manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Mega
  6. •
  7. UPS
  8. •
  9. Mega MEg101.4 User manual

Mega MEg101.4 User manual

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

CyberPower RB12120X2A user manual

CyberPower

CyberPower RB12120X2A user manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

CyberPower CP585LCD user manual

CyberPower

CyberPower CP585LCD user manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

CyberPower Office Tower Series UPS 1000 user manual

CyberPower

CyberPower Office Tower Series UPS 1000 user manual

CyberPower BM100 quick start guide

CyberPower

CyberPower BM100 quick start guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MEgA – Měřící Energetické Aparáty, a.s.MEgA – Měřící Energetické Aparáty, a.s.
664 31 Česká 390664 31 Česká 390
Czech RepublicCzech Republic
Uninterruptible power supply
Supply MEg101.4
Uninterruptible power supply Supply MEg101.4
3
Uninterruptible power supply
MEg101.4
1/ CHARACTERISTICS
e uninterruptible power supply MEg101.4 is designed for feeding the measuring and
communication devices with 12 V nominal supply voltage. Its core is a High-frequen-
cy voltage converter that converts the supply voltage with high eciency to the output
uninterruptible DC voltage. When the supply voltage is interrupted, the power supply
delivers the output DC voltage from the internal supercapacitor for 3 sec at least or if
an external a 12 V lead-acid accumulator is connected, it will extend duration of power
supply according its capacity. If necessary, the uninterruptible power on the output of
the power supply unit can be blocked. e output of the power supply is equipped with
overcurrent protection and with a replaceable fuse on the input accessible from outside.
e accumulator circuit is also equipped with a replaceable fuses. MEg101.4 also meets
requirements of overvoltage category CAT IV / 300 V and therefore is suitable do LV dis-
tribution networks.
Měřící Energetické Aparáty
4
2/ TECHNICAL DATA
Power supply MEg101.4 input
Supply voltage: DC AC, f = 50 Hz
Rated voltage: 220 VDC 230 VAC
Minimum voltage: 150 VDC 150 VAC
Maximum voltage: 300 VDC 300 VAC
Rated current: 180 mADC 180 mAAC
Maximum current: 250 mADC 250 mAAC
Input power: 20 W / 45 VA
Insulation voltage: 5.4 kVAC
Overvoltage category: CAT IV / 300 VAC
Fuse FU1: FSK001 / 1 A-T
Accumulator
Type, rated voltage, capacity: lead-acid, gel type, 12 V, 1.2 Ah to 24 Ah
Fuse FU2: FSK001 / 2,5 A-T
Fuse FU3: FSK001 / 0,16 A-T
Power supply MEg101.4 output
Rated output voltage: 12 VDC
Output voltage range: 10 VDC to 14 VDC
Maximum output current,
terminals 2, 3: 1.3 A
Rated power: 15 W
Uninterrupted power supply period: 3 sec. / without external accumulator connected
up to 4 hrs / when 6 Ah accumulator is connected
Max. accumulator charging current,
AKU, terminals 35, 36: 0.2 A
Starting current inrush: 5 A / 3 ms
Uninterruptible power supply Supply MEg101.4
5
Design data
Length × width × height: 108 × 90 × 63 mm
Weight: 0.4 kg
Installation: DIN rail TS 35
Terminal block,
max. wire cross-section: 4 mm2
Operating conditions
Rated operating temperature: 22 °C
Operating temperature range: -20 °C to +55 °C
Operation: interior, with cover panel of terminals
outdoor, in waterproof case
Protection rating: IP00
Relative humidity: 20 % to 90 %
Altitude: up to 2 000 m
Operating position: vertical with ventilation openings on upper side,
installation on DIN rail
Safety: EN 61010-1:2010
EMC: EN 61326-1:2013
Pollution degree: 2
Měřící Energetické Aparáty
6
3/ EXPLANATION OF SYMBOLS IN USER MANUAL
FOR POWER SUPPLY MEg101.4
Danger, electric shock risk
Note in documentation / Danger, risk of danger
Ground, grounding terminal for RF grounding
IP kód Degree of protection provided by enclosure
e product is intended for recycling and collection spots
Declaration of Conformity – European Community
4/ CONSTRUCTION
e uninterruptible power Supply MEg101.4 is built in a plastic case made of self-extin-
guishing polycarbonate. e power supply is installed on the DIN rail TS 35 using upper
or lower spring latches. e power supply can be located in the case together with the
external accumulator.
Global conguration of the MEg101.4 power supply is on Fig. 1. e LED indicator RUN
is on the unit's panel, indicating the presence of 12 VDC voltage on the output of the units on
terminals with label OUTPUT. e group of terminals POWER with AC or DC supply
voltage and the group of OUTPUT terminals with 12 VDC output voltage and blocking
are located on the lower part of the unit and their denotation and explanation are given
in Tab. 1. e group of AKU terminals is designed for possible connection of an external
accumulator and it is found on the upper part of the unit. Maximum cross-section of the
connected wire is 4 mm2. e replaceable input fuse FU1 is in socket under the screwed
cover next to the input supply POWER voltage terminals. Both replaceable fuses FU2 and
FU3 in the external accumulator circuit are found under the cover located next to the group
of AKU terminals. e rated voltage of the external gel gas-tight lead-acid accumulator is
12 VDC and the accumulator can have the capacity up to 24 Ah. Without the external accu-
mulator, the supercapacitors used in the uninterruptible power supply provide power with
the voltage drop from 12 V to 10 V for 3 sec at 15 W load.
Uninterruptible power supply Supply MEg101.4
7
Tab. 1: Power supply MEg101.4 terminals
Terminal
number
Terminal
denotation
Terminal description
1 OUTPUT STOP Uninterruptible output voltage blocking
2 OUTPUT GND Output ground of power supply MEg101.4
3 OUTPUT +12 V Uninterruptible output voltage +12 VDC
14 POWER L
POWER +
AC phase conductor or
DC supply voltage positive pole
16 POWER N
POWER –
AC neutral conductor or
DC supply voltage negative pole
18 POWER RF grounding
35 AKU +Positive pole of the 12 V lead-acid accumulator
36 AKU –Negative pole of the 12 V lead-acid accumulator
Fig. 1: Power supply MEg101.4 unit
Poz. Skl. číslo Popis Ks Poznámka
Měř.: Datum: Konstrukce: Schválil: Datum posl. revize:
Číslo výkresu: Skl. číslo:
Název:
MEgA -
Měřící Energetické Aparáty, a.s.
1
1:1 Kreslil:
List:
Zdeněk Kružík
FU2
FU1
FU3
On the left side of the MEg101.4 power supply unit, there is a rating label with detailed
information about the power supply, see the example in Fig. 2.
Měřící Energetické Aparáty
8
Obr. 2: MEg101.4 rating label example
MEg101.4
Made in Czech Republic
Supply
Power: U =230V , (150-300) V , f =50Hz
n
Output: U = 12V , (10-14)V
n
max
U =220V , (150-300) V
n
I =180mA , I =250mA
n
max
I =1,5 A (term.2-3 and 36-35)
total
I =0,2 A (term.36-35)
n
5/ SAFETY INFORMATION
Maximum attention must be paid to this information
Warnings draw attention to the facts, constituting safety risks to the operator.
Cautions indicate conditions and facts that may cause damage to the uninterrup-
tible power supply MEg101.4.
• e operator engaged in installation of the power supply MEg101.4, commissio-
ning, maintenance and dismantling must be equipped with personal protective
equipment against electrical shock and must use other protection devices as well.
• e operator engaged in installation of the power supply MEg101.4, commissio-
ning, maintenance and disassembly must have qualications for work near dange-
rous voltages. e operator must also be trained to administer rst aid.
• e power supply MEg101.4 may be operated by skilled personnel only.
• e power supply MEg101.4 may be connected to supply by permanent maximum
voltages 300 VAC and 300 VDC, otherwise there is a risk of electrical injury.
• It is necessary to incorporate circuit breakers in the circuits of the power supply
MEg101.4 with respect to the type of supply voltage, see Fig. 4.
• Repairs of the power supply MEg101.4 may only be carried out by the manufactu-
rer or service organizations authorized by the manufacturer.
• e replacement of FU1 fuse for AC or DC supply voltage may be carried out only
with the supply voltage switched o.
• When connecting an external 12 V battery the terminals must not to be short circu-
ited and as the last the inlet connects to positive pole of the supply source.
Uninterruptible power supply Supply MEg101.4
9
6/ INSTALLATION AND PUTTING IN OPERATION
If the uninterruptible power supply MEg101.4 is used in ways other than origi-
nally intended, the protection provided by the power supply may be impaired.
e uninterruptible power supply MEg101.4 is a Class A product designed
for industrial environments. It may cause radio interference in other environ-
ments.
e power supply MEg101.4 unit is placed only in vertical position and is always
installed on DIN rail (35 mm) in the case or under the terminal cover panel so that
protection rating, re resistance, mechanical impact resistance for the required
environment can be reached. Due to protection against electrical injury and me-
chanical impact resistance improvement require overlapping the terminals cover
by the cover panel.
e uninterruptible power supply MEg101.4 may only be installed by the per-
son authorized to work with input voltage and equipped with personal protection
equipment against electrical injury and familiarized with the instruction manual.
e denotation of supply terminals in the POWER L and N section applies to AC
mains supply and the denotation + and – applies to DC supply voltage.
e power supply MEg101.4s with the external lead-acid accumulator is delivered
unconnected. When handling the accumulator, its output terminals must not be
short-circuited. When installing the MEg101.4 set with the external accumulator,
the correct polarity must be respected. In case of incorrect connection of the
accumulator to the power supply terminals (terminal 35 is + pole, terminal 36 is
–pole), the fuse FU2 (2.5 A) will burn out. In case of short-circuit of the accumu-
lator terminals (terminals 35 and 36) the fuse FU3 (0.16 A) will burn out.
Regardless of the power supply voltage direction or way of grounding (DC or AC,
none or one grounded pole), it is neccessary to connect both supplying wires via
fuse switch-disconnector according to Fig. 4.
It is also neccessary to place the fuse switch-disconnector as close as possible and
as easily reachable as possible.
e uninterruptible power supply MEg101.4 is installed always on the DIN rail TS 35.
e MEg101.4 is always in vertical position with ventilation openings on upper side and
the inscription on the unit's panel is readable from left to right, see Fig. 3.
Power supply MEg101.4 wiring is in Fig. 4.
Měřící Energetické Aparáty
10
Fig. 3: Example of installation source unit in vertical position to box with DIN rail
e power supply terminal (18) for RF grounding must be connected to the grounding
system in the power supply installation site.
Based on the type of power supply, AC or DC supply voltage is brought to terminals (14)
and (16). e power supply MEg101.4 can be fed by AC voltage ranging from 150 VAC
to 300 VAC.
e power supply MEg101.4 can be fed by DC voltage ranging from 150 VDC to 300 VDC.
When the uninterruptible power supply MEg101.4 is used for feeding external devices,
the uninterruptible output voltage is +12 V / max. 1.3 A is available at terminals (2) and
(3). e terminal (1) connected with terminal (2) is used for blocking the uninterruptible
supply voltage. In this way, it is possible to block unnecessary discharging of the external
accumulator, e.g. during functional checks and inspections.
After connection of the input supply voltage, the LED indicator RUN on the power
supply panel is lit and the output DC voltage Unom = +12 VDC is available on the output
and internal supercapacitors and also alternatively the external lead-acid accumulator
connected are charged at the same time. When the supply voltage is interrupted, the
power supply unit is fed by DC output voltage ranging from 10 V to 14 V for the period of