Revision B/a, February 2022
Générateur de brouillard Fog generators
10301 av. Pelletier, Montreal, Quebec, H1H 3R2, Canada
T (514) 272-6040 1-800-663-3020 F (514) 722-3229
Working with DMX/RDM Control (DMX Mode)
•Connect a DMX line to DMX In connector (Male XLR-5 connector).
•Select the communication mode in the «INTERFACE COMM. ». When the «AUTO» mode is activated, the MDG theONE is then
controlled by DMX, if there is a signal.
•Set the DMX Start Address in the Interface Menu («INTERFACECOMM.DMX ADDR») and choose any value between 1 and 508
(508+5 = 512, last DMX channel).
The DMX Start Address can be reassigned via a RDM control.
The Interface uses five (5) DMX channels:
Channel 1 0 (0%) <UNIT OFF ≤128 (50%) <UNIT ON ≤255 (100%)
Channel 2 0 (0%) <MODE HAZE ≤128 (50%) <MODE FOG ≤255 (100%)
Channel 3 0 (0%) – 255 (100%), FOG OUTPUT (from minimum to maximum pressure)
Channel 4 0 (0%) <FOG OFF ≤128 (50%) <FOG ON ≤255 (100%)
Channel 5 0 (0%) – 255 (100%), EXTERNAL FAN (from minimum to maximum speed)
Working with Network Control (Network Mode)
The network interface, developed by Pathway Connectivity Solutions, supports all major Ethernet protocols. If you don’t have a control
program, install Pathscape (4.3.2 or above) by downloading the latest build from https://pathway.acuitybrands.com/.
•Reset the IP address on your computer to 10.0.0.1 with a subnet mask of 255.0.0.0. If the computer uses a wireless card, disable it and
turn the transmitter off.
•Connect to the MDG theONE via an Ethernet switch, using a standard Ethernet cable.
•Switch the control mode to Ethernet («INTERFACECOMM.ETHERNET»).
•Start Pathscape.
To modify the properties of the Pathway interface, you need to log In the Security Domain. The MDG theONE is sent with a Recovery Key to
be able to reset the password of the Domain (See Pathscape Manual for more details).
•By default, the interface is configured for Dynamic IP, and for all the major protocols: Pathway ssACN (Secure sACN), E1.31 streaming
ACN (sACN), Art-Net, Pathport Protocol, ShowNet.
•The field Generator Status is a summary of the
status of the fog generator, including the fail status.
•The Universe Number, as well as the DMX Start
Address can be assigned either on the fog generator
or in the properties tab.
Press Send button when you want to update the
MDG theONE.
NOTE: DMX output, configured as whole universe, can
act as a E1.20 RDM controller, when used with
Pathscape.
… For further details, please read the User Guide.