INCLUDING the device into Z-Wave network:
1. Set controller into INCLUSION mode. Follow instructions provided by controller manufacturer.
2. Press and hold any key on the panel for 8 seconds.
Note: If inclusion is successful, all INDICATION LEDs on the panel will turn green, and all switches
will turn on.
EXCLUDING the device from Z-Wave network:
1. Set controller into EXCLUSION mode. Follow instructions provided by controller manufacturer.
2. Press and hold any key on the panel for 8 seconds.
Note: If the exclusion is successful, all INDICATION LEDs on the panel will turn orange, and all
switches will turn off. The exclusion will delete all association data.
Turning on/off the device:
The device can be controlled by:
Pressing any key.
Sending commands through controller or gateway.(the command classes which support this
function are Basic Command Class, Binary Command Class, Switch All Command Class, and
Multi Channel Command Class.)
Multi Channel Control:
The switch can be controlled by command “MULTI_CHANNEL_ENCAP” in the command class
“COMMAND_ CLASS_MULTI_CHANNEL”.
COMMAND_CLASS_MULTI_CHANNEL
COMMAND_CLASS_SWITCH_BASIC or COMMAND_CLASS_SWITCH_BINARY
BASIC_SET/BASIC_GET or BINARY_SET/BINARY_GET
Value ( 0xFF -- ON 0x0 -- OFF )
Multi ChannelAssociation:
To set association groups by the command “COMMAND_CLASS_MULTI_CHANNEL_
ASSOCIATION”.
The device supports 3 association groups (AG). The 1st AG is used for reporting devices’state to
the controller if any changes happen. This group supports one Node, which suggested to be controller
Node. The rest 2 AGs is used for switching associated devices,and it can support up to 5 nodes or
terminals.
For the 1st AG, a report will be sent to associated controller when any state changes happen in
other group(s). For the rest 2 AGs, the touch panel switch will send Basic Set Command to related
association groups when setting switch state by gateway or key-pressing. Then the switch states of
associated devices and their related key will be synchronic (S1-AG2, S2-AG3).