Installation Manual
Type
:
DDRH Ultra Wide Input DIN Rail Type DC-DC Converter
DDRH-15-5P/ST/DR INPUT: 150~1500VDC OUTPUT: 5V 2A
DDRH-15-12P/ST/DR INPUT: 150~1500VDC OUTPUT: 12V 1.25A
DDRH-15-15P/ST/DR INPUT: 150~1500VDC OUTPUT: 15V 1A
DDRH-15-24P/ST/DR INPUT: 150~1500VDC OUTPUT: 24V 0.625A
DDRH-30-12P/ST/DR INPUT: 150~1500VDC OUTPUT: 12V 2.5A
DDRH-30-15P/ST/DR INPUT: 150~1500VDC OUTPUT: 15V 2A
DDRH-30-24P/ST/DR INPUT: 150~1500VDC OUTPUT: 24V 1.25A
DDRH-30-48P/ST/DR INPUT: 150~1500VDC OUTPUT: 48V 0.625A
DDRH-45-12P/ST/DR INPUT: 150~1500VDC OUTPUT: 12V 3.75A
DDRH-45-15P/ST/DR INPUT: 150~1500VDC OUTPUT: 15V 3A
DDRH-45-24P/ST/DR INPUT: 150~1500VDC OUTPUT: 24V 1.87A
DDRH-45-48P/ST/DR INPUT: 150~1500VDC OUTPUT: 48V 0.938A
DDRH-60-5 INPUT: 150~1500VDC OUTPUT: 5V 10A
DDRH-60-12 INPUT: 150~1500VDC OUTPUT: 12V 5A
DDRH-60-24 INPUT: 150~1500VDC OUTPUT: 24V 2.5A
DDRH-60-48 INPUT: 150~1500VDC OUTPUT: 48V 1.25A
DDRH-120-12 INPUT: 250~1500VDC OUTPUT: 12V 8.4A
DDRH-120-24 INPUT: 250~1500VDC OUTPUT: 24V 5A
DDRH-120-32 INPUT: 250~1500VDC OUTPUT: 32V 3.75A
DDRH-120-48 INPUT: 250~1500VDC OUTPUT: 48V 2.5A
DDRH-240-12 INPUT: 250~1500VDC OUTPUT: 12V 16.7A
DDRH-240-24 INPUT: 250~1500VDC OUTPUT: 24V 10A
DDRH-240-32 INPUT: 250~1500VDC OUTPUT: 32V 7.5A
DDRH-240-48 INPUT: 250~1500VDC OUTPUT: 48V 5A
NOTE:
DDRH-15/30/45-xxP:PCB mounting type
DDRH-15/30/45-xxST:Screw terminal type
Introduction
DDRH series is a DIN Rail type DC-DC converter with main features including DIN rail-type easy installation , ultra
wide input voltage, wide range operating temperature, DC OK relay contact and full protective functions...etc.
DDRH-15/30/45/60 series has ultra-high input voltage: 150~1500Vdc and various output options: 5V / 12V /24V /
48V. DDRH-120/240 series has ultra-high input voltage: 250~1500Vdc and various output options: 12V / 24V /32V /
48V.DDRH series is suitable for industrial automation, surveillance, telecommunication and can be widely deployed
in the applications of new energy generation such as solar power, and windmill power generation, for instances,
photovoltaic power systems, high voltage inverting and so forth.
Installation
(1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
(2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on
the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not
allowed.
Installation Manual
(3)Use copper wire only, and recommended wires are shown as below.
AWG
20
18
16
14
Rated Current of Equipment
(Amp)
5A 7A 10A 15A
Cross-section of Lead(mm2)
0.5
0.8
1.3
2.1
Note
:
Current each wire carries should be de-rated to 80% of the current suggested above when
using 4-6 wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
(4)Use wires that can withstand temperatures of at least 90°C, such as UL1015.
(5)Recommended wire strapping length is 6mm (0.236”).
(6)Recommended screwdriver is 3mm, slotted type.
(7)The recommended torque setting for terminals is shown as below.
Terminal Screw
Series INPUT
OUTPUT
DDRH-15
5 kgf-cm (4.4Lb-in)
5 kgf-cm (4.4Lb-in)
DDRH-30
5 kgf-cm (4.4Lb-in)
5 kgf-cm (4.4Lb-in)
DDRH-45
5 kgf-cm (4.4Lb-in)
5 kgf-cm (4.4Lb-in)
DDRH-60
6 kgf-cm (5.2Lb-in)
5.1kgf-cm (4.42 Lb-in)
DDRH-120
5.1kgf-cm (4.42 Lb-in)
5.1kgf-cm (4.42 Lb-in)
DDRH-240
8.15kgf-cm (7 Lb-in)
5.1kgf-cm (4.42 Lb-in)
(8)External fuse wiring instruction :
External fuse is required. Fuse specification: 4A/1500Vdc.
The suggested fuse and fuse holder model:
Fuse brand
Manufacturer Part NO.
MW’s Order NO.
Fuse
Fuse Holder
Fuse + Fuse Holder
Walter
WJ30-4
WJ30-H
DDRH-WJ30-4-H
Littelfuse
SPXV-4A
LFPXV/LPXV
Not provide
Bussmann
PV-4A10F85L
CHPV15L85
Not provide
For more details about the fuse and fuse holder, please refer to the below links.
The Walter fuse and fuse holder links:
http://www.walterfuse.com/pdf/powerfuse/powerfuse_wj30.pdf
http://www.walterfuse.com/pdf/holder/holder_wj-30h.pdf
The Littelfuse fuse and fuse holder links:
https://www.littelfuse.com/~/media/electrical/datasheets/fuses/solar-fuses/littelfuse_fuse_solar_spxv_datash
eet.pdf
https://www.littelfuse.com/~/media/electrical/datasheets/fuse-blocks-and-holders/dead-front-fuse-holders/lit
telfuse_fuse_holder_lfpxv_datasheet.pdf
https://www.littelfuse.com/~/media/electrical/datasheets/fuse-blocks-and-holders/littelfuse-fuse-holder-lpxv-
datasheet.pdf
The Bussmann fuse and fuse holder links:
Installation Manual
3
1
2
4
http://www.cooperindustries.com/content/dam/public/bussmann/Electrical/Resources/Catalogs/bus-ele-cat-
1007-flc-2018-sec-06-pv.pdf?_ga=2.127114697.571121133.1577416796-883900423.1577416796
(9)Mounting Instruction:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible.
Admissible DIN rail:TS35/7.5 or TS35/15
For rail fastening:
(a)Tilt the unit slightly rearwards.
(b)Fit the unit over top hat rail.
(c)Slide it downward until it hits the stop.
(d)Press against the bottom for locking.
(e)Shake the unit slightly to check the locking action.
(10)Installation clearancs : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended
when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is
recommended.
(11)The ambient temperature derating of 3.5°C/1000m with fan less models and of 5°C/1000m with fan models
for operating altitude higher than 2000m(6500fit).
(12)Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
(13)For any application note and IP water proof function installation caution, please refer our user manual before
using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
(14)Product Liability Disclaimer : For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer .aspx
(15)For other information about the products, please refer to www.meanwell.com for details.
"Click"
Installation Manual
Warning / Caution !!
“CAUTION:FOR USE IN A CONTROLLED ENVIRONMENT. REFER TO MANUAL FOR ENVIRONMENTAL CONDITION”
ATTENTION: A UTILISER DANS UN ENVIRONNEMENT CONTROLE. REFEREZ VOUS AU MANUEL POUR
LES CONDITIONS D’ENVIRONNEMENT.
(1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
(2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides
together is not allowed.
(3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection!
(4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids.
(5)Only install the unit in a pollution degree 2 environment (Note.1).
(6)Please do not install the unit in places with high moisture or near the water.
(7)The maximum operating temperature is 80°C for the DDRH-60, please do not install the unit in places with
high ambient temperature or near fire source.
(8)Output current and output wattage must not exceed the rated value on its specification.
(9)Disconnect system from supply voltage:
Before commencing any installation, maintenance or modification work: Disconnect your system from
supply voltage. Make sure that inadvertent connection in circuit will be impossible!
Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become
conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as
control cabinets.
Manufacturer
:
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office
:
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
No.11, Jingu South Road, Huadong
Town, Huadu Distric, Guangzhou,
Gungzhou, China
Tel: +86-20-3773-7100
Web: www.meanwell.com.cn
China
SUZHOU MEAN WELL
TECHNOLOGY Co., LTD.
No.269 Changping Rd. , Huangdai
Town, Xiangcheng District
Suzhou, Jiangsu Province, China
Post Code: 215152
Tel: +86-512-6508-8600
Web: www.meanwell.cc
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT Amstelveen, The
Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Declaration of China RoHS Conformity
In order to reduce the impacts on the environment and take the more responsibility for protecting the
earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an
Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and
Electronic Products.
Environment Friendly Use Period Label
Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous
Substances in Electronic and Electrical Products
Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly
Use Period of Electronic Information ProductsAppendix B, adopting
table look-up to verify the Environment Friendly Use Period
Names and Contents of Hazardous Substances Lists
Part Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium
(Cr6+)
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
PCB and its
components
X
O
X
O
O
O
Metal structure
parts
X
O
O
O
O
O
Plastic structure
parts
O
O
O
O
O
O
Accessories
O
O
O
O
O
O
Cables
X
O
O
O
O
O
O: The concentration of the hazardous substances within the homogeneous material of that product is less than
the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the
concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.
Declaration of China VOC Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL is confirming and announcing the conformity to
China’s Standardization Administration Releases VOC Standards
Standard No. Name of the Standard
GB 30981-2020 Limit of harmful substances of industrial protective coatings
GB 33372-2020 Limits for volatile organic compounds content in adhesive
GB 38507-2020 Limits for volatile organic compounds (VOCs) In printing ink
GB 38508-2020 Limits for volatile organic compounds content in cleaning agents
Declaration of Five PBT TSCA Conformity
In order to reduce the impacts on the environment and take the more responsibility
for protecting the earth, MEAN WELL hereby confirms that MEAN WELL product
series comply with Use and Risk Management for Five PBT Chemicals under TSCA
section 6(h)
CAS No.
Substance Name
1163-19-5
Decabromodiphenyl ether (DecaBDE)
68937-41-7
Phenol, isopropylated, phosphate (3:1)
PIP (3:1)
732-26-3
2,4,6-Tris (tert-butyl) phenol (2,4,6-TTBP)
133-49-3
Pentachlorothiophenol (PCTP)
87-68-3
Hexachlorobutadiene (HCBD)

This manual suits for next models

47

Other Meanwell Media Converter manuals

Meanwell DDRH-120-12 User manual

Meanwell

Meanwell DDRH-120-12 User manual

Meanwell SD-15 Series User manual

Meanwell

Meanwell SD-15 Series User manual

Meanwell DDRH-60-5 User manual

Meanwell

Meanwell DDRH-60-5 User manual

Meanwell SKM10 Series User manual

Meanwell

Meanwell SKM10 Series User manual

Meanwell DDR-240 Series User manual

Meanwell

Meanwell DDR-240 Series User manual

Meanwell RSDH-150 Series User manual

Meanwell

Meanwell RSDH-150 Series User manual

Popular Media Converter manuals by other brands

ADF Web HD67235-A1 user manual

ADF Web

ADF Web HD67235-A1 user manual

Yamaha UX96 Mode d'emploi

Yamaha

Yamaha UX96 Mode d'emploi

SPL Diamond user manual

SPL

SPL Diamond user manual

Neptune Technology ProCoder R900i Installation and maintenance guide

Neptune Technology

Neptune Technology ProCoder R900i Installation and maintenance guide

DJ-Tech cd encoder 10 user manual

DJ-Tech

DJ-Tech cd encoder 10 user manual

Erone SEL39R433-PP4 Instruction Notice

Erone

Erone SEL39R433-PP4 Instruction Notice

ASTRO HDQ 1 operating manual

ASTRO

ASTRO HDQ 1 operating manual

Kramer VM-4DH user manual

Kramer

Kramer VM-4DH user manual

StarTech.com MCM110SC Specifications

StarTech.com

StarTech.com MCM110SC Specifications

evertz HD9690 Series instruction manual

evertz

evertz HD9690 Series instruction manual

Novar IMC-101 installation instructions

Novar

Novar IMC-101 installation instructions

StarTech.com 8STET91000LCOAM manual

StarTech.com

StarTech.com 8STET91000LCOAM manual

Raisecom RC906-FXE1-M user manual

Raisecom

Raisecom RC906-FXE1-M user manual

ADF Web HD67672-IP-2-A1 user manual

ADF Web

ADF Web HD67672-IP-2-A1 user manual

Linear Technology LTC2635 Demo Manual

Linear Technology

Linear Technology LTC2635 Demo Manual

Audio Authority 1366 user manual

Audio Authority

Audio Authority 1366 user manual

Techlogix TL-DA12-HD2 user manual

Techlogix

Techlogix TL-DA12-HD2 user manual

Renishaw QUANTiC RTLC40-S installation guide

Renishaw

Renishaw QUANTiC RTLC40-S installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.