MegaLife ML-PC07AM-K5NNA2B User manual

Owner's Manual
Original Instructions
Portable air conditioner
Model: ML-PC07AM-K5NNA2B
ML-PC07AM-K5NNA2C
ML-PC07AM-K5NNA2D
ML-PC09AM-K5NNA2B
ML-PC09AM-K5NNA2C
Thank you for choosing our product.
Please read this Owner’s Manual carefully before operation and
retain it for future reference.

Content
ronmental safe recycling.
R290: 3
This marking indicates that this product should not be disposed with other household wastes
Operation Notices
The Refrigerant .......................................................................................................1
Safety Warning ........................................................................................................2
throughout the EU. To prevent possible harm to the environment or human health from un-
controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate-
rial resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for envi-
Part's Name .............................................................................................................4
Operation Guide
Operation Environment ...........................................................................................3
Operation Introduction for Control Panel .................................................................5
Buttons on Remote Controller .................................................................................7
Introduction for Icons on Display Screen .................................................................7
Introduction for Buttons on Remote Controller .........................................................8
Maintenance
Replacement of Batteries in Remote Controller ....................................................10
Function Introduction for Combination Buttons ......................................................10
Malfunction
Clean and Maintenance.........................................................................................11
Installation Notice
Malfunction Analysis .............................................................................................13
Preparation before Installation ..............................................................................18
Installation
Installation Precaution ...........................................................................................16
Install Wire Hook ...................................................................................................19
Drain Water ...........................................................................................................20
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Attached Sheet
Operation Test ......................................................................................................24
Specialist’s Manual................................................................................................25
Installation of Heat Discharge Pipe ......................................................................22
Electric Schematic Diagram...................................................................................24

Explanation of Symbols
1.Damage the product due to improper use or misuse of the product;
2.Alter, change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer;
After verification, the defects are due to improper operation during transportation
of product;
4.
Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
5.
After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
6.
The damage is caused by natural calamities, bad using environment or force
majeure.
7.
After verification, the defect of product is directly caused by corrosive gas;3.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or
property loss is caused by the following reasons.
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
DANGER
WARNING
CAUTION
N OT IC E
If it needs to install, move or maintain the air conditioner, please contact dealer
or local service center to conduct it at first. Air conditioner must be installed,
moved or maintained by appointed unit. Otherwise, it may cause serious
damage or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance,
or disassembly, it should be handled by certified professionals or otherwise in
compliance with local laws and regulations.

The Refrigerant
WARNING
Appliance filled with flammable gas R290.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R290, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can lead to explosion
under certain conditions.
Compared to common refrigerants, R290 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R290
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
1
Before install and use the appliance, read the owner’s manual first.
Appliance filled with flammable gas R290.
Appliance shall be installed, operated and stored in a room with a floor area:
The appliance shall be stored in a room without continuously operating ignition sources .
(for example: open flames, an operating gas appliance or an operating electric heater.
)
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
The appliance shall be stored so as to prevent mechanical damage from occurring.
Ducts connected to an appliance shall not contain an ignition source.
Keep any required ventilation openings clear of obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
Servicing shall be performed only as recommended by the manufacturer.
Should repair be necessary, contact your nearest authorized Service Centre.
Any repairs carried out by unqualified personnel may be dangerous.
Compliance with national gas regulations shall be observed.
Read specialist’s manual.
Min. floor area (m )Model
4
11
ML-PC07AM-K5NNA2B
ML-PC07AM-K5NNA2C, ML-PC07AM-K5NNA2D
ML-PC09AM-K5NNA2B, ML-PC09AM-K5NNA2C

2
Safety Warning
● Before operation, please confirm whether power specification
● Before cleaning or maintaining the air conditioner, please turn off
air conditioner and pull out the power plug.
complies with that on nameplate.
●
Please use the grounded power. Make sure the grounding is reliable.
● Do not insert or pull out the power plug with wet hands.
disconnect power at once and then contact local dealer.
● If abnormal condition occurs (e.g. burned smell), please
● When nobody is taking care of the unit, please turn it off and
remove the power plug or disconnect power.
● Do not splash or pour water on air conditioner. Otherwise, it may
cause short circuit or damage to air conditioner.
portable room air conditioner without supervision.
●
If drainage hose is used, ambient temperature can't be lower than
0Otherwise, it will cause water leakage to air conditioner.
● Prohibit inserting any objects into the air conditioner.
● Do not repair or disassemble the air conditioner by yourself.
● Do not put or hang dripping objects above the air conditioner.
● Keep children from playing or climbing on the air conditioner.
● Children and disabled people are not allowed to use the
● Far away from fire source, inflammable and explosive objects.
● Prohibit operating heating equipment around the air conditioner.
● Prohibit operating the unit in the bathroom or laundry room.
● Make sure the power cord hasn’t been pressed by hard objects.
● Do not pull or drag the power cord to pull out the power plug or
move the air conditioner.
● Cleaning and user maintenance shall not be made by children
without supervision.
● This appliance can be used by children aged from 8 years and
● Children shall not play with the appliance.
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
in order to avoid a hazard.
● If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person

Note:
Graphics in this manual are only for reference. Please refer to actual products
for specific details.
Safety Warning
Operation Environment
● This air conditioner can only be used for family, not for
commercial industry.
● The appliance is for indoor use only.
● The air conditioner must be operated within the temperature range:
16°C ~ 35°C.
● The appliance must be positioned so that the plug is accessible.
● Reserved space around the air conditioner should be 12″(30cm)
at least.
● Do not operate the air conditioner at humid environment.
● During operation, close doors and windows to improve cooling effect.
● Please keep air inlet and air outlet clean, no obstacles.
to avoid noise and vibration.
● Please put the air conditioner at smooth and flat ground for operation
● This air conditioner is equipped with castors. Castors should slide
at smooth and flat ground.
● Prohibit inclining or turning over the air conditioner. If there’s abnor-
mity,please disconnect power immediately and contact dealer.
● Avoid direct sunshine.
30cm 30cm
30cm
3
● Do not use an extension cord.
●
Do not through sundries into the air duct. If there are sundries get
into the air duct, please contact the professionals to deal with it.

Part's Name
1
22
3
6
4
Remote controller
4
Guide louver
1Controller panel
Joint
NOTICE:
Heat discharge pipe and other installation accessories can't be discarded.
3Swing louver
4Castor
5Filter
10 Wire-fixing hook
7Heat discharge pipe
8Rear Clip
9Plug of power cord
876
9
5
10
FAN
AUTO
OPER
Fan Swing
ModeOn/Off
Sleep Timer
Health WiFi

5
Name of control panel
Operation of control panel
Note:
●
●
that, you can operate the air conditioner by the control panel.
After putting through the power, the air conditioner will give out a sound. After
Under ON status, after each pressing of the button on control panel, the air
●
conditioner will give out a sound. Meanwhile, corresponding indicator on control
panel will be bright.
Under OFF status, dual-8 nixie tube on control panel won’t display.
Under ON status, dual-8 nixie tube on control panel will display set temperature
under cooling mode, while it won’t display under other modes.
Pressing this button can turn on or turn off the air conditioner.
Under cooling mode, press “+” or “-” button to increase or decrease set temperature by
1°C. Set temperature range is 16°C~30°C. Under drying or fan mode, this button
is invalid.
ON/OFF button
+ / - button
1
2
Operation Introduction for Control Panel
ON/OFF button
Fan mode indicator
Mode button
Fan speed indicator
+ / - button Dual-8 nixie tube Cool mode indicator
Dry mode indicator
Sleep button
Fan button
Wifi button

6
Press this button and the mode will circulate according to below sequence:
COOL →DRY
FAN
→
→
COOL: Under this mode, cooling mode indicator is bright. Dual-8 nix syalpsidebutei
set temperature. Temperature setting range is 16
°C
~30
°C
.
DRY: Under this mode, drying mode indicator is bright. Dual-8 nixie tube won’t
display.
FAN: Under this mode, the air conditioner only blow fan. Fan indicator is bright.
Dual-8 nixie tube won’t display.
Mode button
3
Press this button and the fan speed will circulate as “low speed→ medium speed →
high speed→ auto fan→ low speed”.
Fan button
4
Operation Introduction for Control Panel
6Sleep button
Press sleep button to enter into sleep mode. If the controller operates at cooling
mode, after sleep mode is started up, preset temperature will increase by 2°F(1°C)
within 1 hour ;preset temperature will increase by 4°F(2°C) within 2 hours and then
the unit will operate at this temperature all the time; Sleep function is not available
for fan mode, drying mode. If sleep function is started up, the upper indicator will
keep the display status. Others, it won’t be displayed.
5Wifi button
After the unit is powered up, press WIFI button to turn on or off WIFI function.
Press and hold the button for 10s to reset WIFI function.

FAN
AUTO
OPER
Fan Swing
ModeOn/Off
Sleep Timer
Health WiFi
3
12
Buttons on remote controller
34
57
69
8
7
+ / - button
Introduction for icons on display screen
1On/Off button
2Mode button
4Swing button
5Fan button
6Sleep button
7Timer button
8Health button
9 WiFi button
FAN
AUTO
OPER
Set fan speed
Set time
Send signal
NOTICE: “
do not. Please refer to the actual models.
Child lock
Set temperature
health function
ventilation operation
8℃heating function
Operation mode
Auto mode
Cool mode
Dry mode
TIMER ON /TIMER OFF
Fan modeLight function
X-fan mode
Heat mode
I feel function
Sleep mode
Up & down swing
Temp. display type
:Indoor ambient temp.
” This is a general remote controller. Some models have this function while some
:Set temp.
:Outdoor ambient temp.
Turbo mode
(Not available for this unit)
(Not available for this unit)

Introduction for buttons on remote controller
Note:
MODE button
2
1 ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.
Press this button can your required operation mode in turn. Corresponding indicator
will be on.
● This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
8
Dry HeatCoolAuto
Fan
Only
● Cool: Under this mode, air conditioner operates under cooling mode. Cooling
indicator will be on. Press “Fan Speed” button can adjust the fan speed.
● Auto: Under this mode, the unit will operate automatically according to ex-factory
setting. In this case, set temperature cannot be adjusted.
● Heat: Under this mode, air conditioner operates under heating mode. Press “Fan
●
Speed” button can adjust the fan speed.(Cooling only unit won’t receive heating
mode signal. If setting heat mode with remote controller, press ON/OFF button
can’t start up the unit).
Fan Only: Under this mode, air conditioner will not cool or heat, only blow wind.
Fan indicator will be on. Press “Fan Speed” button can adjust the fan speed.
● Dry: Under this mode, the unit runs in low fan speed for dehumidification and the
corresponding indicator is on; under dry mode, the fan speed cannot be adjusted.
+ / - button
3
Pressing “+” or “-” button once will increase or decrease set temperature by 1°F(°C).
Hold “+” or “-” button for 2s, set temperature on remote controller will change
quickly.
●
●
Release the button after your required set temperature is reached.
Under timer setting status, after each pressing of “+” or “-” button, time will increase
or decrease 0.5h . Hold “ + ” or “-” button, 2s later, time displayed on dual-8 nixie
tube will change quickly. Loosen the button until the time is reached to your set
time.

Introduction for buttons on remote controller
4Swing button
Not available for this unit.
Not available for this unit.
6Sleep button
9
NOTE: There are 3 speeds for the Fan Speed of this model.
5Fan button
This button is used for setting Fan Speed in the sequence that goes from AUTO,
, , to then back to Auto.
Auto
Speed 1 Speed 2
Speed 3
Press this button to go into the Sleep operation mode. Press it again to cancel this
function. This function is available in COOL, HEAT (Only for models with heating
function) mode to maintain the most comfortable temperature for you.
8Health button
7Timer button
Under ON status, press this button to set timer OFF; Under OFF status, press
this button to set timer ON.
Press this button once and the characters of HOUR ON (OFF) will flash to be
displayed. Meanwhile, press “+” button or “-” button to adjust timer setting (time
will change quickly if holding “+” or “-” button). Time setting range is 0.5~24hours.
Press this button again to confirm timer setting and the characters of HOUR ON
(OFF)will stop flashing.
If the characters are flashing but you haven’t press timer button,timer setting status
will be quit after 5s.If timer is confirmer, press this button again to cancel timer.
WiFi button
Press " WiFi " button to turn on WiFi function, " WiFi " icon will be displayed on the
remote controller;
Hold " WiFi " button for 5s to turn off WiFi function and " WiFi " icon will disappear.
Under off status, press "MODE" and " WiFi " buttons simultaneously for 1s, WiFi
module will restore factory settings.

1.
the lamp is defaulted on.
are correct.
signal sender battery
reinstall
NOTICE
conditioner when using the remote controller.
batteries.

11
Clean and Maintenance
Clean outer case and grille
Clean grille: Use cleaner or soft brush to clean it.
Clean outer case:
If there's dust on the surface of outer case, please use soft towel
to wipe it. If the outer case is very dirty (such as grease), please
use neutral abluent to wipe it.
1
2
3
Use cleaner or water to clean the
After the filter is cleaned and
dried, reinstall it well.
as grease), use warm water 40°C
melted with neutral abluent to
clean it and then put at shady
place to dry it.
NOTICE
dust in the operation environment, you can increase clean frequency.
●
●
●
●
Do not use liquid or corrosive detergent clean the appliance and do not spla-
sh water or other liquid onto it, otherwise,it may damage the plastic compon-
ents,even cause electric shock.
WARNING
Before cleaning the air conditioner, please turn off the unit and disconnect
power. Otherwise, it may cause electric shock.
Do not wash air conditioner with water. Otherwise, it may cause electric
shock.
Do not use volatile liquid (such as thinner or gas) to clean the air conditioner.
Otherwise, it may damage the appearance of air conditioner.

Clean and Maintenance
Clean heat discharge pipe
Remove the heat discharge pipe from air conditioner, clean and dry it , and then
reinstall it. (For the method of installation and removal , please refer to the
instruction for "Installation and disassembly of heat discharge pipe").
Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether plug and socket are in good condition.
3. Check whether lter is clean.
4. Check whether batteries are installed in remote controller.
5. Check whether joint, window bracket and heat discharge pipe are installed tightly.
6. Check whether heat discharge pipe is damaged.
Checking after use-season
1. Disconnect power supply.
2. Clean lter and outer case.
3. Remove dust and sundries on the air conditioner.
4.
Eliminate accumulated water in chassis (refer to the section of "Drainage way"
for details).
5. Check whether window bracket is damaged or not. If yes, please contact dealer.
Long-time storage
If you don't use the air conditioner for a long time, please maintain it by following
steps for good performance:
● Make sure there's no accumulated water in chassis and the heat discharge pipe is
disassembled.
● Pull out the plug and wrap the power cord.
● Clean the air conditioner and pack it well to prevent dust.
Notice for recovery
● Many packing materials are recyclable materials. Please deal with them through
local recycle bin.
● If you want to throw away the air conditioner, please contact local division or
consultant service center for the correct disposal method.
12

Malfunction Analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualied professionals.
Phenomenon Troubleshooting Solution
Air conditioner
can't operate
Air conditioner
can't receive
signal from
remote contr-
oller or remote
controller is
not sensible.
Poor cooling
(heating)
● Power failure?
● Whether the unit is interfered
seriously (such as static pres-
sure, unstable voltage)?
● Whether remote controller is
within the receiving range?
● Whether it's blocked by obst-
acles?
● Is sensitivity of remote contr-
oller low?
● Whether there’s uorescence
lamp in the room?
● Is the power too low?
●
Whether the air lter is too dirty?
●
Whether the set temperature is
proper?
● Whether door and window are
closed?
● Is plug loose?
● Whether the air switch is trip-
ped off or fuse is burnt?
● Is there's malfunction for the
circuit?
● Whether the unit is restarted up
after stopping immediately?
● Wait after power recovery.
● Please pull out the plug. Ins-
ert the plug after about 3min,
and then turn on the unit.
●
The receiving range of remote
controller is 8m. Do not exce-
ed this range.
● Remove the obstacles.
● Check the batteries of remote
controller. If the power is low,
please replace the batteries.
● Move the remote controller
close to air conditioner.
●
Turn off the uorescence lamp
and try it again.
●
Wait after voltage is resumed.
● Clean the air lter.
● Adjust the temperature.
● Close door and window.
● Reinsert the plug.
● Ask professional person to
replace air switch or fuse.
● Ask professional person to
replace circuit.
● Wait for 3min, and then turn
on the unit again.
13

Phenomenon Troubleshooting Solution
Set tempera-
ture can't be
adjusted.
● Whether the unit operates un-
der auto mode?
● Whether the required temper-
ature exceeds the temperature
setting range?
●Temperature can't be adjus-
ted
under auto mode.
●Temperature set-
ting range: 16°C-30°C .
Malfunction Analysis
● Whether air outlet or air inlet is
blocked?
● Under heating mode, whether
indoor temperature is reached
to set temperature?
● Whether heating mode is sta-
rted up just now?
● Whether evaporator is defros-
ted? (observe it by pulling out
● Eliminate the obstacles.
● The unit will stop blowing
fan after reaching set
temperature.
● In order to prevent cold air,
air conditioner will delay for a
while to be started up, which
is the normal phenomenon.
● It's the normal phenomenon.
Air conditioner is defrosting.
will resume operation.
No air blowed
out from air
conditioner
There's off the room, such as furniture,
cigarette etc. source.
There's abnor-
mal sound du-
ring operation
● Whether the unit is interfered
by thunder, radio, etc?
● Disconnect power, put thro-
ugh the power again, and
then turn on the unit again.
You can heard
sound
● Whether the unit is turned on
or turned off just now? rigerant inside the air condit-
ioner, which is the normal
phenomenon.
You can heard
the sound of
"PAPA"
● Whether the unit is turned on
or turned off just now?
●Heat expansion or shrinkage
for the panel due to change
of temperature, which cause
friction sound.
14

15
Malfunction Analysis
Malfunction code
●
If there're following phenomenon, please turn off the air conditioner and discon-
●
nect the power immediately, and then contact dealer immediately.
→ Power cord is overheating or damaged.
→Abnormal sound during operation.
→ Water leakage
WARNING
If operate the air conditioner underabnormal condition, it may cause malfunc-
1.Pour out the water inside chassis.
2.If "H8" still exist, please contact professional person to
maintain the unit.
H8
E8、H3
Troubleshooting
Please contact qualified professionals for service.
Error code
F1、F2 F4 F0
1.Check if the unit is under high-temperature and high-humidi-
ty environment; if ambient temperature is too high, power off
the unit and then energize it for operation after the ambient
temperature drops to 35℃below.
2.Check if the evaporator and condenser are blocked by some
objects; if yes, take away the objects, power off the unit and
then energize it for operation.
3. If the malfunction still occur, please contact our after-sales
service center.

Installation Precaution
● Observe all governing codes and ordinances.
● Do not use damaged or non-standard power cord.
● Be caution during installation and maintenance. Prohibit incorrect operation
to prevent electric shock, casualty and other accidents.
WARNING
Selection of installation location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable,
please
consult the local dealer:
objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
Requirement of air conditioner
1. Air inlet should be far away from obstacles and do not put any objects near air outlet.
Otherwise, it will affect the radiation of heat discharge pipe.
2. Select a location where the noise and outflow air emitted by the outdoor unit will not affect
neighborhood.
3. Please try your best to keep far away from fluorescent lamp.
4.The appliance shall not be installed in the laundry.
16

Installation Precaution
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit.
3. For appliances with type Y attachment,the instructions shall contain the substance of
the following.If the supply cord is damaged,it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and
safety.
6. Do not put through the power before finishing installation.
7. The air conditioner is first class electric appliance. It must be properly grounding with
specialized grounding device by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.
8. The yellow-green wire or green wire in air conditioner is grounding wire, which can't be
used for other purposes.
9. The grounding resistance should comply with national electric safety regulations.
10. The appliance shall be installed in accordance with national wiring regulations.
17
WARNING:
This manual suits for next models
3
Table of contents
Other MegaLife Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Mitsubishi Electric
Mitsubishi Electric MSZ-DM25VA operating instructions

Haier
Haier AB052MAERA Operation & installation manual

Bimar
Bimar CP120 Instruction booklet

Airxcel
Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Frigidaire
Frigidaire LRA257ST21 Use & care guide

Hitachi
Hitachi RAS-10NHZ4(H) instruction manual