Memco Panachrome+ G3850 User manual

2. Installation
1. Secure the Panachrome+Controller in a suitable position on top of car to avoid damage.
2. Connect the Controller with the correct supply voltage and Inputs (see Fig 3 below)
3. Once the detectors are installed (see detector installation guide) it is important to ensure that the detector cables &
travelling cables (015 455) are secured to the door correctly, and that the travelling cables are routed to the Controller
correctly.
4. Connect the Transmit (TX) and Receive (RX) leads into the Controller sockets (see Fig 4). Note: either socket can be
used as the intelligent software will recognise which detector is plugged in.
5. On completion, carefully open and shut the doors by hand to check the travelling cable (015 455) has a smooth free
movement and is not liable to snag on anything during normal operation, otherwise there is a risk of cables being
damaged by the lift doors or caught when the lift moves.
6. With correct operation the display will show the following for a short time:
Note: the number following TX/RX is the number of PCBs in each detector.
If dierent, then please check all connections.
7. The Green and Red Indicators will be operated by software but, if required, external signalling can be used (see Table 1
and Fig 5).
Note: Before installing make sure the units are compatible to ensure reliable and trouble-free
operation:
The Panachrome+Controller G3850 is designed to operate with both Panachrome+2D Detectors [G2510 & G2540] and
Panachrome+3D detectors [G3510 & G3540] - check you have the correct items.
Memco Panachrome+
Universal Controller
Installation Guide
Ref No. G850 855ML GB Version 2
Panachrome+
TX 5 RX 5
1. Connections
Covers
To access the connections on the Controller it is necessary to remove the end covers protecting the terminals. The
terminals are a quick-connect screwless type.
The Right Hand Cover conceals the terminals for connecting the external speaker and detector sockets. The Left Hand
Cover is for the power, relays and external door signals (see Figs 1 and 2).

Left Hand Cover Right Hand Cover
End Plate
End plate release clip
Fixing position
Plug in
detector
extension
cables here (RX
and TX can
plug into either
socket)
Fig 1: Connections

To remove the end covers simply lift upwards.
Power, relays and external door signals
Terminal No. Function Comments
1 Earth
85 to 240VAC if powered via AC (for DC use 17 & 18)2 Neutral
3Live
4N/O
Relay 1 for door operator 250VAC, 24VDC at 5A5 COM
6N/C
7 N/O 1
Relay 2
8 COM 1
9 N/C 1
10 N/O 2
11 COM 2
12 N/C 2
13 D/C Door closing input (12 to 230 AC/DC).
Note: not polarised
14 D/C
15 D/O Door Opening input (12 to 230 AC/DC)
Note: not polarised
16 D/O
17 + +15 to 48VDC if powered via DC
18 - 0V
Release clip for
end plate
Terminal 1
Fig 2: Connections
Fig 3: Installation
Recessed button
Table 1

Detectors and External Speaker
The RX and TX can be plugged into either of the two 5-way DIN socket as the controller uses intelligent software to
determine which one has been connected.
An optional external speaker can be connected to the centre 2-way terminal block.
3. External Signals Wiring Examples
Door closing
signal and
common (0V)
Door opening
signal and
common (0V)
oooo
13 14 15 16
Door closing
signal and
common (0V)
Door opening
signal
oooo
13 14 15 16
Common can be joined
together at Panachrome+
Controller
oooo
13 14 15 16
Spare
contact on
door close
contactor
12 - 230VAC
or DC supply
Spare
contact on
door open
contactor
Common (0V)
Fig 4: Installation
Fig 5: Installation

4. Menu Navigation
Panachrome+settings can be changed by using the 4-button keypad and screen.
Key Function
Go back/cancel
▼Menu and value down
▲Menu and value up
Menu item select and conrm
To enter the settings menu rst press ▼.
Press ▼and ▲to go to the desired function then use to select. Some of the functions have multiple choices so use ▼
and ▲to view. An active function is indicated by a *symbol.
Note: the bottom line on the display is the active function or menu item. The top row displays ‘Panachrome+’ when the
rst level is selected then changes when sub-menus are accessed.
For example:
First level Second Level
Panachrome
+
Visible Diodes
There are 3 types of tones when navigating through the menus:
1. Single short high pitched – menu navigation
2. Single low pitch tone – incorrect selection
3. Three short tones – settings change conrmation
Visible Diodes
▼ Mode
Prole Selection:
The Controller must be congured for the correct width. Incorrect choice may result in regular false triggers, particularly
near to closed.
For initial installation, press the down key until menu indicates Quick Cong, Select this, then down until the correct
model is chosen. When selected, the Controller will emit a series of beeps. This also sets all congurations to factory
settings.
To change just the prole setting, select Advanced, Prole Width, then 10mm or 43mm.

5. Menu Navigation
Language
English
Language selection
French
German
Spanish
Japanese
Czech
Quick Config
G3510
Quick Congurator for Product Versions
(2 = 2D, 3 = 3D) (10 = 10mm, 40 = 43mm)
G2510
G3540
G2540
Visible Diodes
Mode
Normal
Green ON when the detectors are triggered and the doors are
open/opening. Flashing red when the doors are closing and
solid red when closed.
External Inp.
Enables control of the visible diodes by the open and close
door signals. Choose whether this is activated by the rising or
falling edge of an external signal (see Section 6 for details).
Demo Continual demo sequence of green and red diodes.
Trigger Visible diodes will change from green to red when the
detectors are triggered.
Test For internal use only.
Off Turns o visible diodes.
Sides
Both On This controls which detector, either TX or RX have their visible
diodes ON or OFF. The default is both TX and RX visible
diodes ON.
TX only ON
RX only ON
Ext. Inp. Open
Rising Edge Door open signal rising or falling edge signal (see Section 6 for
details).
Falling Edge
Ext. Inp. Close
Rising Edge Door closing signal rising or falling edge signal (see Section 6
for details).
Falling Edge
Green On Time Sets green diodes on time (10 to 1000s)
Red On Time Sets red diodes on time (2 to 1000s). Note: ashing/solid
combined on time.

2D
Parallel Only
Off Panachrome+has 48 parallel beams and the option to activate
or deactivate a further 186 diagonal beams. Choose to have
parallel beams only ON or OFF.
On
Timeout/EN81-20
Off This enables/disables 2D timeout for up to 5 non-adjacent
infra-red diodes.
On
Timeout Period Beam timeout time (10 to 360s)
Cdn TMO Period Canadian timeout time setting (not enabled)
Sleep
Off
Turn sleep mode ON or OFF. Default OFF.
On
3D
3D Enable
Off Enable/disable 3D detection. Default OFF for 2D only
detectors (G2510 or G2540) and has no eect.
On
3D Mode See Section 7 for more details
On at Closing 3D activates when the doors are closing.
On at 800mm 3D activates when the doors are approx. 800mm apart.
On Always 3D always on with no 3D timeout.
On (10s) 3D always on with 10s 3D timeout.
On (20s) 3D always on with 20s 3D timeout.
Sensitivity
High
3D sensitivity settings. Choose according to installation. If false
triggering on High then choose a lower sensitivity.
Intermediate
Low
Timeout Count Counts the 3D triggers (2 to 10) and disables 3D once this count
is reached. Note: resets with a 2D trigger.
Second Relay
Copy Main Relay 2 mimics main relay (relay 1).
EN81-20 Mode
Relay 2 activates when EN81-20 conditions are not met.
This can be that a diode(s) has timed out which means the
50mm target detection is now not met, or a system fault has
developed.
Canadian Canadian timeout. If a trigger is on for the timeout period (Cdn
TMO) then the relay will activate.
Disabled Relay 2 disabled.
Audio
Beeper
Off Beeper o.
Beep On Beeper active on a trigger.
Beep Closing Beeper active when the doors are closing.and triggered
Speech
Off Speech output o.
On Speech output on.
Speech Volume Speech volume (0 to 9). Note: 0 volume is lowest setting and
not equivalent to OFF.
Speaker
Internal Enable internal speaker.
External Enable external and disable internal speaker.

Speech Language
English
Defaulted to the same as menu language.
French
German
Italian
Spanish
Japanese
Key Sounds
Off
Keypad sounds OFF/ON
On
Advanced
Top Diode
Sets which diode is the top (rst) diode in the beam pattern
(1 to 6). This can be used to deactivate top diodes if they are
triggered by the door mechanism. Note that using this may not
be in compliance with EN81 requirements.
Bottom Diode
Sets which diode is bottom (last) diode in the beam pattern (12
to 48). Note that using this may not be in compliance with EN81
requirements.
Profile
10mm G2510/G3510
43mm G2540/G2510
Display
Status Coded display of conguration and status - see below
Averages Signal levels
Version Firmware version
Access PIN Future use
Serial Number Serial number of controller
Firmware Ver. Displays the rmware version.
Detector FW Detector Firmware Version
Tx
Firmware version for each board in detector
Rx
Status Display:
The controller utilizes the LCD to show a coded status, so that common important settings can be observed at a glance.
This is also helpful for Avire service so they can get the conguration without going through menus.
The left hand side of the display shows status, the right hand side conguration
The format is as follows:
Digit Meaning
1 ‘2’ indicates 2D trigger
2‘3’ indicates 3D trigger
3If untriggered, 1 -3 indicate approximate distance in cm (max 250cm)
4‘S’ detectors are in energy saving mode
5‘T’ 1 or more diodes timed out, ‘t’ permanent trigger
6‘:’ Separator between status and cong
7‘v’ if visible mode on
8‘N’ visible normal, ‘D’ visible demo mode, ‘E’ visible external inputs, ‘T’ visible trigger

On at Closing 3D proximity detection will be activated as the doors begin to close. The system will allow up to three
consecutive triggers on the 3D (this can be changed by the Timeout Count setting up to 10 triggers).
After this, the 3D will be turned OFF leaving only the 2D detection. If there is a 2D trigger then the
Timeout Count is reset.
On at 800mm
This mode of 3D operation is similar to ON at Closing but the 3D will only become active when the
doors are closing and have reached a separation of approximately 800mm. This mode is usually for
wider doors to restrict the range of 3D detection into the landing.
On Always The 3D detection will always be active without the 3D timeout timer (see following modes).
On (10s)
In this mode the 3D detection is activated when the doors have reached their fully opened position
(max 1.2m). As long as the 3D detection zone is clear the doors will be closed normally by the door
operator. However, if someone is inside the 3D detection zone then the doors will be held open i.e.
the main relay is de-energised and a timer is started. If the timer expires the doors are allowed to close
with an intermittent beep sounding as a warning. This beep will occur regardless of the beeper setting.
If the 3D zone becomes clear then the timer is reset and the main relay is re-energised allowing the
doors to close. If there is a 2D trigger at any time, the timer will then be reset and the door operator
relay is de-energised which allows the doors to re-open. The 3D timer is set at 10 seconds internally.
On (20s) This is the same as ON (10s) but the timer is set to 20 seconds.
Ext. Inp. Open The door open and close signals can be either rising e.g. signal goes from 0V to +24VDC, or falling so
+24VDC to 0V for example. The signals are connected to terminals 13 and 14 (Door Closing) and 14 and
15 (Door Opening). Note: the inputs are not polarised.
There are two methods of using the external door inputs:
1. Nudging: when the Panachrome+is used in Normal mode and the elevator controller provides a
nudging facility, then the nudging control signal can be connected to the Panachrome+D/C (Door
Closing) input. This will ensure that when the doors close under nudging control the Panachrome+
visible diodes remain red, even if the detectors are triggered.
2. Open/Close signalling: this provides the fastest visible diode response to indicate door movement,
but if the detectors are statically mounted then these inputs can be used to activate the red/green
indications.
Ext. Inp. Close
6. Visible Diodes Modes detailed
7. 3D Modes detailed
9‘1’ 10mm prole, ‘4’ 43mm prole
10 ‘3’ if 3D enabled
11 ‘c’ 3D active on closing, ‘8’ 3d on at 800mm, ‘a’ 3D on always, ‘t’ 3D 10s timeout, ‘w’ 2D 20s timeout
12 ‘H’ for 3D high sensitivity, ‘M’ 3D intermediate sensitivity, ‘L’ 3D low sensitivity
13 ‘P’ 48 beam mode
14 ‘S’ sleep (energy saving mode) ON
15 ‘T’ timeout ON
PACG IG V02 (GB)_PA: 01/11/2017
Avire Ltd
Unit 1, The Switchback
Gardner Road
Maidenhead
Berkshire
SL6 7RJ, UK
T: 01628 540100
F: 01628 621947
E: sales.uk@avire-global.com
W: www.avire-global.com
Memco is a brand of Avire

2. 安装
1. 应把Panachrome+控制器装在轿顶稳固不易碰到的位置,避免受损。
2. 控制器应接入合适的电源和输入信号(参见以下端子指南)
3. 当光幕安装好时(参看图3),要保证光幕电缆和随行电缆(015 455)稳固的固定在门上,随行电缆正确接到门机。
4. 将发射(TX)光幕和接收(RX)光幕电缆接头接入控制器所标的插座中 (参看图4)。说明:任意一个插座都可使用,因为智能
软件可以识别插入了哪个插座。
5. 安装完毕后,用手多次开关门,检查随行电缆(015 455)移动顺畅不会挂住,否则会造成电缆接头被电梯门磨损或被电梯挂
到。(参看图1)
6. 光幕正常运行时,显示屏将短暂显示以下讯息:
注意:TX/RX后面的数字是每个光幕中PCB的数量。
如果有异,请检查所有连接。
7. 绿色和红色指示灯由控制器软件控制,但如有需要也可用外部信号指示门的移动(图表1 和 图5)。
注意:安装之前请核实各个模块之间的兼容性,以保证设备能顺利运行:
Panachrome+控制器型号G3850,设计用于配合Panachrome+ 2D 光幕 [型号G2510 & G2540]和Panachrome+ 3D光幕 [型号
G3510 & G3540] -请核实型号。
Memco Panachrome+
通用控制器
安装手册
Ref No. G850 855ML CH 第2版
Panachrome+
TX 5 RX 5
1. 连接
机盖
要接触到控制器上的连接,必须卸下保护端子的盖子。端子为快速连接无螺丝型。
右侧盖子遮盖用于连接外部扬声器和光幕插座的端子。左侧盖子用于电源、继电器和外部门信号(参看图1 和 2)。

左手盖板 右手盖板
端板
端板打开装置
安装位置
在此插入光幕延长
电缆(发射端和接
收端可以一起插入
任意一个插座)
图 1: 连接

电源、继电器和外部门信号
端子编号 功能 备注
1 接地
如果通过交流电供电85至240VAC(用于直流使用17
和18)
2 零线
3 火线
4 N/O
门机继电器1,250VAC, 24VDC电流5A5 COM
6 N/C
7 N/O 1
继电器2
8 COM 1
9 N/C 1
10 N/O 2
11 COM 2
12 N/C 2
13 D/C 门关闭输入(12 至230 AC/DC).
注意:非极化
14 D/C
15 D/O 门开启输入(12 至230 AC/DC)
注意:非极化
16 D/O
17 + 如果通过直流供电,+15至48VDC
18 - 0V
只需向上提起即可拆卸端板 。
端板释放卡槽
嵌入式按钮
端子1
图表 1
图 3: 安装
图 2: 连接

光幕和外部扬声器
RX和TX可以插入5路DIN插座,因为控制器使用智能软件来确定已连接哪个插座。
选配外部扬声器可以连接到中央2路端子排上。
3. 外部信号接线示例
关门信号和公
共端(0V)
开门信号和公
共端(0V)
oooo
13 14 15 16
关门信号和公
共端(0V)
开门信号
oooo
13 14 15 16
公共端可以在Panachrome+控
制器上连接在一起
oooo
13 14 15 16
关门接触器上
的备用触点
12 - 230VAC 或
DC电源
开门接触器上
的备用触点
公共端(0V)
图 5: 安装
图 4: 安装

4.菜单导航
Panachrome+设置可以通过使用4按钮小键盘和屏幕进行更改。
按键 功能
返回/取消
▼菜单和值减少
▲菜单和值增加
菜单项选择和确认
要进入设置菜单,请先按▼。
按▼和▲进入所需功能,然后使用 选择。一些功能有多种选择,因此使用▼和▲来查看。启用的功能采用*符号指示。
注意:显示屏的底行是启用功能或菜单项。当选择第一级菜单时,顶行显示“Panachrome+”,当访问子菜单时,显示内容将变
化。
例如:
第一级 第二级
Panachrome+
Visible Diodes
在导航菜单时,有3种类型的音调:
1. 单短高音 - 菜单导航
2. 单低音音调 - 选择不正确
3. 三个短音 - 设置更改确认
Visible Diodes
▼ Mode
光幕外形选择
控制器的配置必须符合正确的光幕宽度。不正确的选择可能会导致经常性的误触发,特别是接近关闭的时候。
对于初始安装,按住向下键直到菜单显示Quick Config(快速配置),选择此项,然后向下,直到选择正确的型号。 当选中后,
控制器将发出一串哔哔声。这也将所有的配置参数还原为出厂设置。
要更改光幕外形设置,选择高级,外形宽度,然后选择10mm或43mm。

5. 菜单导航
Language
English
语言选择
French
German
Italian
Spanish
Czech
Quick Config
G3510
产品版本快速设置器
(2 = 2D, 3 = 3D) (10 = 10mm, 40 = 43mm)
G2510
G3540
G2540
Visible Diodes
Mode
Normal 当光幕触发并且门开启/门正在打开时,绿色亮起。当门正在关闭时
红色闪烁,当门关闭时红色常亮。
External Inp. 通过开门和关门信号控制可见二极管。选择是由外部信号的上升边
缘或者下降边缘来激活这个功能(详见第6节)。
Demo 绿色和红色二极管的连续演示序列。
Trigger 当光幕触发时,可见二极管将从绿色变为红色。
Test 仅限内部使用。
Off 关闭可见二极管。
Sides
Both On
这控制将哪个光幕,TX或RX使其可见二极管开启或关闭。默认设置
为TX和RX可见二极管都开启。
TX only ON
RX only ON
Ext. Inp. Open
Rising Edge
开门信号上升边缘或下降边缘信号(详见第6章)。
Falling Edge
Ext. Inp. Close
Rising Edge
关门信号上升边缘或下降边缘信号(详见第6章)。
Falling Edge
Green On Time 设置绿色二极管开启时间(10至1000秒)
Red On Time 设置红色二极管开启时间(2至1000秒)。注意:闪烁/常亮组合开
启时间。
2D
Parallel Only
Off Panachrome+具有48束平行光束,以及可以选择激活或停用另外
186束对角光束。选择使平行光束仅仅ON或OFF。
On
Timeout/ EN81-
20
Off
这启用/禁用最多5个不相邻的红外二极管的2D timeout(超时)。
On
Timeout Period 光束超时时间(10至360秒)
Cdn TMO Period 加拿大超时时间设置(未启用)
Sleep
Off
打开或关闭睡眠模式。默认OFF关闭。
On

3D
3D Enable
Off 启用/禁用3D检测。仅2D光幕(G2510或G2540)的默认OFF,并
且不起效。
On
3D Mode 更多详细信息,请参见第7节
On at Closing 当正在关门时3D激活。
On at 800mm 当关门门距达800毫米才开启3D模式。
On Always 3D始终开启,没有3D超时。
On (10s) 3D始终开启, 3D超时10秒。
On (20s) 3D始终开启, 3D超时20秒。
Sensitivity
High
3D灵敏度设置。根据安装进行选择。如果在高灵敏度一档发现有误
触发,将灵敏度调低一档再试,直到门开关正常。
Intermediate
Low
Timeout Count 计数3D触发器(2至10),并在达到此计数后,3D功能将关闭。注
意:使用2D触发器进行复位。
Second Relay
Copy Main 继电器2模拟主继电器(继电器1)。
EN81-20 Mode
当不满足EN81-20条件时,继电器2激活。这可能是二极管已经超
时,这意味着现在不满足50mm目标检测,或者已经出现系统故
障。
Canadian 加拿大超时。如果在超时周期(Cdn TMO)里触发器开启,则继电
器将激活。
Disabled 继电器2禁用。
Audio
Beeper
Off 蜂鸣器关闭
Beep On 蜂鸣器在触发器上有效。
Beep Closing 当门关闭并且被触发时蜂鸣器被激活
Speech
Off 语音输出关闭。
On 语音输出开启。
Speech Volume 语音音量(0至9)。注意:0音量是最低设置,不等同于OFF。
Speaker
Internal 启用内部扬声器。
External 启用外部扬声器并禁用内部扬声器。
Speech Language
English
缺省语言同菜单语言
French
German
Spanish
Japanese
Key Sounds
Off 按键音 关闭/打开
On

Advanced
Top Diode
设置哪个二极管是光束模式(1至12)中的顶级(第一个)二极
管。如果它们由门机构触发,则这可用于禁用顶级二极管。请注
意,使用这项设置可能不符合EN81要求。
Bottom Diode 设置哪个二极管是光束模式(12至48)中的最末(最后一个)二极
管。请注意,使用这项设置可能不符合EN81要求。
Profile
10mm G25010/G3510
43mm G2540/G2510
Display
Status 配置和状态的编码显示 - 见以下
Averages 信号电平
Version 固件版本
Access PIN 未来使用
Serial Number 控制器序列号
Firmware Ver. 显示固件版本。
Detector FW
Tx
探测器每个电路板的软件版本
Rx
状态显示:
控制器利用LCD显示编码状态,从而可以一目了然地观察到常见的重要设置。这也有助于欧捷服务,这样他们可以在不经过菜单
的情况下获得配置。
显示屏的左侧显示状态,右侧显示配置
格式如下:
数字 含义
1‘2’表示2D触发
2‘3’ 表示3D触发
3如果未触发,则1-3表示以厘米为单位的近似距离 最大值
4‘S’探测器处于节能模式
5‘T’1个或更多个二极管超时,‘t’永久触发
6‘:’状态和配置之间的分隔符
7‘v’如果可见模式开启
8‘N’可见正常,‘D’可见演示模式,‘E’可见外部输入,‘T’可见触发
9‘1’10mm外形宽度,‘4’43mm外形宽度
10 ‘3’如果3D启用
11 ‘c’3D在关闭时激活,‘8’3d在800mm时激活,‘a’3D始终激活,‘t’3D 10秒超时,‘w’2D 20秒超
时
12 ‘H’用于3D高灵敏度,‘M’ 3D中等灵敏度,‘L’3D低灵敏度
13 ‘P’ 48光束模式
14 ‘S’睡眠(节能模式)开启
15 ‘T’超时开启

On at Closing 3D探测功能将在关门时开始。在此期间最多可以被触发3次(在Timeout Count设置中可以将其更改为触发
10次)。之后,3D功能将关闭,只剩普通光幕功能。若普通光幕功能下出现了遮挡和触发,则3D功能再次恢
复。
On at 800mm 这种3D模式类似于”关门有效”模式,只是3D探测功能会在关门门距达800毫米(2’8’’)才开启。此
模式通常用于比较宽的门,使3D探测在有限的空间内进行。
On Always 在没有3D超时定时器的情况下,3D检测将始终处于启用状态(见以下模式)。
On (10s)
在这种模式下,3D探测会在最大开门距(最大1.2米)时候开始。只要3D探测范围内没有物体,门机就会正
常关门。如果3D探测区域发现有人,门就会保持开启状态,就是门机上的继电器一直处于释放状态来开门,
同时控制器计时开始。如果计时时间到了,控制器允许关门同时发出警告音,无论”Tone”开关放在什么状
态警告音都会有。3D探测区域物体消失,门机继电器吸合,开始关门。任何时候2D光幕出现遮挡,计时器重
置,门机继电器释放,重新开门。控制器内部设定3D超时为10秒。
On (20s) T与On (10秒)的情况类似,只是计时器时间内部设定为20秒。
Ext. Inp. Open 开门和关门信号可以上升,例如 信号从0V变为+ 24VDC,或下降,例如从+ 24VDC下降至0V。信号连接到端
子13和14(关门)以及14和15(开门)。 注意:输入非极化。
有两种使用外部门输入的方法:
1. 微移:当Panachrome+在正常模式下使用并且电梯控制器提供微移设置时,微移控制信号可以连接到
Panachrome+ D / C(关门)输入。 这将确保在微移控制下关门时,Panachrome+可见二极管保持红色,
即使光幕被触发。
2.开门/关门信号:这提供了最快的可见二极管响应来指示门的移动,但如果光幕静态安装,则这些输入可用
于激活红色/绿色指示。
Ext. Inp. Close
6. 可见二极管模式详细介绍
7. 3D工作模式详细介绍
Avire Ltd
4th oor,
G Building, 1999 -2059 Du Hui Road
Shanghai 201108, China
T: +21 64953748
F: +21 64859264
E: sales.cn@avire-global.com
W: www.memco-global.com
W: www.avire-global.com
Memco is a brand of Avire
PACG IG V02 (CH)_PA: 16/11/2017

2. Instalace
1. Abyste předešli poškození, zajistěte ovladač Panachrome+ve vhodné poloze na horní ploše kabiny.
2. Připojte ovladač ke správnému přívodnímu napětí a vstupům (viz Fig 3 níže).
3. Až budou instalovány detektory (viz průvodce instalací detektorů), bude důležité zajistit, aby kabely detektorů a
posuvné kabely (015 455) byly řádně zajištěny k dveřím a aby posuvné kabely byly řádně napojeny na ovladač.
4. Kabely vysílače (TX) a přijímače (RX) připojte do zásuvek ovladače. Poznámka: použít lze kteroukoli zásuvku, protože
inteligentní software rozpozná, který detektor je připojen (viz Fig 4).
5. Po dokončení opatrně otevřete a zavřete rukou dveře pro kontrolu, zda má posuvný kabel (015 455) hladký a volný
pohyb a zda při pohybu za normálního provozu o nic nezadrhává. V případě, že tomu tak není, existuje riziko poškození
kabelů dveřmi výtahu nebo jejich zachycení při pohyby výtahu. Viz obrázek 1.
6. Při správném provozu zobrazí displej následující:
Poznámka: číslo následující po TX/RX je počet PCB jednotlivých detektorech.
Bude-li odlišné, zkontrolujte prosím všechna připojení.
7. Zelený a červenou kontrolku bude ovládat software, avšak v případě potřeby lze použít i externí signalizaci (viz níže
uvedený průvodce ke koncovkám).
Poznámka: Před instalací se prosím ujistěte, zda jsou jednotky kompatibilní, aby byl zajištěn
spolehlivý a bezproblémový provoz:
Ovladač Panachrome+G3850 je navržen pro provoz s detektory Panachrome+2D [G2510 a G2540] i Panachrome+3D
[G3510 a G3540]. Zkontrolujte, zda máte správné výrobky.
Univerzální ovladač
Memco Panachrome+
Průvodce instalací
Ref. č. G850, 855ML CZ, verze 2
Panachrome+
TX 5 RX 5
1. Připojení
Kryty
Pro přístup k připojením na ovladači je potřeba odstranit kryty chránící koncovky. Koncovky jsou rychlospojovacího
nešroubového typu.
Kryt na pravé straně obsahuje koncovky k připojení zásuvek externího reproduktoru a detektoru. Kryt na levé straně je
pro napájení, relé a externí dveřní signály (viz Fig 1 a 2).

Kryt na levé straně Kryt na pravé straně
Čelní stěna
Spona uvolňování čelní stěny
Uchycení do polohy
Sem připojte
prodlužovací
kabely detektoru
(přijímač a
vysílač lze
připojit do
kterékoli z obou
zásuvek)
Fig 1: Připojení
Table of contents
Languages:
Popular Controllers manuals by other brands

Bosch
Bosch BAT 251 Original instructions

LS Industrial Systems
LS Industrial Systems SV-iS7 Series troubleshooting manual

Bosch
Bosch FHP560 Applications manual

Danfoss
Danfoss VLT HVAC Basic Drive FC 101 quick guide

Johnson Controls
Johnson Controls T-5800 Series Installation and Calibration

Roth
Roth Touchline SL manual