Metra Electronics ELS User manual

Locker Controller ELS & ELS SELECT Technical Manual

Page 2
Locker Controller ELS & ELS SELECT Technical Manual
Table of contents
Locker Controller ELS & ELS SELECT Technical Manual........................................................................... 4
Product description............................................................................................................................. 4
Basic Parts ........................................................................................................................................... 5
Locker Controller PCB with two extension modules and connecting PCB ..................................... 5
Display............................................................................................................................................. 5
Emergency Open Push-button (optional)....................................................................................... 6
Coin acceptor (optional) ................................................................................................................. 6
Fingerprint module (optional) ........................................................................................................ 6
Connections ........................................................................................................................................ 6
Connecting Locker Extension Modules........................................................................................... 7
Locker Extension Module setting ................................................................................................... 8
Connecting Electronic Locks ........................................................................................................... 8
Display connection.......................................................................................................................... 9
Power supply connection (Locker Controller without distribution board) .................................. 10
Power supply connection (Locker Controller with distribution board)........................................ 10
Metra NET Network connection (Locker Controller without distribution board)........................ 11
Metra NET Network connection (Locker Controller with distribution board) ............................. 12
Coin Acceptor connection ............................................................................................................ 13
External emergency open pushbutton connection (optional) ..................................................... 13
DIP switch settings ............................................................................................................................ 14
Network address........................................................................................................................... 15
Operating modes .......................................................................................................................... 16
Power - on......................................................................................................................................... 17
Signalization ...................................................................................................................................... 17
Power-on ...................................................................................................................................... 17
Operation...................................................................................................................................... 18
Network Communication ............................................................................................................. 18
Actions and operating parameters ................................................................................................... 19
Setting Operational parameters –via Metra NET Network.............................................................. 20
Setting Operational parameters –by Display’s keypad.................................................................... 21
Setup mode activation.................................................................................................................. 21
Navigating thru menus with 4 key keypad ................................................................................... 21
Navigating thru menus with 12 key keypad ................................................................................. 21

Page 3
Locker Controller ELS & ELS SELECT Technical Manual
Initiating actions and setting operating parameters .................................................................... 22
Emergency Open procedure ............................................................................................................. 31
Internal Emergency open pushbutton.......................................................................................... 31
External Emergency open pushbutton ......................................................................................... 31
Test mode of operation .................................................................................................................... 32
Test mode activation .................................................................................................................... 32
Testing electronic locks installation.............................................................................................. 33
Closing Lockers for transportation ............................................................................................... 34
Testing Emergency open pushbutton........................................................................................... 35
Testing Coin acceptor ................................................................................................................... 36
Erasing operating parameters ...................................................................................................... 37
Warning signalization........................................................................................................................ 37
Alarm signalization............................................................................................................................ 37
Checking of locker Alarm functionality......................................................................................... 38
Expired/Blocked signalization ........................................................................................................... 38
Remote opening of single locker signalization................................................................................. 38
Functional Test.................................................................................................................................. 38
Checking locker wiring order (ELS Systems only) ......................................................................... 39
Locking / Unlocking of All Lockers ................................................................................................ 39
Device replacement .......................................................................................................................... 39
Maintenance ..................................................................................................................................... 40
Troubleshooting Guide ..................................................................................................................... 40
Technical data ................................................................................................................................... 40
Appendix ........................................................................................................................................... 41

Page 4
Locker Controller ELS & ELS SELECT Technical Manual
Locker Controller ELS & ELS SELECT Technical Manual
Manufacturer:
Metra inženiring d.o.o.
IOC Trzin
Špruha 19
SI-1236 Trzin, Slovenia
phone:
fax:
web:
+386 1 56 10 740
+386 1 56 10 744
www.metra.si
System:
Metra ELS & ELS SELECT–Electronic Locking Systems
Product Group:
Locker Controller
Types:
LC16AELKP, LC16AESKP, LC16ELKP, LC16ESKP, LC24ELKP, LC24ESKP, LC32ELKP, LC32ESKP (Keypad)
LC16AELIS, LC16AESIS, LC16ELIS, LC16ESIS, LC24ELIS, LC24ESIS, LC32ELIS, LC32ESIS (ISO 15693, ISO14443A/B)
LC16AELLF, LC16AESLF, LC16ELLF, LC16ESLF, LC24ELLF, LC24ESLF, LC32ELLF, LC32ESLF (LF Multitag)
LC16AELMF, LC16AESMF, LC16ELMF, LC16ESMF, LC24ELMF, LC24ESMF, LC32ELMF, LC32ESMF (Mifare)
LC16AELSD, LC16AESSD, LC16ELSD, LC16ESSD, LC24ELSD, LC24ESSD, LC32ELSD, LC32ESSD (Skidata)
LC08 (Locker Controller Extension Module)
Year of Construction:
2008-2011
Declaration of Conformity:
The Metra ELS & ELS SELECT products have been developed, designed
and manufactured in accordance with the EU directive for
Electromagnetic Compatibility (2004/108/EC).
Locker Controller ELS & ELS SELECT Technical Manual [rev.0-030811]
2011 Metra inženiring d.o.o.
All Rights reserved.
No part of this manual may be reproduced in any form or by any means without prior written permission of Metra inženiring d.o.o.
The contents of this manual are subject to change without notice.
All efforts have been made to ensure the accuracy of the contents of this manual, however, should any errors be detected, Metra inženiring would greatly appreciate being informed of
them. Metra inženiring d.o.o. can assume no responsibility for any errors in this manual.
Product description
Metra Locker Controller is used in different Metra Electronic Locking Systems. Device drives and
monitors Metra Electronic Locks. Up to 16 locks can be connected directly to the unit, with the
possibility to add up to two Extension Modules for 8 additional Electronic Locks each. This enables
configurations for up to 16, 24 or 32 locks, which makes the controller adoptable to many locker
layout configurations. As user interface different system specific Metra user interface devices (e.g.
Display RFID/Keypad/Combo/Touch, Reader Terminal, Reader Terminal Basic, etc.) can be used.

Page 5
Locker Controller ELS & ELS SELECT Technical Manual
Locker Controller also supports emergency and security features. A pushbutton for emergency
opening of all Lockers connected to the Locker Controller (and belonging extension modules) is fitted
on the main electronics board and also an external emergency pushbutton can be connected. In case
of attempt of break-in an Alarm message is distributed over Metra NET Network to Metra user
interface devices and over Metra Network Controller to LAN / WAN and Metra software.
Different (system specific) enhancing accessories are available: Euro deposit pad to limit locker
misuse, coin acceptor to generate revenue from locker use, fingerprint module to lock / unlock
lockers simply by placing the finger as an addition to Keypad and/or RFID media reader on user
interface device.
For easier installation on site different configurations of controller & extension module(s) on
mounting plates are supplied.
Basic Parts
Locker Controller PCB with two extension modules and connecting PCB
Display
Display Combo
Display RFID
Display Keypad
Metra Display RFID is a user interface for Metra ELS systems, while
Metra Display Combo and Keypad are a user interfaces for Metra
ELS and Metra ELS SELECT systems.
Display Combo: Read RFID tickets as locker keys. Twelve key
washable keypad is integrated to enable additional user
interaction (PIN, locker number, etc.) and can be used for locking /
unlocking instead of RFID media.
Display RFID: Reads RFID tickets as locker keys.
Display Keypad: Integrated 12 key washable keypad to enable
user interaction (PIN, locker number, etc.).
Each model shows the locker number on a four digit LED display.
They also perform audio signalization and show an alarm message
if an attempt of break-in is detected on a Metra Electric Lock
connected to a Metra Locker Controller.
Locker Controller’s operating parameters are set up through
integrated 4 key system keypad (Display RFID) or through 12 key
keypad (Display Combo and Keypad) and stored in Locker
Controller’s internal battery powered memory. To simplify setup
of Locker Controller and manage master keys and master/setup
codes also Metra software can be used.

Page 6
Locker Controller ELS & ELS SELECT Technical Manual
Emergency Open Push-button (optional)
Emergency Open Push-button is used to initiate Emergency Open procedure
for all Electronic Locks connected to Locker Controller.
Coin acceptor (optional)
Locker Controller can be configured to ask for payment when locking the locker
door. In that case Coin Acceptor is mounted near the Display.
Fingerprint module (optional)
Fingerprint module allows users to lock/unlock the locker by presenting the
finger to sensor. It offers higher comfort for users as they don't need to
remember PIN code or carry around the RFID media. When fingerprint module
is connected to Locker Controller each user can freely choose whether he/she
will lock the locker using fingerprint/PIN code/RFID media.
Connections

Page 7
Locker Controller ELS & ELS SELECT Technical Manual
#
description
#
description
1
Electronic Lock 1
27
Electronic Lock 27
2
Electronic Lock 2
28
Electronic Lock 28
3
Electronic Lock 3
29
Electronic Lock 29
4
Electronic Lock 4
30
Electronic Lock 30
5
Electronic Lock 5
31
Electronic Lock 31
6
Electronic Lock 6
32
Electronic Lock 32
7
Electronic Lock 7
33
Local CAN*
8
Electronic Lock 8
34
Local CAN*
9
Electronic Lock 9
35
BDM Loader
10
Electronic Lock 10
36
Local CAN**
11
Electronic Lock 11
37
Local CAN**
12
Electronic Lock 12
38
BDM Loader
13
Electronic Lock 13
39
COM (Not used)
14
Electronic Lock 14
40
Local CAN***
15
Electronic Lock 15
41
Local CAN***
16
Electronic Lock 16
42
Metra NET Network
17
Electronic Lock 17
43
Power****
18
Electronic Lock 18
44
Power****
19
Electronic Lock 19
45
Emergency open pushbutton
20
Electronic Lock 20
46
Coin acceptor
21
Electronic Lock 21
47
Reader (Not used)
22
Electronic Lock 22
48
Fingerprint module
23
Electronic Lock 23
49
Display
24
Electronic Lock 24
50
I2C (Not used)
25
Electronic Lock 25
51
BDM Loader
26
Electronic Lock 26
52
I2C (Not used)
*NOTE: Local CAN connectors and are internally parallel connected.
**NOTE: Local CAN connectors and are internally parallel connected.
***NOTE: Local CAN connectors and are internally parallel connected.
****NOTE: 12V DC Power connectors and are internally parallel connected.
Connecting Locker Extension Modules
When Locker Controller without mounting plate is used connect up to two Extension modules by 6
wire flat cable. There are two equivalent connectors on the main electronics board (LC16A) use the
one which suits your connection best.

Page 8
Locker Controller ELS & ELS SELECT Technical Manual
When Locker Controller is ordered with mounting plate Extension Modules (LC24_* and LC32_*) are
already connected.
Locker Extension Module setting
The first Locker Extension Module DIP switch (indexes 17-24) and second Locker Extension Module
DIP switch (indexes 25-32) must be set as follows:
Connecting Electronic Locks
Connect Electronic Locks using 6 wire flat cables.
Maximum length of each cable is 20 meters.
Cables from Electronic Locks with lower locker numbers must be connected to lower index
connector. Locker number is increasing from left to right (blue arrows)!
Mind ascending order when numerating lockers. Gaps between numbers are allowed.

Page 9
Locker Controller ELS & ELS SELECT Technical Manual
EXAMPLE: Most left connector (index 1) is locker number 161, most right connector (index 32) is
locker number 192.
Display connection
Plug the 10 wire flat cable from the Display to the connector as shown in the schematic. See also
“Display – Technical Manual”.

Page 10
Locker Controller ELS & ELS SELECT Technical Manual
Power supply connection (Locker Controller without distribution board)
Regulated 12 VDC power supply is required for proper operation. Connect as many units as possible
to a single power supply unit. Consult the Technical Specifications section of this document for
current consumption.
There are two internally connected power connectors on the board. You can use one as “Power IN”
and the other as “Power OUT” connector.
Connect 12V DC regulated power supply to designated terminals. The terminals are marked as +12V
for positive connection and GND for ground connection.
WARNING
Mind the polarity! Wrong polarity could result in irreparable damage to the device.
Respect power requirements data! Using unsuitable power supply could result in damage to the
power supply and to the device.
Power supply connection (Locker Controller with distribution board)
Regulated 12 VDC power supply is required for proper operation. Connect as many units as possible
to a single power supply unit. Consult the Technical Specifications section of this document for
current consumption.
Connect 12V DC regulated power supply to designated terminals. The terminals are marked as +12V
for positive connection and GND for ground connection.
WARNING
Mind the polarity! Wrong polarity could result in irreparable damage to the device.
Respect power requirements data! Using unsuitable power supply could result in damage to the
power supply and to the device.

Page 11
Locker Controller ELS & ELS SELECT Technical Manual
Metra NET Network connection (Locker Controller without distribution board)
The Metra NET Network connection provides for operational functionality of the Locker Controller.
Different devices in parallel can be connected to the Metra Network Controller by a single unshielded
twisted pair (UTP) cable. Total length of the twisted pair cable is limited to 1 km. One Network Line
Terminator must be connected at the far end of the network cable. See also “Metra NET Network –
Installation Manual” for different wiring schemes.
Connect the twisted pair network cable to designated terminals. The terminals are marked as CANLO
for network low signal and CANHI for network high signal.
NOTE
Mind the polarity of the network connection!

Page 12
Locker Controller ELS & ELS SELECT Technical Manual
Metra NET Network connection (Locker Controller with distribution board)
Connect the twisted pair network cable to designated terminals. The terminals are marked as CANL
for network low signal and CANH for network high signal.
NOTE
Mind the polarity of the network connection!

Page 13
Locker Controller ELS & ELS SELECT Technical Manual
Coin Acceptor connection
Connect the Coin acceptor to designated terminals as shown in the schematic.
External emergency open pushbutton connection (optional)
Connect the blue and blue/white wires of the UTP cable from the Emergency open pushbutton to
designated terminals as shown in the schematic.

Page 14
Locker Controller ELS & ELS SELECT Technical Manual
DIP switch settings
#
description
1
Emergency open pushbutton
2
Parameters request button
3
Network Address DIP switch
4
Operating Mode DIP Switch
By changing the Operating Mode DIP Switch pins positions, different operating modes and
parameters can be set and by changing the Network Address DIP Switch pins positions, different
network address can be set. To change between different pins positions, use a small flat headed
screwdriver or similar object to push DIP switch pins to desired position.
After each settings change or after device’s first installation power off and back on the device (for the
new settings to take effect) and obtain operating parameters if the device is connected to Metra NET
Network controlled by Metra Network Controller and Metra SW.
Operating parameters are obtained through the Metra NET Network. The server must be set up and
running for that purpose. To obtain operating parameters, press the PARAMETERS REQUEST
button.
NOTE
Before changing between Normal/Test or ELS/ELS SELECT mode of operation all lockers must be
unlocked via external or internal emergency open pushbutton .
NOTE
Network based functionality will be present only if the server is running and the Locker Controller has
been properly configured.

Page 15
Locker Controller ELS & ELS SELECT Technical Manual
Network address
After installation is complete, the device’s network address must be set by changing the Network
Address DIP Switch pins positions.
NOTE
Each Metra device must have different address setting.
Look up the code for desired network address in the coding table. Set switch #1 to indicated position,
where:
0 (switch down) = No offset in network address.
1 (switch up) = “+600” offset in network address.
Set switches #2 through #8 to indicated positions, where:
0 indicates the corresponding switch is in OFF position (switch down)
1 indicates the corresponding switch is in ON position (switch up)
Coding table:
switch positions
address
switch positions
address
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
0/1
0
0
0
0
0
0
0
1/601
0/1
0
1
1
0
0
1
0
51/651
0/1
0
0
0
0
0
0
1
2/602
0/1
0
1
1
0
0
1
1
52/652
0/1
0
0
0
0
0
1
0
3/603
0/1
0
1
1
0
1
0
0
53/653
0/1
0
0
0
0
0
1
1
4/604
0/1
0
1
1
0
1
0
1
54/654
0/1
0
0
0
0
1
0
0
5/605
0/1
0
1
1
0
1
1
0
55/655
0/1
0
0
0
0
1
0
1
6/606
0/1
0
1
1
0
1
1
1
56/656
0/1
0
0
0
0
1
1
0
7/607
0/1
0
1
1
1
0
0
0
57/657
0/1
0
0
0
0
1
1
1
8/608
0/1
0
1
1
1
0
0
1
58/658
0/1
0
0
0
1
0
0
0
9/609
0/1
0
1
1
1
0
1
0
59/659
0/1
0
0
0
1
0
0
1
10/610
0/1
0
1
1
1
0
1
1
60/660
0/1
0
0
0
1
0
1
0
11/611
0/1
0
1
1
1
1
0
0
61/661
0/1
0
0
0
1
0
1
1
12/612
0/1
0
1
1
1
1
0
1
62/662
0/1
0
0
0
1
1
0
0
13/613
0/1
0
1
1
1
1
1
0
63/663
0/1
0
0
0
1
1
0
1
14/614
0/1
0
1
1
1
1
1
1
64/664
0/1
0
0
0
1
1
1
0
15/615
0/1
1
0
0
0
0
0
0
65/665
0/1
0
0
0
1
1
1
1
16/616
0/1
1
0
0
0
0
0
1
66/666
0/1
0
0
1
0
0
0
0
17/617
0/1
1
0
0
0
0
1
0
67/667
0/1
0
0
1
0
0
0
1
18/618
0/1
1
0
0
0
0
1
1
68/668
0/1
0
0
1
0
0
1
0
19/619
0/1
1
0
0
0
1
0
0
69/669
0/1
0
0
1
0
0
1
1
20/620
0/1
1
0
0
0
1
0
1
70/670
0/1
0
0
1
0
1
0
0
21/621
0/1
1
0
0
0
1
1
0
71/671
0/1
0
0
1
0
1
0
1
22/622
0/1
1
0
0
0
1
1
1
72/672
0/1
0
0
1
0
1
1
0
23/623
0/1
1
0
0
1
0
0
0
73/673
0/1
0
0
1
0
1
1
1
24/624
0/1
1
0
0
1
0
0
1
74/674
0/1
0
0
1
1
0
0
0
25/625
0/1
1
0
0
1
0
1
0
75/675
0/1
0
0
1
1
0
0
1
26/626
0/1
1
0
0
1
0
1
1
76/676
0/1
0
0
1
1
0
1
0
27/627
0/1
1
0
0
1
1
0
0
77/677
0/1
0
0
1
1
0
1
1
28/628
0/1
1
0
0
1
1
0
1
78/678
0/1
0
0
1
1
1
0
0
29/629
0/1
1
0
0
1
1
1
0
79/679
0/1
0
0
1
1
1
0
1
30/630
0/1
1
0
0
1
1
1
1
80/680
0/1
0
0
1
1
1
1
0
31/631
0/1
1
0
1
0
0
0
0
81/681

Page 16
Locker Controller ELS & ELS SELECT Technical Manual
0/1
0
0
1
1
1
1
1
32/632
0/1
1
0
1
0
0
0
1
82/682
0/1
0
1
0
0
0
0
0
33/633
0/1
1
0
1
0
0
1
0
83/683
0/1
0
1
0
0
0
0
1
34/634
0/1
1
0
1
0
0
1
1
84/684
0/1
0
1
0
0
0
1
0
35/635
0/1
1
0
1
0
1
0
0
85/685
0/1
0
1
0
0
0
1
1
36/636
0/1
1
0
1
0
1
0
1
86/686
0/1
0
1
0
0
1
0
0
37/637
0/1
1
0
1
0
1
1
0
87/687
0/1
0
1
0
0
1
0
1
38/638
0/1
1
0
1
0
1
1
1
88/688
0/1
0
1
0
0
1
1
0
39/639
0/1
1
0
1
1
0
0
0
89/689
0/1
0
1
0
0
1
1
1
40/640
0/1
1
0
1
1
0
0
1
90/690
0/1
0
1
0
1
0
0
0
41/641
0/1
1
0
1
1
0
1
0
91/691
0/1
0
1
0
1
0
0
1
42/642
0/1
1
0
1
1
0
1
1
92/692
0/1
0
1
0
1
0
1
0
43/643
0/1
1
0
1
1
1
0
0
93/693
0/1
0
1
0
1
0
1
1
44/644
0/1
1
0
1
1
1
0
1
94/694
0/1
0
1
0
1
1
0
0
45/645
0/1
1
0
1
1
1
1
0
95/695
0/1
0
1
0
1
1
0
1
46/646
0/1
1
0
1
1
1
1
1
96/696
0/1
0
1
0
1
1
1
0
47/647
0/1
1
1
0
0
0
0
0
97/697
0/1
0
1
0
1
1
1
1
48/648
0/1
1
1
0
0
0
0
1
98/698
0/1
0
1
1
0
0
0
0
49/649
0/1
1
1
0
0
0
1
0
99/699
0/1
0
1
1
0
0
0
1
50/650
0/1
Operating modes
Device’s operating mode and parameters are set by changing the Operating Mode DIP Switch
pins positions.
Set switches #1 through #8 to indicated positions, where:
OFF = switch down
ON = switch up
NOTE
Before changing between Normal/Test (switch 7) or ELS/ELS SELECT (switch 8) mode of operation all
lockers must be unlocked via external or internal emergency open pushbutton .
switch
positions
parameter
setting
1
Operating
mode
OFF: Normal operating mode
ON: Setup mode of operation
2
Keypad type
OFF: 4 key keypad (Display RFID)
ON: 12 key keypad (Display Combo & Display Keypad)
3
Fingerprint
module
OFF: Fingerprint module in NOT connected
ON: Fingerprint module is connected
4
Reader
OFF: RFID media reader is not present in the Display (Display Keypad)
ON: RFID media reader is present in the Display (Display Combo & Display RFID)
5
-
Not used; Must be set to OFF.
6
Special Keys
OFF:RFID media is accepted as user key (Display Combo & Display RFID)
ON: Only special keys are accepted (Display Combo & Display RFID)
7
TEST mode
OFF: Normal operating mode
ON: Test mode of operation
8
System
OFF: ELS
ON: ELS SELECT

Page 17
Locker Controller ELS & ELS SELECT Technical Manual
Power - on
After the device is powered on, its network address (number from 1 to 99 or from 600 to 699) is
shown on Display for a few seconds. This feature is intended for maintenance personnel.
NOTE: If payment is turned ON, current Saldo is displayed after the network address.
Signalization
Power-on
When power is applied the following LEDs are on:
Yellow LED on Locker Controller (12VDC present)
Green LED on Locker Controller (5VDC regulated on board active)
Yellow LED on Extension Module(s) (12VDC present)
Green LED on Extension Module(s) (5VDC present)
Green LED on distribution board (12VDC present)

Page 18
Locker Controller ELS & ELS SELECT Technical Manual
Operation
Each Locker Controller and Locker Extension Module has a blinking green LED operating indicator. All
these signals are under software control indicating that the device is running.
Network Communication
Network communication (Metra NET) is signalled on the Locker Controller by four LEDs:
Left Green LED is on when the Locker Controller is receiving data packets from Extension
Module(s).
Left Red LED is on when the Locker Controller is transmitting data packets to Extension
Module(s).
Right Green LED is on when the Locker Controller is receiving data packets from Metra NET
Network.

Page 19
Locker Controller ELS & ELS SELECT Technical Manual
Right Red LED is on when the Locker Controller is transmitting data packets to Metra NET
Network.
Actions and operating parameters
NOTE
Some operating parameters are system dependant and may not be available in your system.
For detailed actions and parameters descriptions see paragraph “Setting Operational parameters –
by Display’s keypad”.
action / parameter
System
default value
short description / values
dEFP
Default
parameters
ELS
ELS SELECT
-
Resets all parameters to factory default values.
nLOC
Number of
Lockers
ELS
ELS SELECT
32
Number of connected lockers.
Can be set to 1, 2, 3,...32.
SLOC
Starting locker
number
ELS
ELS SELECT
1
Number of first connected locker.
Can be set to 1, 2, 3,...7999.
CodE
Master Code*
ELS
ELS SELECT
-
Has 5 sub-parameters: up to 5 master codes can
be stored in.
SCod
Setting Code*
ELS
ELS SELECT
-
Has 5 sub-parameters: up to 5 setup codes can be
stored in.
Add
Add Master Key*
ELS
ELS SELECT
-
Up to 5 Master Cards can be stored in.
ErAS
Erase all special
keys and PIN
codes*
ELS
ELS SELECT
-
Erases all Master/Setup Codes and Master keys.
Aud
Audio Signal
ELS
ELS SELECT
On
Can be activated (On) or silent (OFF).
En-A
Multiple locking
ELS
OFF
Can be enabled (On) or disabled (OFF).
GrUP
PIN code for
multiple locking
ELS
8000
Visible only if multiple locking is enabled (On).
Can be set to: 8000 to 9999.
EOPn
Emergency
opening
ELS
ELS SELECT
OFF
Can be enabled (On) or disabled (OFF).
AOPn
Auto opening
ELS
OFF
Can be set to: OFF (0), 1, 2, 3,...9999.
USr
User Waiting
time
ELS
ELS SELECT
5
Can be set to 1, 2, 3,...8 seconds.
USI
User Waiting
time increment
ELS
2
Can be set to 1, 2, 3 or 4 seconds.
PinL
Minimal PIN
Length
ELS
ELS SELECT
1
Can be set to 1, 2, 3, 4 or 5.
PinC
Pin/Code
Request display
ELS
ELS SELECT
Pin
Can be set to “Pin” or “COdE”.
LEu
Locker level
ELS
OFF
Can be set to OFF, 1, 2, 3 or 4.
LAC
Locker active
time
ELS SELECT
30
Can be set to 30, 31, 32,...240 seconds
dISP
Occupied Locker
signalisation
ELS
OFF
Can be enabled (On) or disabled (OFF).

Page 20
Locker Controller ELS & ELS SELECT Technical Manual
LIS
White List
ELS
OFF
Can be enabled (On) or disabled (OFF).
PAY
Payment
ELS
ELS SELECT
OFF
Can be set to OFF, On, Sign or bLOC.
P Co
Coin Value**
ELS
ELS SELECT
1.00
Can be set to 0.10, 0.20, 0.25, 0.50, 1.00, 2.00 or
5.00.
P dU
Tenancy
Duration**
ELS
ELS SELECT
8 h
Can be set to OFF, 0 h, 1 h, 2 h,...24 h.
P LI
Payment Limit**
ELS
ELS SELECT
1
Visible only if Tenancy duration is not set to “OFF”
or “0”.
Can be set to 1, 2, 3,...31.
P dS
Currency**
ELS
ELS SELECT
Euro
Can be set to “Euro”, “Coin”, “GbP”, “PAY”, “USd”
or “CHF”.
L dU
Locking
duration***
ELS
8 h
Can be set to 1 h, 2 h, 3h,...24 h.
SALd
Display Saldo
ELS
ELS SELECT
-
Displays sum of all inserted coins.
SALE
Erase Saldo
ELS
ELS SELECT
-
Resets coin counter.
*Not avaliable if “Special Keys Mode” is set to “On-line” in Metra ELS/LCC software.
**Avaliable only if payment parameter is set to “On”.
***Avaliable only if payment parameter is set to “Sign”or “bLOC”.
Setting Operational parameters –via Metra NET Network
Metra Network Controller must be connected to Metra NET Network
Metra server must be running and all hardware added in Metra ELS/ELS NET/LCC NET software.
Each Locker Controller must have set its unique Metra NET Network address –ID.
OPTION 1 (downloading parameters to single divice at a time):
By pressing the PARAMETERS REQUEST button on the Locker Controller you trigger the request
for operating parameters.
Operating parameters are downloaded to the Locker Controller.
Check if correct operating parameters were downloaded. See chapter “Functional Test” for
more details
OPTION 2 (downloading parameters to all devices at once):
In Metra SW go to View\Download and click on the “Download All”button.
Operating parameters are downloaded to all devices in the Metra NET Network.
Check if correct operating parameters were downloaded. See chapter “Functional Test” for
more details
Other manuals for ELS
1
This manual suits for next models
1
Table of contents
Other Metra Electronics Controllers manuals