arm but not disarm the system. This restriction on code 18 will need to be pre-set by the installer. The code may be
entered at a later time using the master code. Use the user code attributes table in the rear of this user manual to record
the functions for each code.
Adding, Changing or Deleting a user Code
Enter a valid master user code, press keys 1+3 together then enter a new user code then enter # then the user
identifier (1 to 15). Repeat the procedure for adding other new user codes. To delete user codes, follow the same
procedure, but omit the ‘new user code’ step. Finish by entering a #.
Example. To change the master user code from 1234 to 1912 press the following sequence:
(Your current code) (Together) (New code)
Arming the System
Using Quickarm
If your installer has programmed the quickarm option you can arm the system by entering 1then #. For partitioned
systems (Z8020C only) entering 1 # will arm Area A and entering 2 # will arm Area B.
Quick arming Scorpion
Using a User Code
Enter a valid two, three or four digit user code then #.
If all zones are clear, the keypad sounds a repeating sequence of three short beeps for the duration of the exit delay and
the yellow status lamp turns on. The zone lamps for all zones that are arming are also turned on. At the end of the exit
delay the zone lamps extinguish and the system is now armed.
If a zone fault or potential alarm condition exists and the user attempts to arm the system, the lamp(s) for those zone(s)
flash and are accompanied by a repeating sequence of two long beeps. This indicates that one or more of the zones are
faulty or not secured. The panel should be disarmed, the problem located (possible open door or window) and the
system re-armed.
To Arm the System and Exclude a Zone(s)
Enter a valid user code then *(all zone LED’s light) followed by the zone number(s) to be excluded (those zone
LED’s turn off), then press #.
Example: to arm the system with zones 4 and 5 excluded press:
Disarming the System
Follow the same sequence as for arming, enter a valid two, three or four digit user code then #.
The keypad will beep twice and the yellow status light will turn off. A flashing yellow status lamp indicates that one or
more zones have been alarmed. The zone lamps for any zones which have alarmed will flash until the next arming
cycle. Note the zone number(s) and notify your installer, or security monitoring company.
If the yellow status lamp is flashing and no zone lamps are flashing the alarm condition may have been caused by a
system fault, press 8 9 then #on your keypad. The following table indicates the type of alarm condition that has
occurred:
Zone 1 lamp flashes Alarm caused by a nitewatch, two key, medical or fire panic
Zone 2 lamp flashes The battery has discharged or is faulty
Zone 3 lamp flashes Mains power to the alarm has failed
Zone 4 lamp flashes A dialler communications error has occurred
Zone 5 lamp flashes Phone line is faulty or is disconnected