Microlife BC 100 Soft User manual

IB BC 100 Soft EN-AP 1120
BC100 Soft
Manual Breast Pump
Microlife BC 100 Soft
1
EN 1
Globalcare Medical Technology Co., Ltd
7th Building, 39 Middle Industrial Main Road,
European Industrial Zone,
Xiaolan Town, 528415 Zhongshan City,
Guangdong Province, PRC
Donawa Lifescience Consulting Srl
Piazza Albania, 10
00153 Rome / Italy
2
3 4

Microlife BC 100 Soft
4
3
2
1
5
6
7
8
BC 100 SoftGuarantee Card
Name of Purchaser
Serial Number
Date of Purchase
Specialist Dealer
2
Intended use:
This device must be used exclusively for pumping breast milk from
nursing mothers. Do not use this device on animals. The device is
only intended for domestic/private use, not for commercial use.
Please read through these instructions carefully in order for you to
understand all functions and safety information.
Dear Customer,
This device allows nursing mothers to express their breast milk
easily and in the comfort of their own homes. If not enough breast
milk is taken from mothers who have recently given birth, this can
lead to the painful build-up of milk, which in the worst-case
scenario could cause inflammation of the nipples (mastitis). This
build-up of milk can be prevented through targeted expressing of
breast milk using the breast pump. In addition, breast pumps help
to alleviate cracked or sore nipples. The breast pump also allows
you to store breast milk in the bottle, for example if you will be trav-
elling or away from your baby for an extended period of time.
Babies who cannot be breast-fed directly for health reasons (due
to a premature birth or cleft palate) can still be given breast milk by
using the breast pump.
If you have any questions, problems or want to order spare parts
please contact your local Microlife-Customer Service. Your dealer
or pharmacy will be able to give you the address of the Microlife
dealer in your country. Alternatively, visit the internet at
www.microlife.com where you will find a wealth of invaluable infor-
mation on our products.
Stay healthy – Microlife AG!
Table of Contents
1. Explanation of Symbols
2. Important Safety Instructions
• Safety and protection
3. Using the Device for the First Time
• Assembling the device
•Cleaning and sterilising the device
4. Directions for Use
• Tips to ensure a better milk ow
• Operating the device
• Storing the breast milk
• Feeding with the breast milk
5. Malfunctions and Actions to take
6. Guarantee
7. Technical Specifications
Guarantee Card (see Back Cover)
Microlife Manual Breast Pump BC 100 Soft EN
1Manual pump attachment (2 levels)
2Silicone membrane
3Silicone valve
4Silicone cushion (standard size)
5Bottle (180 ml)
6Bottle holder
7
8
Screwed plug for bottle
Adapter for AVENT (the device can also be used with this
bottle if desired)
Follow Instructions for Use. This document provides
important product operation and safety information
regarding this breast pump. Please read this
document thoroughly before using the device and
keep for future reference.

3BC 100 Soft EN
1. Explanation of Symbols
NOTE:
Note on important information
2. Important Safety Instructions
Safety and protection
Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device
and keep for future reference.
This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
Keep packaging material away from children to avoid danger of
suffocation.
Keep small parts out of reach of children.
Children must not play with the device.
Cleaning and user maintenance must not be performed by chil-
dren unless supervised.
This device should only be used with original accessories as
shown in these instructions.
For hygiene reasons, the device may only be used on one
person. Do not share the device with other nursing mothers.
The device must only be used on the female breast.
WARNING
Warning instruction indicating a risk of injury or damage
to health
IMPORTANT
Safety note indicating possible damage to the device/
accessory
Manufacturer
CE Marking of Conformity
Never place the device in the microwave.
Never heat up breast milk in the microwave as it may be heated
unevenly and could burn your child when they drink it.
This device must not be used by people with reduced physical,
sensory or mental skills or a lack of experience or knowledge.
Repairs must only be carried out by Customer Services or
authorised retailers. Under no circumstances should you open
or repair the device yourself, as faultless functionality can no
longer be guaranteed thereafter. Failure to comply will result in
voiding of the warranty.
The device requires no calibration.
No modification to the device is permitted.
WARNING
Child safety
This device may only be used under adult supervision.
Always check the temperature of the milk before feeding.
Inspect the device before each use.
Do not use any abrasives or anti-bacterial cleaning agents.
Sterilise all parts that come into contact with the breast milk for
five minutes in boiling water.
Clean the device before each use.
Make sure that the temperature of the liquid in the bottle never
exceeds 50 °C.
Ensure that children do not use this device unsupervised;
some parts are small enough to be swallowed. Be aware of
the risk of strangulation in case this device is supplied with
cables or tubes.
IMPORTANT
When transporting breast milk in the bottle (e.g. when on
the move or travelling), make sure that the bottle cap is
always screwed on tightly.
Follow Instructions for Use. This document provides important
product operation and safety information regarding this breast
pump. Please read this document thoroughly before using the
device and keep for future reference.
Never use the device if feeling drowsy or when asleep.
Never use the device in the bath or the shower.
Do not use this device if you think it is damaged or notice
anything unusual.

4
3. Using the Device for the First Time
NOTE:
Check that the packaging of the device has not been tampered
with and make sure that all components are present. Before
use, ensure that there is no visible damage to the device or
accessories and that all packaging material has been removed.
If you have any doubts, do not use the device and contact your
retailer or the specified Customer Services address.
Assembling the device
Once the device has been removed from the packaging, check the
plastic containers in particular for cracks.
1. Screw the pump attachment 1onto the bottle 5. Ensure the
pump attachment is firmly secured so that no liquid can escape
(see short instruction).
2. Attach the handle for the manual pump including the silicone
membrane by pressing the silicone membrane firmly onto the
pump attachment until it clicks into place (see short instructions).
Cleaning and sterilising the device
WARNING
Clean and sterilise the separate parts of the device that
come into direct contact with the breast milk individually
before first use and any further use.
To sterilise the device correctly, proceed as follows:
1. Unscrew the pump attachment 1from the bottle 5.
2. Remove the silicone membrane 2and silicone valve 3from
the pump attachment.
3. Sterilise the bottle and pump attachment (with silicone
membrane and silicone valve) for five minutes in boiling water or
using a steam steriliser. Do not use the device until all individual
parts are completely dry. Do not use any antibacterial cleaning
products, since these may damage the plastic on the device.
If your breasts are swollen or sore, place a warm towel on them
for a few minutes. This will improve the milk flow.
If the milk does not start to flow from your breasts immediately,
try to relax and then try again a few minutes later.
If the device still does not extract any milk from your breasts
after five minutes, stop using it and try again later.
If you experience any sharp pains when using the device,
consult a doctor.
Operating the device
1. Before using the device, wash your hands and breasts thoroughly.
2. Sit with your upper body lent forwards slightly. You can support
your back better by using a pillow.
3. Then place the breast shield with silicone cushion 4gently on
the breast. Make sure that the nipple is completely enclosed
and there are no air pockets. To ensure proper function, the
breast shield must be drawn firmly onto the breast.
4. You can vary the pump intensity on the manual pump attach-
ment 1by selecting between the MIN/MAX markings that can
be seen. We recommend starting in the MIN position.
NOTE:
See the pictures at the start of the instruction manual for
more information.
Storing the breast milk
Expressed milk can be stored in the fridge or freezer for a certain
period of time.
When storing breast milk, ensure that the device and the bottles
are disinfected before usage. Only store breast milk in disin-
fected containers.
Store breast milk in the fridge or freezer immediately after
expressing. Do not leave breast milk out at room temperature.
If storing breast milk in the freezer, it is recommended that you
mark the bottle with the date of expressing.
4. Directions for Use
Tips to ensure a better milk flow
Choose a time and location to use the device where you can
relax.
Having your child nearby or looking at a picture of your child can
have a positive effect on the milk flow.
If feeding your child using one breast, use the device on the
other breast at the same time.
Warmth and relaxation encourage milk flow. Use the device
after having a shower or bath.

5BC 100 Soft EN
Feeding with the breast milk
NOTE:
You can express the breast milk with an Avent bottle before
feeding (corresponding Avent adapter is included in the box).
Prior to feeding, ensure the bottle has been disinfected before
filling it with the breast milk that has been stored.
To defrost breast milk, store it overnight in the fridge, so as to
retain the nutrients. Once the breast milk is defrosted, it must be
used within 24 hours. Breast milk should only be defrosted in
warm water in especially urgent cases.
If the breast milk smells unpleasant, it should be disposed of
immediately.
Never heat up breast milk in the microwave as it may be heated
unevenly and could burn your child when they drink it.
If heating up the breast milk, check its temperature before
feeding it to your baby.
6. Guarantee
This device is covered by a 1 year guaranteefrom the date of
purchase. The guarantee is valid only on presentation of the
guarantee card completed by the dealer confirming date of
purchase or the receipt.
The guarantee covers the device. Packaging is not included.
Opening or altering the device invalidates the guarantee.
The guarantee does not cover damage caused by improper
handling, discharged batteries, accidents or non-compliance
with the operating instructions.
Please contact Microlife-service.
Defrosted
breast milk
(that had been
frozen)
10 hours Do not refreeze
Room
temperature
Refrigerator
(approx. 3 - 5 °C)
Freezer
(approx. -16 °C)
5. Malfunctions and Actions to take
Use following table for solutions if any problem occur.
Problem Potential solutions
There is no suction from
the device.
Check all parts of the device are
correctly assembled.
Check whether the pump attachment
is correctly placed on the breast.
No breast milk is being
pumped.
Ensure that there is no milk remaining
in the silicone valve and obstructing
the milk flow.
Pumping the breast milk is
causing pain.
Try to relax and then attempt it again a
few minutes later. As you use the
device more and more, you will find it
easier to pump milk.
Set the suction level to MIN.
Consult your doctor.
The breast milk is leaking
out underneath the silicone
cushion.
Remove the silicone cushion and re-
attach it. Ensure the silicone cushion is
correctly positioned and firmly secured
to the pump attachment.
Lean your upper body forwards slightly.
One of the device compo-
nents has become altered
or damaged.
Do not use any corrosive, gaseous
cleaning agents or solvents.
In some cases, marked fluctuations in
temperature can damage the plastic
on the device.
If any of the parts becomes damaged,
stop using the device.
Problem Potential solutions
Use
immediately
WARNING
Observe the storage periods in the following table:
Room
temperature
Refrigerator
(approx. 3 - 5 °C)
Freezer
(approx. -16 °C)
Recently
expressed
breast milk
Can be kept for
6 hoursCan be kept for 24
hours
(Do not store in
the fridge door, as
it is not sufficiently
cool there)
Can be kept for
3 months

5
7. Technical Specifications
u
Child use and care articles - Drinking equipment according to
EN 14350
u
Device for expressing breast milk
The technical specifications may change without prior
notice.
Type: Manual Breast Pump BC 100 Soft
Dimensions:200 x 160 x 66 mm
Weight: 135 g
Maximum
suction
pressure: -0.32 bar
Operating
conditions:
5 - 40 °C
30 - 85 % relative maximum humidity
(non condensing)
700 - 1060 hPa ambient pressure
Storage
conditions:
-20 - +60 °C
10 - 95 % relative maximum humidity
(non condensing)
700 - 1060 hPa ambient pressure
Other manuals for BC 100 Soft
3
Table of contents
Other Microlife Breast Pump manuals

Microlife
Microlife BC 100 Soft User manual

Microlife
Microlife BC 100 Soft User manual

Microlife
Microlife BC 300 Maxi 2 in 1 User manual

Microlife
Microlife BC200 Comfy User manual

Microlife
Microlife BC200 Comfy User manual

Microlife
Microlife BC300 Maxi 2 in 1 User manual

Microlife
Microlife BC300 Maxi 2 in 1 User manual

Microlife
Microlife BC 100 Soft User manual