Microchip Technology PD-9 01GCO/AC Series User manual

PD-9x01GCO/AC
Single Port Outdoor Midspan User Guide
Introduction
Microchip’s PD-9001GCO, PD-9501GCO, and PD-9601GCO is a single-port IEEE® 802.3bt Gigabit PoE outdoor
midspan that offers a cost-effective, IEEE® 802.3at/bt compliant solution that guarantees 30W/60W/90W of power,
and ensures safe and reliable operation in outdoor environments for standard PoE data terminal. These midspans
support 10/100/1000 Mbps data rates and are powered through a wide range of AC inputs (100 VAC to 240 VAC).
These midspans are IP67-rated and have an extended temperature range to be installed outdoors. In a typical
installation, the midspans provide power to outdoor devices such as WLAN AP, WLAN Mesh, or an IP Camera.
These units offers surge protection for both the AC and the PoE ports ensuring that the indoor equipment is protected
from outdoor surges.
PoE midspan powers devices that are PoE enabled or equipped to receive PoE. These devices are called Powered
Devices (PDs).
Note: This user guide contains installation information for the PD-9001GCO, PD-9501GCO, and PD-9601GCO PoE
midspan units. These units are referred to as PD-9x01GCO PoE midspan units in the following section of this
document.
Features
PoE Midspans offer the following key features:
• Outdoor Rated: IP67
• Extended Temperature Range
• Supports 10/100/1000 Mbps Data Rates
• Standards Compliant: IEEE 802.3at/bt
• Plug and Play Installation
• Includes Integrated Surge/Lightning Protection
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 1

Table of Contents
Introduction.....................................................................................................................................................1
Features.................................................................................................................................................. 1
1. Standards and Safety Guidelines............................................................................................................4
1.1. Electrical Compatibility Approvals................................................................................................ 4
1.2. Safety Standard Approvals...........................................................................................................4
1.3. CE Marking...................................................................................................................................4
1.4. GS/D Compliance.........................................................................................................................4
1.5. Surge/Lightning Protection...........................................................................................................4
1.6. Dust and Water Protection........................................................................................................... 5
1.7. Other Standards and Approvals...................................................................................................5
1.8. Safety Information........................................................................................................................ 5
2. Information en Matière de Sécurité......................................................................................................... 6
2.1. Directives Générales....................................................................................................................6
2.2. Mises en Garde............................................................................................................................6
3. PoE Midspan Unit Installation................................................................................................................. 7
3.1. Parts List...................................................................................................................................... 7
3.2. Additional Tools............................................................................................................................ 7
3.3. Installation.................................................................................................................................... 8
4. Installation of Cables.............................................................................................................................14
4.1. AC Power Cable Installation.......................................................................................................14
4.2. RJ45 Cable Installation.............................................................................................................. 15
4.3. Data and Power Connection...................................................................................................... 17
5. Troubleshooting.....................................................................................................................................18
5.1. Preliminary Steps....................................................................................................................... 18
5.2. Troubleshooting Steps................................................................................................................18
6. Specifications........................................................................................................................................ 19
6.1. Environmental Specifications..................................................................................................... 19
6.2. Electrical Specifications..............................................................................................................19
6.3. Interface..................................................................................................................................... 19
7. Technical Support..................................................................................................................................20
8. Revision History.................................................................................................................................... 21
Microchip Information...................................................................................................................................22
The Microchip Website..........................................................................................................................22
Product Change Notification Service.................................................................................................... 22
Customer Support................................................................................................................................. 22
Microchip Devices Code Protection Feature.........................................................................................22
Legal Notice.......................................................................................................................................... 22
Trademarks........................................................................................................................................... 23
Quality Management System................................................................................................................ 24
PD-9x01GCO/AC
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 2

1. Standards and Safety Guidelines
This chapter describes the standards and safety guidelines for the product.
1.1 Electrical Compatibility Approvals
Microchip’s PoE midspan units complies with the following standards:
PD-9001GCO PD-9501GCO PD-9601GCO
EN61000-4-5 Class5 (6KV on AC Lines)
EN55032
EN55035
FCC Part 15
— — EN61000-3-2
EN61000-3-3
VCCI
1.2 Safety Standard Approvals
Microchip’s PD-9x01GCO PoE midspan units meet the following safety standards. Consult Microchip for a complete
list of safety certifications.
• UL/IEC/EN 62368-1
• UL60950-22
1.3 CE Marking
CE marking on this product indicates that this product complies with the Electromagnetic Compatibility (EMC)
Directive.
1.4 GS/D Compliance
GS marking on this product indicates that the product complies with the German Product Safety Act.
D marking on this product indicates that the product complies with the Denmark Product Safety Act.
1.5 Surge/Lightning Protection
Microchip’s PD-9x01GCO PoE midspan units are designed to me the following requirements.
• GR-1089-CORE Lightning Protection Requirements
• ITU K.21 Lightning Protection—Enhanced Level
PD-9x01GCO/AC
Standards and Safety Guidelines
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 4

1.6 Dust and Water Protection
Microchip’s PD-9x01GCO PoE midspan units are designed according to the following requirements.
• IEC60529, Level IP67
• NEMA 250, Level 4x
1.7 Other Standards and Approvals
Microchip’s PD-9x01GCO PoE midspan units are designed according to the following requirements.
• PD-9001GCO/PD-9501GCO: IEEE 802.3at and IEEE 802.3af (PoE) Standards
• PD-9601GCO: IEEE 802.3bt (PoE) Standards
• RoHS Compliant
• WEEE Compliant
• REACH Compliant
1.8 Safety Information
Read the safety information before using the PoE midspan unit.
1.8.1 General Guidelines
Read the following safety information before carrying out any installation, removal, or maintenance procedure on the
PoE midspan. Warnings contain directions to be followed for the safety of personal and product.
1.8.2 Warnings
• Read installation instructions in 3. PoE Midspan Unit Installation before connecting midspan unit to its power
source.
• Follow basic electricity safety measures when connecting the PoE midspan unit to its power source.
• Only trained and qualified personnel must be allowed to install, replace, and service this equipment.
• A voltage mismatch can damage the equipment and can pose a fire hazard. If voltage indicated on the label is
different from the power outlet voltage, do not connect midspan unit to this outlet.
• All wiring and connections must conform to NFPA 70 (NEC).
• Power supply cord must not be attached to the building surface or run through walls, ceilings, floors, and similar
openings in the building structure.
• Measures must be taken to prevent physical damage to the power supply cord, including proper routing.
• Data and Data and Power ports of the midspan unit are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) sockets. Only connect RJ45 data connectors to these sockets.
• When disposing this product, follow all local laws and regulations.
PD-9x01GCO/AC
Standards and Safety Guidelines
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 5

2. Information en Matière de Sécurité
Lire les informations suivantes en matière de sécurité avant d'utiliser d'activer l'alimentation sur votre appareil
Ethernet unité midspan.
2.1 Directives Générales
Lire les informations suivantes en matière de sécurité avant d'installer ou enlever quoi que ce soit, ou procéder à
l'entretien de l'alimentation de votre appareil Ethernet midspan. Les mises en garde contiennent des instructions qui
doivent être suivies pour la sécurité des personnes et du produit. Suivre les instructions soigneusement.
2.2 Mises en Garde
• Lire les instructions d'installation dans 3. PoE Midspan Unit Installation avant de connecter le midspan à une
source d'alimentation.
• Suivre les mesures de sécurité électrique de base lors de la connexion de l'injecteur PoE à sa source
d'alimentation.
• Seul du personnel formé et qualifié doit être autorisé à installer, remplacer et entretenir cet équipement.
• Une disparité de voltage peut endommager l'équipement et constituer un risque d'incendie. Si le voltage indiqué
sur l'étiquette est différent du voltage de la source d'alimentation, ne pas connecter le midspan à cette prise.
• Tout le câblage et les connexions doivent être conformes à la norme NFPA 70 (NEC).
• Le cordon d'alimentation ne doit pas être fixé à la surface du bâtiment ni passer à travers les murs, les plafonds,
les planchers et les ouvertures similaires de la structure du bâtiment.
• Des mesures doivent être prises pour éviter tout dommage physique au cordon d'alimentation, y compris son
acheminement correct.
• Les ports Data et Data et Power du PoE midspan sont des prises de données blindées RJ45. Elles ne peuvent
pas être utilisées comme prises de service téléphonique traditionnel. Connecter seulement des connecteurs de
données RJ45 à ces prises. Le câblage Ethernet connexe doit être limité à l'intérieur de l'immeuble.
• Pour disposer/jeter ce produit, suivre les lois et règlements locaux.
PD-9x01GCO/AC
Information en Matière de Sécurité
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 6

3. PoE Midspan Unit Installation
This chapter describes the procedure to install the midspan unit.
Note: Do not use a cross-over cable between the PoE midspan output port and the load device.
Warnings:
1. Take extra care when connecting the AC power inlet terminals, so that N, L, and Ground are connected to the
proper polarity.
2. Ensure that the AC power is within the allowed range.
3. Earth ground screw must be connected to earth ground in all types of installations.
3.1 Parts List
The following table lists the parts included in the kit.
Quantity Component
1 30W/60W/90W midspan unit, outdoor model
1 AC female connector
1 Quick Installation Guide
3.2 Additional Tools
The following table lists the additional tools required to install the midspan unit.
Quantity Part
1 Screwdriver
1 Wire stripper
1 Solid Wrench No. 27 or Adjustable Wrench
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 7

3.3 Installation
This section describes the prerequisites and available installation options for the midspan unit.
The following figure shows the overview of the midspan unit.
Figure 3-1. Product Overview—Front View
Figure 3-2. Product Overview—Top View
Figure 3-3. Product Overview—Bottom View
3.3.1 Prerequisites
Note the following before mounting the PoE midspan unit to a fixed location:
• To ensure weather-proof connection in order to meet IEC60529 level IP67. PoE midspan AC power plug needs
to be connected to a weather-proof AC power source box.
• Do not cover the midspan or block the airflow to the PoE with any foreign objects.
• Keep the midspan away from excessive heat and free from vibration.
• Ensure that the cable length from the Ethernet network source to the terminal does not exceed 100 meters (333
feet). The midspan is not a repeater and does not amplify the Ethernet data signal.
• The midspan has no ON-OFF switch, simply plug the midspan to an AC power source.
• PoE midspan AC power lines must be connected to the socket-outlet that shall be installed near the equipment
and be easily accessible.
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 8

3.3.2 Earth Ground Connection
Note: Connect the midspan to ground only if replacing pre-assembled ground cable.
1. Connect the chassis bolt to the earth ground point on the rear of the midspan.
2. Connect the other end of the ground wire to earth ground at your installation point.
3. Tighten the screw to 1.1 Nm to 1.7 Nm.
Figure 3-4. Earth Ground Connection
To Earth Ground
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 9

3.3.3 Installation Options
Following are the two options available for the installation of these midspan units:
1. Wall Mounting—PoE midspan unit can be mounted on a wall/bench (all kind of flat surfaces such as wood,
brick, concrete and other) using the mounting holes.
CAUTION
Use only a solid mounting surface to install the midspan unit, do not install on drywall or
plasterboard walls.
2. Pole Mounting—Using the optional mounting kit.
Note: The optional mounting kits are not provided with the midspan unit. Contact 7. Technical Support for
more information on ordering the mounting kits (Part Number: PD-OUT/MBK/GCO or PD-OUT/MBK/ET).
3.3.3.1 Wall Mounting
Follow the procedure to mount the unit directly to a wall.
1. Using the screw holes of the midspan as a template, put marks on the mounting surface (a wall of wood, brick
or concrete) to mark drill points and drill four holes.
2. With the unit attached to the mounting surface, insert four mounting screws through the screw holes on the
unit and into the mounting surface.
Notes:
• For bricks or concrete wall, use anchor screws (5 mm x 40 mm), and for wooden wall, use wood screws
(5 mm x 40 mm).
• The screws are not provided with the kit.
3. Tighten each screw until the midspan unit is securely attached to the mounting surface.
185
118
185
118
185
118
12
34
Note: The dimensions in the above figure are in millimeters.
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 10

3.3.3.2 Pole Mounting
Following are the two options available for the pole installation of this midspan unit.
3.3.3.2.1 Pole Mounting—Using PD-OUT/MBK/ET Kit
Before installing the midspan, ensure that all the following parts listed in the parts list are included. If any items are
missing, notify your Sales or Customer Service Representative from Microchip.
1. Install the midspan onto the mounting bracket of the pole mount adapter, using four pan head screws.
2. Install the mounting bracket onto the pole. Use the appropriate components depending on the diameter of the
pole.
a. Pole of small diameter: The following parts list identifies the components required to install the metal
bracket on a pole with a diameter of 25 mm to 76 mm (1 in. to 3 in.).
b. Pole of large diameter: The following parts list identifies the components required to install the metal
bracket on a pole with a diameter of 76 mm to 203 mm (3 in. to 8 in.).
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 11

3. For poles of both small and large diameter, connect the chassis bolt to the earth ground point on the mount kit.
Warning: Mounting bracket must be connected to earth ground.
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 12

3.3.3.2.2 Pole Mounting—Using PD-OUT/MBK/GCO Kit
Before installing the midspan, ensure that all the items listed in the 3.1. Parts List are available in the kit. If any item
is missing, notify your Sales or Customer Service Representative from Microchip.
Follow the procedure to mount the unit on a pole using a mounting bracket.
1. Attach the pole bracket to the midspan using four pan head screws and tighten the pan head screws to 1.1
Nm.
2. Place the midspan/pole bracket assembly onto the pole. Tighten the midspan/pole bracket assembly to the
pole using worm clams, as shown in the following figures.
Notes:
• Pole bracket supports poles with diameters ranging from 60 mm to 200 mm (2.5 in. to 8 in.).
• The unit must be installed with DATA IN, and DATA & PWR OUT ports facing down, as shown in the
following figures.
PD-9x01GCO/AC
PoE Midspan Unit Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 13

4. Installation of Cables
This chapter describes the procedure to install the cables to the midspan unit.
4.1 AC Power Cable Installation
The following table lists the AC power cable specifications.
Table 4-1. AC Cable Specifications
Parameter Value
Recommended cable type North America—SJOW or SOOW
Worldwide—H05RN-F or H07RN-F
Voltage rating 300V (or better recommended)
Temperature range –40 ℃ to 65 ℃ (or better recommended)
Cable size 16 AWG–18 AWG 3C
1.0 mm2–1.5 mm2 3C
Cable outer dimension ∅ 6.0 mm–10 mm
Approved for indoor and outdoor applications.
Follow the procedure to install the AC cable to the midspan unit.
1. Insert a screwdriver, press and rotate counter-clockwise to unlock the cap. Remove the cap from the midspan
unit.
2. The connector consists of the following parts.
Clamping
NUT
Seal BodyClamp spring Body Female
Housing
3. Insert the AC cable through the parts, crimp, and screw the wire leads to 0.8 Nm torque.
NL
PE
4. Push Housing into Body according to lead rails, as shown in the following figure.
PD-9x01GCO/AC
Installation of Cables
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 14

Lead Rails
5. Insert Seal and Clamp spring into the body and tighten the Nut to 4 Nm torque.
4.2 RJ45 Cable Installation
The following steps describe how to install the RJ45 cable to the midspan unit.
1. Remove the upper cap, blank plug, and washer from the DATA IN port.
2. Insert the cable through the upper cap and the washer and plug into the DATA IN port.
3. Slide the washer and the upper cap towards the midspan and hand-tighten the upper cap onto the DATA IN
port.
Note: Secure the gland until the rubber gasket is firmly closed around the cable.
PD-9x01GCO/AC
Installation of Cables
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 15

Need to secure gland till rubber gasket is tightly closed around the cable
4. Repeat step 1 to step 3 to connect the RJ45 cable to the DATA & PWR OUT port.
5. Verify connection to main AC power.
Notes:
1. 2-ports RJ45 male plug waterproof cap covers are supplied with the PoE Midspan.
2. ACIN plug is supplied with the PoE Midspan.
3. AC power cable, Ethernet cable, and RJ45 male connectors are not supplied with the PoE Midspan.
4. For non AF/AT compliant unit—use a splitter; ensure that the splitter is connected close to the terminal and not
on the midspan.
5. These units are designed for outdoor use only.
PD-9x01GCO/AC
Installation of Cables
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 16

4.3 Data and Power Connection
Note: The midspan has no ON-OFF switch, simply plug the midspan into an AC power source.
Follow the procedure to connect the data and power source to the midspan unit.
1. Connect the DATA IN (input) jack from the midspan to remote Ethernet network (item 2 in the following figure).
2. Connect the DATA & PWR OUT (output) jack from the midspan to the terminal (item 3 in the following figure).
3. Connect AC power lines from the LINE IN terminal (item 1 in the following figure) to main AC power. Ensure
that the power outlet is nearby and easily accessible.
Note: Connect the midspan unit to a weather-proof AC power source box that meets IP66 and IP67 ratings.
Label Description
1 LINE IN Power input, 100 VAC–240 VAC
2 DATA IN Data in to the Ethernet (network) switch
3 DATA & PWR OUT Data and power out to the Ethernet terminal
PD-9x01GCO/AC
Installation of Cables
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 17

5. Troubleshooting
This chapter describes the troubleshooting procedures to address any problems encountered with the midspan unit.
5.1 Preliminary Steps
If there is any problem, verify the following steps:
• Power is applied to the midspan unit.
• A crossover-type Ethernet cable has not been used.
• Ethernet cable from network is connected to Data In port.
• Ethernet cable to PD is connected to Data and Power Out port.
• Cable pairs are attached to their corresponding ports.
5.2 Troubleshooting Steps
The following table lists the problem and resolution sequence to assist in troubleshooting of minor operating
problems. If the following steps do not solve your problem, contact your local dealer for further assistance.
Table 5-1. Troubleshooting Steps
Problem Corrective Steps
Midspan does not power-
up
1. Verify a reliable power cord is used.
2. Make sure that the power cord is properly connected.
3. Verify that the voltage at power inlet is between 100 VAC–240 VAC.
4. Remove and reapply power to the device during power-up sequence.
PD does not operate 1. Verify that the port is enabled (midspan did not detect a PD).
2. Verify that the PD is designed for PoE operation.
3. Verify that you are using a standard Category 5/5e/6, straight-wired cable, with
four-pairs according to data rate.
4. If an external power splitter is in use, replace it with a viable splitter.
5. Verify that the Data source is connected to the Data In port.
6. Verify that the PD is connected to the Data and Power Output port.
7. Verify that there is no short over any of the twisted-pair cables or over the RJ45
connectors.
End device operates, but
there is no data link.
1. If an external power splitter is in use, replace it with a viable splitter.
2. Verify that for this link you are using a standard UTP/FTP Category 5 straight
(non-crossover) cabling, with all four pairs.
3. Verify that the Ethernet cable length is less than 100 meters from Ethernet
source to the remote terminal.
PD-9x01GCO/AC
Troubleshooting
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 18

6. Specifications
This chapter lists the specifications of PD-9x01GCO PoE midspan units.
6.1 Environmental Specifications
Table 6-1. Environmental Specifications
Mode Temperature Humidity
PD‑9001GCO/PD‑9501GCO PD-9601GCO
Operating –40 °C to 65 °C
–40 °F to 149 °F
–40 °C to 60 °C
–40 °F to 131 °F
10% to 90%
(non‑condensing)
Storage –40 °C to 85 °C
–40 °F to 185 °F
6.2 Electrical Specifications
Table 6-2. Electrical Specifications
Parameter PD-9001GCO PD-9501GCO PD-9601GCO
Value
Input voltage 100 VAC–240 VAC (50 Hz/60 Hz)
Input current 1.4A (maximum) 1.3A (maximum)
Available output power
(maximum)
30W 60W 90W
Nominal output voltage 54 VDC
6.3 Interface
Table 6-3. Interface
Parameter Type
PD-9001GCO PD-9501GCO/PD-9601GCO
Input (Data In): Ethernet
10/100/1000Base-T
RJ45 female socket RJ45 female socket
Output (DATA PWR OUT): Ethernet
10/100/1000, plus 54 VDC
RJ45 female socket, with DC
voltage on wire pairs: 4-5 and 7-8
RJ45 female socket, with DC voltage
on wire pairs: 3-6, 4-5 and 1-2, 7-8
AC Power IN 3 Pins AC power-in—Line, Neutral
and Earth Ground
3 Pins AC power-in—Line, Neutral and
Earth Ground
PD-9x01GCO/AC
Specifications
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 19

7. Technical Support
If you encounter problems while installing or using this product, consult the Microchip technical support team through
the website or contact on the following number:
USA/Canada
Telephone: +1 877 480 2323
Internet: www.microchip.com/support
PD-9x01GCO/AC
Technical Support
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003422A-page 20
This manual suits for next models
3
Table of contents
Languages:
Other Microchip Technology Network Hardware manuals