8
Periodic Maintenance
The periodic maintenance required by the unit will depend on the amount of dust or
contaminants in the operating environment. The high voltage emitter pins and grill
will typically require monthly cleaning. However, the optimum frequency of cleaning
will depend upon the operating environment and the number of hours of operation.
Periodic cleaning should not be postponed until the Inspect Pins lamp becomes
illuminated. However if the Inspect Pins lamp does illuminate then the unit should be
cleaned as soon as possible.
Touching or cleaning of the emitter pins or grill should only be performed with
the unit turned o and isolated from the electrical supply.
Access to the pins is achieved by removing the door retaining screws and hinging
it open. Cleaning of the pins and grill should be carried out using a cotton swab
dampened in isopropanol. Operators should avoid touching the pins with their ngers
as they are very sharp.
The emitter pins must be allowed to dry before the unit is switched back on
(typically 5 minutes)
If the pins are found to be worn and require replacement, the pins should be removed
using a pair of round nose pliers and replacements tted. Replacement pins are
available from Meech.
CalibrationThis should be completed by Authorised
Personnel only
The Model 221 has been factory calibrated in accordance with ANSI-EOS/ESD-
S3.1-1991. to achieve a maximum balanced ion output in standard applications. It is
calibrated using a charge plate monitor at maximum fan speed with the charge plate
450mm from the blower grill.