T -1 Operating Manual Page 9
6 Operating the alarms
If the alarm is activated, the correspondin item on the display will flash. At the same time the externally available alarm
switch will close. The switch will remain closed until any button is pressed to acknowled e the alarm or until the
condition(s) that activated the alarm no lon er exist. The alarm output can be used to switch an external alarm indicator.
The external alarm switch is an open collector transistor switch to round with a maximum ratin of 0.5A DC. It is possible
to wire the alarm contacts of several Stratomaster instruments in parallel should this be desired. To avoid false activation
of the alarms, the alarm function is only active 10 seconds after the instrument has powered up.
7 leaning
The unit should not be cleaned with any abrasive substances. The screen is very sensitive to certain cleanin materials
and should only be cleaned usin a clean, damp cloth.
8 T -1 Specifications
Operating Temperature Range -10ºC to 50ºC (14ºF to 122ºF)
Storage Temperature Range -20ºC to 80ºC (-4ºF to 176ºF)
Humidity <85% non-condensin
Power Supply 8 to 30Vdc SMPS (switch mode power supply) with built in 33V over volta e
and reverse volta e protection
urrent onsumption Approx. 42mA @ 13.8V (backli ht on) 15mA @13.8V (backli ht off)
Display 114x64 raphic LCD display. Contrast and backli ht is user confi urable,
reen/yellow backli ht
AD 12bit over sampled successive approximation
Dimensions see Infinity series dimensional drawin
Enclosure 2 1/4” ABS, black in color, front or rear mountin
Weight Approx. 170 rams
Non-volatile memory storage 100000 write cycles
Thermocouples J-type/K-type and E-Type
Measurement range J-Type/K-Type: -100ºC to 1200ºC (-148ºF to 2192ºF)
E-Type: -100ºC to 900ºC (-148ºF to 1652ºF)
Technology Fully cold junction compensated usin precision internal temperature
reference, built in thermocouple linearization tables
Measurement accuracy +/- 5 de rees typical over full temperature ran e, subject to quality of probe
used. We recommend MGL Avionics EGT and CHT probes
Inputs Differential, can use rounded and isolated probes
ommon mode voltage range -2V to +3V