Metalumen S6 User manual

570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 1
Specications and design subject to change without notice.
NOTE: The following instructions provide general guidelines for product installation. These
instructions apply to the S6 sized xtures. For additional information consult the applicable
electrical codes or contact factory directly for support before attempting anything with
uncertainty.
CAUTION: Do not assemble xture runs on oor.
WARNING: Risk of re and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing
or servicing this product.
GENERAL SAFETY INSTRUCTIONS:
1. Read all instructions prior to installing this xture.
2. This product must be installed in accordance with the applicable installation code by a person familiar
with theconstruction and operation of the product and the hazards involved.
3. All wiring must be performed by a qualied electrician in accordance with national and local building
and electrical codes.
4. This xture must be suitably grounded for your protection against shock hazards and to assure proper
operation.
5. Make sure that the power source conforms to the requirements of this xture.
6. This product has accessible output terminals. Based on Canadian Electrical Code for class 2 circuits,
this productrequires installation in Restricted Access Area, so that no live parts are accessible to
unauthorized persons.
INSTALLATION
INSTRUCTIONS
RAIL 6
S6 Pendant, Direct Integral Driver

Specications and design subject to change without notice.
570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 2
INSTALLATION INSTRUCTIONS S6 Pendant, Direct Integral Driver RAIL 6
PARTS LIST
A. Luminaire
B. Wire Entry Canopy
C. Non-Wire Entry Canopy
D. Aircraft Cable
E. Gripper
TOP VIEW BOTTOM VIEW
WIRING DIAGRAM
INTEGRAL DRIVER TO LINE VOLTAGE

Specications and design subject to change without notice.
570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 3
INSTALLATION INSTRUCTIONS S6 Pendant, Direct Integral Driver RAIL 6
STEP-BY-STEP INSTALLATION INSTRUCTIONS
STEP 1. Remove xture and hanger kit
packaging; note power cord coming out at the
top of the luminaire (one end only)
STEP 2. Secure Hex-Box (supplied by others) to
a structure of suitable strength to support the
xture.
STEP 3. Secure hanger bracket to the hex box. STEP 4. Connect gripper to xture. Adjust height
of xture by pushing and pulling cable through
gripper.
STEP 5. Wire xture to line voltage as per wiring
diagram. For Grid, cable is fed through the
hole in the provided wire entry corner piece.
STEP 6. Secure canopy to ceiling.

Specications and design subject to change without notice.
570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 4
INSTALLATION INSTRUCTIONS S6 Pendant, Direct Integral Driver RAIL 6
STEP-BY-STEP INSTALLATION INSTRUCTIONS
STEP 7. Example of completed xture.
STEP 8. For continuous runs, install Start xture
rst. (As per Steps 1 to 7)
STEP 9. Remove the lens from the mid/end unit.
STEP 10. Unscrew the reector assembly inside
the mid/end unit.
STEP 11. Remove reector assembly from mid/
end unit.

Specications and design subject to change without notice.
570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 5
INSTALLATION INSTRUCTIONS S6 Pendant, Direct Integral Driver RAIL 6
STEP-BY-STEP INSTALLATION INSTRUCTIONS
STEP 12. Align mid/end xture and slide it into
place. Secure with screws. Reinstall reector
assembly and lens in mid/end. Perform
necessary wiring between xtures.
STEP 13. Example of completed continuous run.
STEP 14. For corners, remove the lens and
reector pairs from the corner unit (see steps
9-11). Attach the corner to the preceding unit
joiner brackets using 3 screws.
STEP 15. Attach the next mid/end unit to the
corner unit (see steps 9-12). Connect wires
between xtures as per the wiring diagram.
Reinstall the reector and lens in corner.

Specications and design subject to change without notice.
570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 6
INSTALLATION INSTRUCTIONS S6 Pendant, Direct Integral Driver RAIL 6
STEP-BY-STEP INSTALLATION INSTRUCTIONS
STEP 16. Cut o extra hangers at the corner joint
from adjacent linear units. Keep cuts clean and
close to xture body. Hang the assembly from
the corner unit hangers (see steps 2-6).
STEP 17. Example of completed grid.

Specications and design subject to change without notice.
570 Southgate Drive, Guelph, Ontario N1G 4P6
Mailing Address: P.O. Box 1779
Guelph, Ontario N1H 6Z9
T 1.800.621.6785 | T 519.822.4381 | F 519.822.4589
www.metalumen.com IS-S6-P rev.01
PAGE 7
INSTALLATION INSTRUCTIONS S6 Pendant, Direct Integral Driver RAIL 6
MAINTENANCE STEPS
Required Tools
Plastic / Latex
Gloves
Screwdriver
Important: Use clean gloves to avoid adding oil/dirt to reector surface. Avoid scratching reector
surface by using installation tools with soft plastic rounded edges.
STEP 1. For LED board maintenance, remove the
lens from the bottom of the unit.
STEP 2. For driver maintenance, rst unscrew the
reector assembly.
STEP 3. Remove reector assembly from unit. STEP 4. Remove and service driver as required.
Table of contents