logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3M
  6. •
  7. Respiratory Product
  8. •
  9. 3M 8810 User manual

3M 8810 User manual

Other 3M Respiratory Product manuals

3M Air-Mate PAPR User manual

3M

3M Air-Mate PAPR User manual

3M Breathe Easy PAPR Configuration guide

3M

3M Breathe Easy PAPR Configuration guide

3M 8000 Series User manual

3M

3M 8000 Series User manual

3M 8822 User manual

3M

3M 8822 User manual

3M 6100 User manual

3M

3M 6100 User manual

3M 8835 User manual

3M

3M 8835 User manual

3M AIRMATE Manual

3M

3M AIRMATE Manual

3M 7500 Series User manual

3M

3M 7500 Series User manual

3M Aura Particulate Respirator 9300+Gen3 Series Instruction Manual

3M

3M Aura Particulate Respirator 9300+Gen3 Series Instruction Manual

3M Air-Mate PAPR 231-01-30 User manual

3M

3M Air-Mate PAPR 231-01-30 User manual

3M 8214 User manual

3M

3M 8214 User manual

3M 9001 User manual

3M

3M 9001 User manual

3M 8200 User manual

3M

3M 8200 User manual

3M 9936 User manual

3M

3M 9936 User manual

3M 820007023 User manual

3M

3M 820007023 User manual

3M Particulate Respirator N95 User manual

3M

3M Particulate Respirator N95 User manual

3M Speedglas Adflo User manual

3M

3M Speedglas Adflo User manual

3M Versaflo TR-603E-ASB User manual

3M

3M Versaflo TR-603E-ASB User manual

3M 9310 User manual

3M

3M 9310 User manual

3M 7800 Installation instructions

3M

3M 7800 Installation instructions

3M Versaflo BT-54 Installation and operation manual

3M

3M Versaflo BT-54 Installation and operation manual

3M FF-403 User manual

3M

3M FF-403 User manual

3M 6000 User manual

3M

3M 6000 User manual

3M GVP Series User manual

3M

3M GVP Series User manual

Popular Respiratory Product manuals by other brands

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

DeVilbiss UltraNeb user manual

DeVilbiss

DeVilbiss UltraNeb user manual

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

JARDIBRIC KPBRU20 instructions

JARDIBRIC

JARDIBRIC KPBRU20 instructions

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

EVOLU Nano AiR MINI user manual

EVOLU

EVOLU Nano AiR MINI user manual

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

MSA AUER 3S-PF manual

MSA AUER

MSA AUER 3S-PF manual

MSA C420 instructions

MSA

MSA C420 instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

8810 Respirator
Data Sheet
Standards
The product has been tested to the European Norm EN149: 2001
and has met the requirements of category FFP2 in this standard.
The main performance tests in this standard are:
• Filter Penetration
• Total Inward Leakage
• Flammability
• Breathing Resistance
• Performance
The 8810 offers an Assigned Protection Factor of 10 (Nominal
Protection Factor of 12); i.e., it can be used in atmospheres
containing up to 10 times the Workplace Exposure Limit (WEL) of
particulate contaminant as specified in the Health & Safety
Executive Guidance note EH40.
Warnings
• As with the use of any respiratory device, the wearer must
first be trained in the proper use of the product.
• This product does not protect the wearer against gases,
vapours, solvents from paint spray operations or atmospheres
containing less than 19.5% oxygen.
• Use only in adequately ventilated areas containing sufficient
oxygen to support life.
• Do not use when concentrations of contaminants are
immediately dangerous to life or health.
• Leave the area immediately if:
* breathing becomes difficult
* dizziness or other distress occurs
• Discard and replace respirator if it becomes damaged,
breathing resistance becomes excessive, or at the end
of one shift.
• Never alter or modify this device.
Main Features
The 3M 8810 respirator provides lightweight, effective, comfortable
and hygienic respiratory protection against dusts and mists. The
convex shape, twin strap design, foam nose seal and aluminium
nose clip ensure a good face seal over a wide range of face sizes.
The 3M 8810 is exempt from costly time consuming
maintenance requirements.
Applications
• Base Metal Manufacture • Pharmaceuticals
• Laboratories • Foodstuffs e.g. Bagging
• Powdered Additives • Powdered Chemicals
• Sawmills
Approvals
• The 3M 8810 has been shown to meet the Basic Safety
Requirements under Article 10 and 11B of the European
Community Directive 89/686.
• Meets the performance requirements of the European
Standard for filtering facepiece dust respirators
EN149:2001 FFP2
• The product is CE-marked.
Materials
The following materials are used in the production of this product:
• Straps - Natural Rubber
• Nose-clip - Aluminium
• Filter/shell - Polypropylene/Polyester
• Nose foam - Polyurethane
Weight: 8 g
Respiratory protection is only effective if it is correctly
selected, fitted and worn throughout the time when the wearer is
exposed to hazards.
3M offers advice on the selection of products and training in the
correct fitting and usage.
For help with selecting the most appropriate forms of PPE and
relevant Health and Safety legislation, or for more detailed product
information, please contact the 3M Health and Safety Helpline on:
0870 60 800 60 (UK).
For callers within the Republic of Ireland 1800 320500.
05/2007 - CH8810DS
8810 Respirator
Fitting Instructions
Note - do not use with beards or other facial hair
that may inhibit contact between the face and the
edge of the respirator.
1. Cup the respirator in your
hand with the nosepiece at
your fingertips allowing the
headbands to hang freely
below your hand.
2. Position the respirator
under your chin with the
nosepiece up.
3. Pull the top strap over your
head resting it high at the top
back of your head. Pull the
bottom strap over your head
and position it around the
neck below the ears.
4. Place the fingertips of
both hands at the top of the
metal nosepiece. Mould the
nosepiece to the shape of
your nose by pushing
inward while moving your
fingertips down both sides
of the nosepiece. Pinching
the nosepiece using one
hand may result in less
effective respirator
performance.
5. The seal of the respirator on
the face should be
fit-checked prior to wearing in
the work area.
a) Cover the front of the respi-
rator with both hands, being
careful not to disturb the posi-
tion of respirator.
b) Exhale sharply.
A positive pressure should be
felt inside the respirator. If any
leakage is detected, adjust
position of respirator and/or
tension of strap. Retest the
seal. Repeat the procedure
until the respirator is sealed
properly.