Me GSV-4 User manual

4 channel measuring amplifier GSV-4
GSV-4BT
GSV-4USB
Operating instructions
Updated: 02.02.20 8
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de


Contents
Inhaltsverzeichnis
Straingage measuring amplifier GSV-4USB.......................................................................................4
Description..........................................................................................................................................4
Dimensions.........................................................................................................................................5
Technical data....................................................................................................................................6
Connection assignment....................................................................................................................7
Strain Gage measuring amplifier GSV-4BT...................................................................................... 8
Description........................................................................................................................................ 8
Dimensions....................................................................................................................................... 9
Technical data..................................................................................................................................20
Wiring diagram.................................................................................................................................2
Technical data GSV-4BT M 2.......................................................................................................25
Switch configuration GSV-4BT M 2............................................................................................26
Measurement resolution................................................................................................................28
Order variants GSV-4BT.................................................................................................................29
Programming / configuration............................................................................................................30
Scaling of measured values..........................................................................................................30
Measuring range 2.0 mV/V............................................................................................................30
Measuring range 0.0 mV/V.........................................................................................................30
Measuring range 0.0 to 5 V............................................................................................................3
Measuring range 0.0 to 0 V.........................................................................................................3
Measuring range PT 000...............................................................................................................3
Measuring range K thermocouple cable.....................................................................................32
Commands for configuration........................................................................................................32
List of commands...........................................................................................................................32
Description of commands.............................................................................................................34
Protocol for measured values.......................................................................................................37
Protocol for commands.................................................................................................................37
Protocol for responding to commands.......................................................................................37
Digital IOs..........................................................................................................................................39
Analogue input.................................................................................................................................43
CAN bus.................................................................................................................................................44
Protocol for measured values.......................................................................................................44
Protocol for commands.................................................................................................................44
Protocol for responding to commands.......................................................................................44
Configuring the CAN-ID..................................................................................................................45
Data frequency and filter................................................................................................................46
Analogue filter..................................................................................................................................46
Digital filter........................................................................................................................................46
Annex......................................................................................................................................................48
Connection figures for GSV-4BT SD and GSV-4BT LD.............................................................48
Changelog.........................................................................................................................................52
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 3

Straingage measuring amplifier GSV-4USB
GSV-4USB M 2
Front view sensor connection
GSV-4USB SUB-D37
Front view sensor connection
Description
This 4-channel measuring amplifier for sensors with strain gauges is equipped with a USB
interface. The voltage is supplied via the USB port at the back of the measuring amplifier.
The measuring amplifier can be delivered with an SUB-D37 connection or with 4x M 2 ports.
The measuring amplifier has eight digital inputs and outputs.
On the backside SubD25 socket, strain gauge full-bridges and half-bridges 20 Ohm up to
kOhm as well as PT 000 temperature sensors and 000 Ohm single grid strain gages or
voltages 0 ... 5V can be connected.
The front-end M 2 socket is configured by default for strain gauge full-bridge connections
and for voltage inputs 0 ... 5V and 0 ... 0V.
ME-Meßsysteme GmbH
4 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de
•4-channels
•Power supply via USB port
•Inputs for Straingage / 0– 0 V / PT 000
•Measurement ranges 2 mV/V / 0 mV/V
•Straingage quarter / half / full bridges
•8 digital inputs / outputs
•Data rate 0 Hz–500 Hz

Dimensions
Figure 2: Dimensions GSV-4USB M12
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 5
Figure 1: Dimensions GSV-4USB SUB-D37

Technical data
Accuracy class 0.05 %
Inputs
Resolution 6 Bit
Straingage inputs
Full bridge
Half bridge
Quarter bridge
89-5000
89-5000
20 / 350 / 000
Ohm
Ohm
Ohm
Common mode rejection
at 60 Hz common-mode signal 95– 0 dB
Measurement frequencies
Data frequency 0 – 500 Hz
Sampling frequency .92 MHz
Cut-off frequency
analogue
digital
450
Notch filter
Hz
Hz
Outputs
Bridge supply voltage
Current load capacity
2.5
30
Volt
mA
Fixed voltage output
Current load capacity
5
20
V
mA
Switching outputs/inputs
I/O -8
Current load capacity:
TTL level
5 (active High)
5
V
mA
Interface USB . , USB 2.0 compatible
Supply voltage
Nominal range
Isolation voltage
Current consumption
4.5...5.5 via USB port
000
< 200
V DC
Vrms
mA
Temperature range
Nominal temperature range
Storage temperature range
Zero point drift
Sensitivity drift
- 0…+65
-40…+85
< 0.05
< 0.0
°C
°C
%/ 0°C
%/ 0°C
Dimensions
L x W x H 06 x 9 ( 32) x 32 mm x mm x mm
Protection type / Weight
Protection type IP40
Weight GSV-4USB SUB-D37 239 g
Table : Technical data GSV-4USB
ME-Meßsysteme GmbH
6 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de

Connection assignment
Connection plan for 37-pin D-sub port
GSV-4USB assignment 37-pin D-sub port (PIN No.)
Channel Channel 2 Channel 3 Channel 4
+USpositive sensor supply 20 2 29
+UDpositive differential input 22 4 3 3
QB 000 quarter bridge extension kOhm 23 5 4 32
HB half bridge extension 24 6 5 33
-UDnegative differential input 25 7 6 34
-USnegative sensor supply 27 9 8 36
UEanalogue input 28 0 9 37
screen
Table 2: Analogue inputs
Connection assignment for GSV-4USB 12
5-pin port M 2x , type 763
Top view:
5-pin Description Colour code for cables
2 -US negative bridge supply white
+US positive bridge supply brown
3 +UD positive differential input blue
4 -UD negative differential input black
5 AUXin input without cable grey
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 7
1
19
37 20
12
4 3
5

Connection of full bridge with SUB-D37 version
The following graphics show the connection of a full bridge to channel through to channel
4.
ME-Meßsysteme GmbH
8 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de

Connection of half bridge with SUB-D37 version
The following graphics show the connection of a half bridge to channel through to channel
4.
The bridge extension should be adapted depending on the application.
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 9

Connection of quarter bridge with SUB-D37 version
The following graphics show the connection of a quarter bridge to channel through to
channel 4.
The bridge extension should be adapted depending on the application.
ME-Meßsysteme GmbH
0 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de

Connection of full bridge with 12 version
The following graphic shows the connection of a full bridge for the M 2 version.
Connection of half bridge with 12 version
The following graphic shows the connection of a half bridge for the M 2 version.
The bridge extension should be adapted depending on the application.
Please set the solder bridges:
•HB when using channel
with a half bridge.
•HB2 when using channel 2
with a half bridge.
•HB3 when using channel 3
with a half bridge.
•HB4 when using channel 4
with a half bridge.
Solder bridges: Figure 3: Solder bridges for
configuring bridge extensions
see page
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de

Connection of quarter bridge or PT1000 with 12 version
The following graphic shows the connection of a quarter bridge for the M 2 version.
The bridge extension should be adapted depending on the application.
Please set the solder bridges:
•HB when using channel
with a quarter bridge.
•HB2 when using channel 2
with a quarter bridge.
•HB3 when using channel 3
with a quarter bridge.
•HB4 when using channel 4
with a quarter bridge.
Solder bridges: Figure 3: Solder bridges for
configuring bridge extensions
see page
Adapting the bridge extension with 12 version
The bridge extension can be adapted individually for each channel; open the device and
extend the desired solder bridge according to the following figure.
ME-Meßsysteme GmbH
2 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de
Figure 3: Solder bridges for configuring bridge ex ensions

Adapting the bridge extension with Sub-D37 version
The bridge extension can be adapted individually for each channel; open the device and
extend the desired solder bridge according to the following figure.
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 3
F
Figure 4: Solder bridges for configuring bridge ex ensions

Altering Straingage input to the voltage input
Opening the device
.Remove both screw covers from the input side and remove the fastening screws from the
front cover.
2.The two hexagonal bolts on the 37-pin D-Sub port must be loosened using a socket
spanner (5 mm).
3.The printed circuit board is pulled out on the side of the 25-pin D-Sub port.
ME-Meßsysteme GmbH
4 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de

Wiring diagram for position sensors
The measuring amplifier GSV-4USB must be configured by the manufacturer separately
when using it with potentiometric position sensors (linear potentiometers or draw wire
displacement sensors) for the M 2 version.
The position sensor’s wiper is connected to the measuring amplifier’s “Aux” input (M 2) or
“UE“ (SubD37). The position sensor supplies via the sensor supply +Us and -Us.
5-pin port 37-pin D-SUB port
The potentiometric position sensor is supplied with 2.5 V.
The “Aux” input or UE records voltages of 0...5 V.
Connection assignment
Label 5-pin port 37-pin D-SUB port
CH CH 2 CH 3 CH 4
positive supply +Us positive supply +Us 20 2 29
negative supply -Us 2 negative supply -Us 27 9 8 36
“Aux” input 5 UE input 28 0 9 37
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 5

Connection of the Way Con – draw wire sensor SX
4-pin port
Waycon draw wire sensor
SX
5-pin port Label Colour code
M 2 sensor-actuator
cable
(+supply) positive supply +Us brown
3 (GND) 2 negative supply -Us blue
2 (wiper) 5 “Aux” input white
4-pin port
Waycon draw wire sensor
SX
37-pin D-SUB port
CH CH 2 CH 3 CH 4
(+supply) 20 2 29 pos. supply +Us
3 (GND) 27 9 8 36 neg. upply -Us
2 (wiper) 28 0 9 37 UE input
ME-Meßsysteme GmbH
6 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de

Connection assignment SUB-D25 port
GSV-4USB assignment 25-pin D-sub port (PIN-No.)
IO 5 V fixed voltage output
IO GND 2
IO 3
IO 2 4
IO 3 5
IO 4 6
IO 5 7
IO 6 8
IO 7 9
IO 8 0
TX
RX 2
GND 3
Channel Channel 2 Channel 3 Channel 4
GND 4 7 20 23
0...5V Input 5 8 2 24
AUX Input 6 9 22 25
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 7

Strain Gage measuring amplifier GSV-4BT
Figer 5: GSv-4BT M12
Description
The measuring amplifier GSV-4BT is suited to wireless measurement data acquisition with
wire strain gauge sensors. The GSV-4BT is suitable for connecting Straingage full bridges
and half bridges. For quarter bridges ( 20 Ohm, 350 Ohm, and 000 Ohm), there is a
connection option in three-wire technology.
Data is transmitted by radio via the Bluetooth Standard 2.0+EDR with serial port profile
(SPP). The range is 20 m in buildings or up to 00 m when in direct line of sight. Commercial
Bluetooth dongles with Widcom or Toshiba drivers which support the “serial-port-protocol”
are suitable as receivers.
Data rates are possible from 0 Hz to 500 Hz. They are supplied via e.g. a lithium-polymer
battery. By opening the interface for the application software, the module is switched on.
Current consumption is less than 50 mA. When not in use, current consumption is under
0 mA.
A battery can be charged at 5V supply voltage via an integrated charge regulator. Threshold
values or digital outputs can be programmed with the 8 digital outputs
.
Standard PIN: 0000
ME-Meßsysteme GmbH
8 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de
•Bluetooth interface
•4-channels
•Inputs for Straingage / 0– 0 V / PT 000
•Measurement ranges 2 mV/V / 0 mV/V
•Straingage quarter / half / full bridges
•8 digital inputs / outputs
•Data rate 0 Hz–500 Hz

Dimensions
GSV-4BT SD
GSV-4BT LD
ME-Meßsysteme GmbH
676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de 9

Technical data
Accuracy class 0.05 %
Inputs
Resolution 6 Bit
Straingage inputs
Full bridge
Half bridge
Quarter bridge
89-5000
89-5000
20, 350, 000
Ohm
Ohm
Ohm
Common mode rejection
at 60 Hz common-mode signal 95– 0 dB
Measurement frequencies
Data frequency 0–500 Hz
Sampling frequency .92 MHz
Cut-off frequency
analogue
digital
450
Notch filter, configurable
Hz
Outputs
Bridge supply voltage
Current load capacity
2.5
30
Volt
mA
Switching outputs/inputs I/O -8
Level
Current load capacity:
TTL level
5 (active High)
5
V
mA
Interface Bluetooth Standard 2.0+EDR
Supply voltage
Nominal range
Current consumption @ 4.2 V DC
Charge regulator
Current consumption @ 5.2 V DC
3.3...4.2
< 50
5.0 ± 0.5
< 450
V DC
mA
V DC
mA
Temperature range
Nominal temperature range
Storage temperature range
Zero point drift
Sensitivity drift
- 0…+65
-40…+85
< 0.05
< 0.0
- 0…+65
-40…+85
%/ 0°C
%/ 0°C
Dimensions
L x W x H 60 x 33 x 0 mm x mm x mm
Protection type
IP64
Table 3: Technical data GSV-4BT
ME-Meßsysteme GmbH
20 676 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de
Other manuals for GSV-4
1
This manual suits for next models
4
Table of contents
Other Me Amplifier manuals