) and press "OK". You will see a message scroll across the
bottom of the screen and the message "Pad set OK" will flash. Plug the cable into
every scale pad to complete this step, each time selecting the pad you are plugged
into. Once you have completed all 4 scale pads, you must turn the pads off by flip-
ping the switch to "OFF"and turn the hand held off by pressing the "ON/OFF"
button for 2 seconds.
7. Complete steps 1-5 of the scaling instructions and your scales are now ready to
be used.
8. Turn the scale pads and hand held off to conserve battery life.
DISPLAYS THE MENU
TURNS BACKLIGHT ON SCROLLING ARROWS
Thank you for your business.
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.

This manual suits for next models

1

Other MB Scale manuals

MB Tanner RaceScale User manual

MB

MB Tanner RaceScale User manual

MB Tanner Racing Products Deluxe RaceScale User manual

MB

MB Tanner Racing Products Deluxe RaceScale User manual

MB Tanner RaceScale 50320 User manual

MB

MB Tanner RaceScale 50320 User manual

Popular Scale manuals by other brands

PCE Health and Fitness PCE-CS 3000N manual

PCE Health and Fitness

PCE Health and Fitness PCE-CS 3000N manual

Taylor 7519 instruction manual

Taylor

Taylor 7519 instruction manual

Nokia Body Quick installation guide

Nokia

Nokia Body Quick installation guide

RSF Elektronik MS 25 MP Mounting instructions

RSF Elektronik

RSF Elektronik MS 25 MP Mounting instructions

Tanita KP-601 instruction manual

Tanita

Tanita KP-601 instruction manual

ADE PWN5 operating manual

ADE

ADE PWN5 operating manual

Steinberg Systems SBS-PF-100A1 user manual

Steinberg Systems

Steinberg Systems SBS-PF-100A1 user manual

Truweigh Force user guide

Truweigh

Truweigh Force user guide

JB INDUSTRIES DS-20000S operating manual

JB INDUSTRIES

JB INDUSTRIES DS-20000S operating manual

Pinnacle Technology PS1XA Technical manual

Pinnacle Technology

Pinnacle Technology PS1XA Technical manual

Measuretek EHL-3 Operation manual

Measuretek

Measuretek EHL-3 Operation manual

EDLUND EDL-10 operating instructions

EDLUND

EDLUND EDL-10 operating instructions

eatsmart ESBS-61 quick guide

eatsmart

eatsmart ESBS-61 quick guide

Concept2 VK5510 manual

Concept2

Concept2 VK5510 manual

My Weigh GEMPRO-150 instruction manual

My Weigh

My Weigh GEMPRO-150 instruction manual

Easy@Home 93444 user guide

Easy@Home

Easy@Home 93444 user guide

Silvercrest SPWS 180 A1 operating instructions

Silvercrest

Silvercrest SPWS 180 A1 operating instructions

Easy@Home CF350BT user manual

Easy@Home

Easy@Home CF350BT user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.