Safety Information
Important Safety Information
♦Installation and removal of the PoE Midspan must be
carried out by qualified personnel only.
♦AC Power Cord Set:
oThe power cord must have regulatory agency
approval for the specific country in which it is being
used (i.e., UL, CSA, VDE, etc.).
oThe power cord must be a three-conductor type
(two current carrying conductors; one ground
conductor) terminated on one end by an IEC 60320
appliance coupler (for connection to the PoE
Midspan), and on the other end by a plug containing
a ground (earthing) contact.
oThe power cord must be rated for a minimum of
250Vac RMS operation, with a minimum rated
current capacity of 5 Amps (or a minimum wire
gauge of 18 AWG (0.75mm2).
: PoE Midspans installed in Australia require power
cords with a minimum wire gauge of 16 AWG (1.0 mm2).
: The PoE injector "Data In" and "Data & Power Out"
ports are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) telephone sockets. Only
RJ45 data connectors may be connected to these sockets.
oThe AC wall socket-outlet must be near the PoE
Midspan and easily accessible. You can remove AC
power from the PoE Midspan by disconnecting the
AC power cord from either the wall socket-outlet or
the PoE Midspan appliance coupler.
oThe PoE Midspan Data In and Data & Power Out
interfaces are qualified as SELV (Safety Extra-Low
Voltage) circuits according to IEC 60950-1. These
interfaces can only be connected to SELV
interfaces on other equipment.
WARNINGS!
♦Read the installation instructions before connecting the
PoE Midspan to its power source.
♦Follow basic electricity safety measures whenever
connecting the PoE Midspan to its power source.
♦A voltage mismatch can cause equipment damage and
may pose a fire hazard. If the voltage indicated on the
label is different from the power outlet voltage, do not
connect the PoE Midspan to this power outlet.
♦The equipment is intended only for installation in a
Restricted Access Location/
Mounting Instructions
Perform the following:
1. Install two screws in the wall or shelf as shown below:
Figure 1: Mounting Instructions
2. Align the unit's mounting slots to capture the surface screws
3. Connect the ground studs as shown below:
Stud diameter = 5 mm
Connect this side
To earth ground
Stud diameter = 5 mm
Figure 2: Stud Connection to Ground
Recycling and Disposal
Disposal instructions for old products. The WEEE (Waste Electrical
and Electronic Equipment) national environmental initiatives has
been put in place to ensure that products are recycled using best
available treatment, recovery and recycling techniques to ensure
human health and high environmental protection. Your product is
designed and manufactured with high quality materials and
components, which can be recycled and reused. Do not dispose of
your old product in your general household waste bin. Inform
yourself about the local separate collection system for electrical and
electronic products marked by this symbol:
Use one of the following disposal options :
1. Dispose of the complete product (including its cables, plugs
and accessories) in the designated WEEE collection facilities.
2. If you purchase a replacement product, hand your complete
old product back to the retailer. He should accept it as required
by the national WEEE legislation.
Ordering information:
•Product Name: Microsemi 9001G-40/SP
•Part Number: PD-9001G-40/SP/AC
•Description: 1-Port 802.3at 40W Gigabit PoE Midspan with
Surge Protection
Document P/N 06-0062-056 Rev. C00
M
Mi
ic
cr
ro
os
se
em
mi
i
9
90
00
01
1G
G-
-4
40
0/
/S
SP
P
U
Us
se
er
r
G
Gu
ui
id
de
e
1
1-
-P
Po
or
rt
t
8
80
02
2.
.3
3a
at
t
4
40
0W
W
G
Gi
ig
ga
ab
bi
it
t
P
Po
oE
E
M
Mi
id
ds
sp
pa
an
n
w
wi
it
th
h
S
Su
ur
rg
ge
e
P
Pr
ro
ot
te
ec
ct
ti
io
on
n
Notice
It is Microsemi’s policy to improve its products as new
technology, components, software, and firmware
become available. Microsemi, therefore, reserves the
right to change specifications without prior notice.
Technical Support
If you encounter problems when installing or using this
product, please consult the Microsemi website at:
http://www.microsemi.com
For technical support, call: +972-9-775-5123
In the USA: 1-877-480-2323
Email: sales.support@microsemi.com
Microsemi Corp.
Covered under one or more of US Patents:
#7,006,815; and 7,437,217.
Functions and Features
The High-Power Gigabit single port PoE (Power over Ethernet) PD-
9001G-40/SP Midspan injects power over data-carrying Ethernet
cabling. It supports the IEEE802.3at and IEEE802.3af standards,
while increasing the output power to 40W. These power levels allow
usage by a new range of Ethernet-based applications such as Video
Phones, 802.11n Access Points, WiMAX Transmitters, PTZ Cameras
& more. The PD-9001G-40/SP Data & Power Output port is designed
to carry Gigabit Ethernet data & power over a standard CAT5e cable,
delivered through all 4-pairs (Alt A: pins 1,2 (-) & 3,6 (+), Alt B: 4,5 (+)
and 7,8 (-)).
PD-9001G-40/SP EMC Compliance:
♦FCC Part 15 class B and EN55022 class B
♦EN55024
♦VCCI
PD-9001G-40/SP Safety Compliance:
♦UL/cUL per EN60950-1
♦GS mark
PD-9001G-40/SP Lightning Protection:
♦Designed to meet GR-1089-CORE lightning protection demands.
Preliminary Steps
♦Ensure that AC power is applied to the PoE Midspan, using an
operational AC cable with an appropriate ground connection.
♦Ensure that output Ethernet cable is connected to the Data&
Power Out port.
♦Verify that power ready Ethernet compatible device is connected.
WARNING
Do not use cross over cable between the PoE Midspan output port
and the load device
Installation
The PoE Midspan may be located on a desktop or wall/bench
mounted using the rear side mounting holes.
: Before mounting the PoE Midspan to a fixed location:
♦Do not to cover PoE Midspan or block the airflow to the PoE
with any foreign objects. Keep the PoE Midspan away from
excessive heat and humidity and free from vibration and dust.
♦Ensure that the cable length from Ethernet network source to
the terminal does not exceed 100 meters (333 feet). The PoE
is not a repeater and does not amplify the Ethernet
data signal.
♦Use a splitter if desired; ensure that the splitter is connected
close to the terminal and not on the Midspan!
♦No “on-off” switch exists; simply plug the PoE Midspan into an
AC power source.
Installing the Unit
1. Connect the PoE Midspan to an AC outlet (100-240VAC), using a
standard power cord.
2. Connectthe Data In jack (input) to the remote Ethernet network switch's
Patch paneland the Data & Power Out jack (output) to the terminal.
3. Connect the chassis screw connection to the main chassis infrastructure
as illustrated on Figure 2.
4. Associated Ethernet wiring shall be limited to inside of the building.
Ethernet
Cat .5 Cable
Terminal
Port Connectivity
Indication
AC Input
Connectivity
Indicator
Figure 3: Connecting the PoE Midspan
Indicators
LED AC (Main) Port
Green Indicates that the
power is ON
(Power is active)
Indicates that a
remote terminal
is connected
Green Blinking
at 1 Hz
- Overload or short
circuit
Green Blinking
at 4 Hz
-
Internal Fault
Condition
12BSpecifications
15BEnvironmental Specifications
Mode Temperature Humidity
Operating
0 to 40°C
32 to 104°F
10 to 90%
(no condensation
allowed)
Storage
-20 to 70°C
-4 to 158°F
10 to 90%
(no condensation
allowed)
13BElectrical Specifications
Input Voltage 100-240 VAC
(50-60 Hz)
Input Current (110 - 220VAC) 0.8 Ampere
(max)
Maximal Available Output Power
40 Watts
Nominal Output Voltage
52 to 56 VDC
16BEthernet Interface
Input (Data In):
Ethernet 10/100/1000Base-T
RJ45 female
socket
Output (Data & Power Out):
Ethernet 10/100/1000Base-T, plus
55VDC
RJ45 female
socket, with DC
voltage on wire
pairs 7-8 and 4-
5.
14BTroubleshooting
Symptom Corrective Steps
Midspan
does not
power up
1. Verify that a reliable cord is in
use.
2. Verify that the voltage at the
power inlet is between 100 and
240 Vac.
3. Remove and re-apply power to
the device and check the indicators
during power up sequence.
A port
indicator is
not lit and
the PD
does not
operate
1. Verify that Midspan detects a
PD.
2. Verify that the PD is designed
for PoE operation.
3. Verify that you are using a
standard Category 5/5e/6, straight-
wired cable, with four pairs.
4. If an external power splitter is in
use, replace it with a known-good
splitter.
Ensure input Ethernet cable is
connected to the Data In port.
5. Verify that the PD is connected
to the Data & Power port.
6. Try to reconnect the same PD
into a different Midspan. If it works,
there is probably a faulty port or
RJ45 connection.
7. Verify that there is no short over
any of the twisted pair cables or
over the RJ45 connectors.
The end
device
operates,
but there is
no data
link
1. Verify that the port indicator on
the front panel is continuously lit.
2. If an external power splitter is in
use, replace it with a known-good
splitter.
3. Verify that for this link you are
using standard UTP/FTP Category
5 straight (non-crossover) cabling,
with all four pairs.
4. Verify that the Ethernet cable
length is less than 100 meters from
the Ethernet source to the
load/remote terminal.
5. Try to reconnect the same PD
into a different Midspan. If it works,
there is probably a faulty port or
RJ45 connection.

Other Microsemi Network Hardware manuals

Microsemi PD-5524G User manual

Microsemi

Microsemi PD-5524G User manual

Microsemi SyncSystem 4380A User manual

Microsemi

Microsemi SyncSystem 4380A User manual

Microsemi PowerDsine PD-9006G User manual

Microsemi

Microsemi PowerDsine PD-9006G User manual

Popular Network Hardware manuals by other brands

National Instruments DAQ PCI-4451 user manual

National Instruments

National Instruments DAQ PCI-4451 user manual

Honeywell 35 Series user guide

Honeywell

Honeywell 35 Series user guide

hilscher netRAPID Chip Carrier Getting started

hilscher

hilscher netRAPID Chip Carrier Getting started

Costar CR8020XDi quick guide

Costar

Costar CR8020XDi quick guide

Landis+Gyr Gridstream IV Series User and installation guide

Landis+Gyr

Landis+Gyr Gridstream IV Series User and installation guide

Wisenet QRN-420S quick guide

Wisenet

Wisenet QRN-420S quick guide

PROEL STRWIFI user manual

PROEL

PROEL STRWIFI user manual

Raritan MasterConsole Z user manual

Raritan

Raritan MasterConsole Z user manual

Aethra AC2041 Technical specifications

Aethra

Aethra AC2041 Technical specifications

IBASE Technology FWA8207 Series user manual

IBASE Technology

IBASE Technology FWA8207 Series user manual

Klark Teknik DN9650 quick start guide

Klark Teknik

Klark Teknik DN9650 quick start guide

ADTRAN NetVanta T1/FT1 + DSX-1 quick start guide

ADTRAN

ADTRAN NetVanta T1/FT1 + DSX-1 quick start guide

Western Digital My Cloud EX2 Ultra user manual

Western Digital

Western Digital My Cloud EX2 Ultra user manual

Oracle Acme Packet 4600 Hardware installation and maintenance guide

Oracle

Oracle Acme Packet 4600 Hardware installation and maintenance guide

Carrier TeLINK Overview and setup guide

Carrier

Carrier TeLINK Overview and setup guide

DSE DN Series installation manual

DSE

DSE DN Series installation manual

Huawei HES-209M1H user guide

Huawei

Huawei HES-209M1H user guide

Pico Macom TMP-M8 Specifications

Pico Macom

Pico Macom TMP-M8 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.