Welcome to use ST05C infrared motion sensor!
The product adopts good sensitivity detector and integrated circuit. It gathers automatism,
convenience, safety, saving-energy and practical functions. It utilizes the infrared energy from
human as control-signal source and it can start the load at once when one enters detection field. It
can identify day and night automatically. It is easy to install and used widely.
SPECIFICATION:
Power Source: 220-240V/AC Detection Range: 360°
Power Frequency: 50/60Hz Detection Distance: 6m max(<24℃)
Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40℃
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.15min±2min Power Consumption: approx 0.5W
Rated Load: Max.2000W Installation Height: 2.2-4m
1000W Detection Moving Speed: 0.6-1.5m/s
FUNCTION:
Can identify day and night: The consumer can adjust working state in different ambient light. It
can work in the daytime and at night when it is adjusted on the “sun” position (max). It can
work in the ambient light less than 3LUX when it is adjusted on the “3” position (min). As for
the adjustment pattern, please refer to the testing pattern.
Time-Delay is added continually: When it receives the second induction signals within the first
induction, it will restart to time from the moment.
Good sensitivity Poor sensitivity
INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units,
light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Please move the upper cover with anti-clockwise whirl as per the
diagram on the right.
Connect the power and the load according to the connection-wire
diagram.
Fix the bottom on the selected position with the inflated screw.
Install back the upper cover on the sensor, then you could switch on
the power and test it.
CONNECTION-WIRE DIAGRAM (See the right figure)
SENSOR INFORMATION:
TEST:
Turn the TIME knob anti-clockwise on the minimum
(10s).Turn the LUX knob clockwise on the maximum
(sun).
Switch on the power; the sensor and its connected
lamp will have no signal at the beginning. After
Warm-up 30sec, the sensor can start work .If the
sensor receives the induction signal, the lamp will turn on. While there is no another induction
signal any more, the load should stop working within 10sec±3sec and the lamp would turn off.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX,
the sensor would not work and the lamp stop working too. If the ambient light is less than
3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work! If the lamp is more than 60W, the distance between lamp and
sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive the
signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
The wires come in and
out from the bottom
The wires come in and
out from the side
Height of installation:2.2-4m
Detection Distance: Max.6m

Popular Security Sensor manuals by other brands

LEDISONS LDA90-4-WIT manual

LEDISONS

LEDISONS LDA90-4-WIT manual

Leviton ZLS10-ILW installation instructions

Leviton

Leviton ZLS10-ILW installation instructions

MSA CutOff operating manual

MSA

MSA CutOff operating manual

MSA OptiVizor Instructions for use

MSA

MSA OptiVizor Instructions for use

Bresser 7009999 instruction manual

Bresser

Bresser 7009999 instruction manual

Tecnoalarm EXPLORER II Instructions for use

Tecnoalarm

Tecnoalarm EXPLORER II Instructions for use

Edimax AI-2003W Quick installation guide

Edimax

Edimax AI-2003W Quick installation guide

RKI Instruments 35-3010RK-04 manual

RKI Instruments

RKI Instruments 35-3010RK-04 manual

Lince 1866BABY-BA/E Installation, operation and maintenance manual

Lince

Lince 1866BABY-BA/E Installation, operation and maintenance manual

Bosch PAVIRO Series Operation manual

Bosch

Bosch PAVIRO Series Operation manual

ipf electronic UT18002E manual

ipf electronic

ipf electronic UT18002E manual

Fike Twinflex Multipoint 202-0003 Installation and maintenance instructions

Fike

Fike Twinflex Multipoint 202-0003 Installation and maintenance instructions

KATU 500 Series operation instruction

KATU

KATU 500 Series operation instruction

SICK ELS35 operating instructions

SICK

SICK ELS35 operating instructions

Bosch ISM-BLD1 installation instructions

Bosch

Bosch ISM-BLD1 installation instructions

CST/BERGER LASERMARK LLD20 Original instructions

CST/BERGER

CST/BERGER LASERMARK LLD20 Original instructions

Elmes Electronic CTX3H quick start guide

Elmes Electronic

Elmes Electronic CTX3H quick start guide

Vaisala HMP80 Series user guide

Vaisala

Vaisala HMP80 Series user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.