Microlife NEB 100 User manual

EN APONORM® COMPACT
Compressor unit
Power cord with power plug
On/Off switch
Compartment for air filter
Nebuliser kit
Atomiser
Mouthpiece
Air tube
Adult face mask
Child face mask
Elastic strap
Nose attachment
Dear Customer,
Congratulations of your purchase of the aponorm® by microlife nebuliser Compact.
The device is a high-quality nebuliser to be used in inhalation therapy for the treatment of asthma,
COPD and other respiratory diseases. These instructions describe all functions of your device.
They include important safety information and instructions for the use of the nebuliser. Please
read the information in the operating instructions thoroughly before using the device.
If you have any questions or problems, please contact your local pharmacy. Your pharmacy will
also provide you with any replacement parts required. Your pharmacist is the person to contact for
all questions concerning the nebuliser. For more detailed information on our products please refer
to www.aponorm.de.
We wish you good health at all times! aponorm® –Your pharmacy brand
The aponorm® nebuliser Compact:
•Is suitable for inhalation therapy for the treatment of asthma, COPD and other respiratory
diseases
•Is suitable for professional use (on a regular basis)
•Allows the medication to reach the depths of the lungs
•Features extremely fine nebulization
•Is simple to use
•Features a powerful compressor
•Comes with face masks, mouthpiece, nosepieces, nebuliser kit, air tube and spare air filters
•Can be steam sterilized
•Provides a high efficiency of inhalation
1
Attachment of
elastic strap to mask:

Important!!!
Please read the operating instructions thoroughly before using the nebuliser.
Retain these instructions for further reference.
Important! Please observe the information in this booklet in order to prevent damages to the
blood pressure monitor and avoid error messages.
Type BF applied part
Keep Dry.
Read the instructions carefully before using this device.
Brief instructions
1. Make sure that the power switch is switched off (power switch in the 0 position).
2. Connect the air tube to the nebulizer kit (A) and the device (B). Please make sure that the tube is
securely attached to both valves.
3. Plug the power plug into a power outlet (C).
4. Remove the top from the nebulizer kit. Unscrew the cap of the nebuliser kit by turning it in the
direction of the arrow (D) and lift it off (E).
5. Add the correct amount of medical liquid to the medication tank (F). The liquid must not exceed
the maximum filling level. (min. 2 ml; max. 12 ml) Now screw the top of the nebulizer kit back to
the medication tank. Make sure that the nebuliser kit is kept upright after it has been filled with
the medical liquid.
6. Now attach a face mask, the mouthpiece or the nosepiece to the nebuliser kit (G) and hold the kit
in your hand. It is important to keep the nebuliser kit upright as otherwise the medical liquid may
spill. Start inhaling your medication.
EN APONORM® COMPACT
2

EN APONORM® COMPACT
3
1. Safety information and instructions, use, warranty
Safety
Use the device only for the purpose described in these instructions –as an inhaler for aerosol
therapy. Please observe your doctor's instructions. Any other use of the device is forbidden
and may be dangerous. The manufacturer will not accept any liability for damage caused by
improper use. Retain the instructions for use for later reference.
The device must not be exposed to:
•Water and moisture
•Extreme temperatures (heat and cold)
•Impact load and drop to the floor
•Dirt and dust
•Strong solar irradiation
Warranty
aponorm® by microlife gives a 5 years warranty from the purchase date for this device. To claim
your warranty you need to submit the device warranty card filled in by the pharmacy where you
purchased it. You will find the warranty card for the aponorm® Compact nebuliser on the last page
of these instructions for use.
Please not the following:
•The nebuliser device is covered by the 5 years warranty.
•Opening of or modification to the device by the user voids all warranty claims.
•The warranty does not cover damage caused by improper use, accidents or failure to observe the
instructions for use.
•Wear parts (e.g. mouth- and nosepiece, filter layer, mask) are not covered by the warranty.
Information for use:
•Do not use the device as an anaesthetic apparatus or respirator.
•Thoroughly clean the nebuliser kit after each use. Make sure that all parts are completely dry, and
then store the device in a clean and dry place.
•If the device works improperly or not at all, please refer to the section „Malfunction and remedial
action“.
•Do not open the device housing. Do not perform any repairs yourself. Otherwise perfect function
cannot be guaranteed.
•Do not immerse the device in water.
•Never touch the device with your hands wet or moist.
•Do not store or leave the device to stand outdoors.
•During use the device must be placed on a stable and horizontal surface.
•Ensure that children do not use this device unsupervised; some parts are small enough to be
swallowed. Be aware of the risk of strangulation in case this device is supplied with cables or
tubes.
•Do not use the device if cords or plugs are damaged.
•Do not block the inhalation air inlet.
•Use only medication prescribed by your doctor or medication formulated for use in a nebuliser.
Always observe your doctor's recommendations or the medical information provided by the
package insert.
•Do not use gluey or tenacious consistency, like e.g. essential oils, syrup, cough mixture, medica ted
solution for gargling, ageratum and drops used for vapour-bath.
•Ensure that the air filter is clean at all times. If the air filter changes color or is blocked, replace it
with a new one.
•Do not tilt the nebuliser kit at an angle of more than 45°.
•Do not shake the device while it is in use.
•Unplug the power plug before cleaning the device.

EN APONORM® COMPACT
4
2. Preperation
We recommend cleaning and disinfecting all components before initial use as described in section
„Cleaning and disinfection“.
1. Make sure that the power switch is switched off
(power switch in the 0 position).
2. Plug the power plug into a power outlet.
3. Connect the air tube to the nebuliser kit (A) and the device (B).
Please make sure that the tube is securely attached to both valves.
4. Remove the top of the nebuliser kit. Unscrew the cap of the nebuliser
kit by turning it in the direction of the arrow (D) and lift it off (E).
5. Add the correct amount of medical liquid to the medication tank (F).
The liquid must not exceed the maximum filling level.
(min. 2 ml; max. 12 ml)
6. Screw the top of the nebuliser kit back to the medication tank.
Make sure that the nebuliser kit is kept upright after it has been filled with the medical liquid.
3. Use of the attachments, inhalation
1. Hold the nebuliser kit in your hand. 2. Please attach the mouthpiece,
1. It is important to keep the nebulizer 2. nosepiece or mask (adult/child)
1. kit upright as otherwise the medical 2. to the nebuliser kit.
1. liquid may spill.
Sit upright and relax. Do not lie
down for inhalation.

Lower respiratory tract (Bronchia)
Here we recommend the use of the mouthpiece.
When you inhale the medicine through the mouthpiece the particles are taken directly to the lower
respiratory tract. Of course you can use the face mask as well, but in this case the particles do not
reach the lower respiratory tract directly, but rather just the bronchus. Therapy is not as effective
as when using the mouthpiece.
Use of the mouthpiece:
Take the mouthpiece between your lips and breathe in through your mouth, inhaling the medication.
Breathe out normally through the mouthpiece.
3. Turn the mains switch on the compressor unit to 1. The compressor
3. starts up, the nebulization process starts. The inhalation time depends
3. on the medication quantity. Always observe the medical information
3. provided by the package insert of the medication or ask your doctor or
3. pharmacist.
Central respiratory tracts (Chest/lung tract)
Here we recommend the use of the face mask as it reliably takes the medication to the bronchus.
Connect the mask to the nebuliser kit.
For donning the mask hold it between your thumb and index finger and place it over your mouth and
nose. Now pull the elastic strap of the mask over your head to fix the mask. When donning the
mask make sure that the medication tank is kept upright to prevent spilling of the liquid
Use of the face mask:
Don the mask so that it covers your nose and mouth and breathe in, inhaling the medication. Breathe
out normally through the mask.
3. Turn on the power switch of the compressor.
Upper respiratory tract (nose/throat or throat/pharynx)
For treating throat and nose we recommend the use of the nose attachment.
However, for treating rather the throat and pharynx you should use the mask.
Connect the nose attachment or mask to the nebuliser kit.
Use of the nose attachment:
Hold the nosepiece to your nose and breathe in, inhaling the medication. Breathe out normally
through your mouth.
3. Turn on the power switch of the compressor.
EN APONORM® COMPACT
5
Switch the device off at the end of your therapy. Please check that the air tube does not
hold any moisture. If condensate has formed in the air tube, remove just the nebulizer kit
and switch the device on again. Leave it switched on and operating until the tube is dry on
the inside. If you store the tube with condensate or moisture inside, bacteria may
proliferate and cause an infection.

EN APONORM® COMPACT
6
4. Malfunction, remedial action
The device does not start.
•Ensure that the power plug is properly connected to the power outlet (plugged in).
•Ensure that the On/Off switch is in position "1".
•The device may have switched off due to overheating. Wait for the device to cool off and switch it
on again.
The nebularisation output of the device is insufficient (nebularisation rate too low or none at all).
•Make sure that the air tube is properly connected at both ends.
•The air tube must not be damaged, compressed, bent, dirty or blocked or clogged. If necessary,
replace the air tube.
•Make sure that the nebuliser kit is properly assembled.
•Make sure that the correct quantity of inhalation solution is filled in.
•Make sure that all components are well cleaned.
5. Cleaning and maintenance
Thoroughly clean all accessories after each treatment in order to remove any medication residues and
potential dirt/contamination. The compressor and the air tube must only be cleaned on the outside
using a clean and moist cloth. We recommend to disinfect the nebuliser at least once a day.
•Always scrub your hands thoroughly before cleaning and disinfecting the accessories.
•Never expose the compressor unit to water or heat.
•If several persons use one device, each of these persons must have their own complete kit. Change
it before the treatment of a new person or replace it if it is dirty/contaminated.
Cleaning:
•Clean all nebuliser accessories (except for the air tube) for approx. 5 minutes under warm tap water
and add a bit of dishwashing liquid (max. 60 °C).
•Thoroughly rinse all components. Make sure that all deposits are removed; leave all parts to dry
completely.
•If some parts are very dirty and soiled a clean brush could be used as well.
Disinfection:
•Always disinfect the fragmented nebuliser and used components (except the air tube) after regular
cleaning. Important because only clean materials can be disinfected effectively.
•All nebuliser accessories (except for the air tube) can be cleaned using chemical disinfectants.
Please observe the instructions of the disinfectant manufacturer.
In boiling hot water:
Put the component parts of the nebuliser (except for the air tube, the masks and the compressor unit)
at least 15 minutes in boiling hot water. Use a clean pot and fill it with enough water. Plastic material
could melt while touching the hot ground of the pot.
Sterilisation:
•All nebuliser accessories (except for the air tube, the masks and the compressor unit) can be
sterilised using hot steam: up to 121 °C (20 min.) or up to 134 °C (7 min.) EN554/ISO1134.
•If available you are also able to use a thermic, usual in trade disinfection tool for baby bottles.
•After sterilisation leave all accessories to cool down to ambient temperature. They can be used
again only after having cooled down. Do not repeat the sterilisation process while the accessories
are still warm. You can order all replacement parts and accessories from your local pharmacy.
Do not repeat the sterilisation process while the accessories are still warm. You can order all
replacement parts and accessories from your local pharmacy.

Replacement of filter
•We recommend the regular replacement of the atomiser unit, the mouthpiece, the nose
attachment and the masks due to wear.
•Check the filter for contamination on a regular basis and replace it if necessary. A replacement filter
is supplied along with the device.
•To replace the filter open the air filter compartment on the top of the unit (identified with "Filter").
6. Technical data
Designation: aponorm® by microlife nebulizer compact
Model: NEB 100
Type: Non-heating compressor-nebuliser
Tension supply: 230 V, 50 Hz
Power input: 150 VA
Weight: approx. 1.2 kg
Dimensions: approx. 140 (w) × 120 (h) × 150 (d) mm
Nebularisation quantity: 0.35 ml / min. (NaCl 0.9 %)
Particle size: 75 % < a 5 μm (NaCl 0.9 %)
Max. airflow: 12 l / min
Noise level: 56 dBA
Operational Pressure: 60 kPa (0.6 bar)
Length of power cord: 1.5 m
Filling quantity of nebuliser: min. 2 ml; max. 12 ml
Residual quantity: 0.7 ml
Operating conditions: temporary use 30 / 30 min I / O
Operating temperature: 10 to 40 °C / 50 to 104 °F
10 –95 % relative maximum air humidity
Storage temperature: -25 to +70 °C / -13 °F to +158 °F
10 –95 % relative maximum air humidity
700 –1060 hPa
IP Class: IP 20
Expected servvice life: 5 years
Reference to pertinent standards: EN 13544-1; EN 60601-1; EN 60601-1-2;
CE0434; IEC 60601-1-11
Contents of the package
Compressor with power cord, Nebuliser unit including atomizer, Air tube (PVC, 100 cm), 3 replacement
filters, Mouthpiece (PP), Adult face mask (PVC), Child face mask (PVC), Elastic strap, Nosepiece (PP),
Instructions for use, Soft bag
Notes
•Subject to technical changes without notice.
•It may be the case that the device does not work if the temperature or voltage does not correspond
to the values indicated in the technical data.
Disposal
Electronic devices must not be disposed of as normal domestic waste, but they must be
disposed of in accordance with the local provisions valid. The function of this device may be
compromised when used close to strong electromagnetic fields such as mobile phones or radio
installations and we recommend a distance of at least 1 m. In cases where you suspect this to
be unavoidable, please verify if the device is working properly before use.
EN APONORM® COMPACT
7

EN APONORM® COMPACT
8
3A Health Care S.r.l.
Via Marziale Cerutti 90/F,
Loc. San Tomaso,
25017 Lonato (BS) / Italy
Other manuals for NEB 100