microSYST MS8202 User manual

COMPETENCE IN
MEASUREMENT
COUNTER
MS8202
v 3.10
USER MANUAL
PLOVDIV 2010
Document revision 2010-0 -03

I. TECHNICAL DATA
Digital inputs 2
Counter NPN или PNP
fmax=330Hz, T1 min=T0 min=1,5ms
Reset Active level 0V
Output 1
K1 Relay 250 V / 5A
Output oltages
+ V +11÷14V_150mA or +24_ 0mA stab. or
+5V 150mA stab.
Display and keyboard
horizontal device 4 digits LED 14 mm
vertical device 4 digits LED 10 mm
Display range
Accuracy
Keyboard
-1999 ... 9999
± 1 LSB
semi-sensor
Power supply
Voltage ~230 V
50 Hz (± 1 Hz)
Operating conditions
Temperature
Relative humidity
0 … 50 °C
0 … 0 % RH
Dimensions
horizontal device 964 12 mm
vertical device 4 9612 mm
Montage
Weight
Panel Cutout 44 x 90 (90x44)mm
max 200 g
Storage
Temperature
Relative humidity
-10 … 70 °C
0 … 95 % RH
Model Until VIII.2010 he MS8202 is manufactured under the name MS8202SPC.
The model and version are displayed when exiting the Options menu
Document revision 2010-0 -03
2

II. FRONT AND REAR PANEL
WIRING INSTRUCTIONS (INPUTS)
Document revision 2010-0 -03
3
GND ISO
RESET

III.OPERATING MODE
The unit registers the input pulses and increases the accumulated value. Upon
reaching the set point, output K1 changes its state or generates a pulse of a certain
duration (see PROGRAMMING mode). The input pulses are blocked until a Reset input
signal resets the counter readings and changes the output status. A new counting starts
after Reset is dropped.
The output status is indicated by LED K1.
The action of the individual buttons is as follows:
By pressing and holding this button for more than 2 seconds, a mode of setting
the limit of accumulated pulses is entered. The display shows a limit value that can be
edited using the UP and DOWN buttons. To save the edited value, press the MODE
button again or do not press the button for more than 5 seconds.
, When one of the two buttons is pressed, the display shows the number
of cycles performed by the counter (it is considered a completed cycle each time the
accumulated value is reset).
While pressing buttons and simultaneously the cycle counter is reset
Pressing and holding this button for more than 5 seconds enters the
"PROGRAMMING" mode, which is indicated by the red LED.
Document revision 2010-0 -03
4

IV. "PROGRAMMING" MODE
The editing of the parameters is done with buttons and , navigating
through the menu and memorizing the parameters is done with a button
m o d e
.
NAME DESCRIPTIONS FAB
Out Output mode:
0 - the output works according to the mode determined by the
PulS parameter.
1 - the output is activated when the set number of pulses is
reached and remains active until external reset.
PulS 0 - the output is active during counting until the set number of
pulses is reached.
0.1 ... 25.5 - after reaching the set number of pulses, the output
is activated for a period PulS (0.1..25.5 seconds).
A message"END" is displayed after the parameters . When a button
m o d e
is
pressed exits the programmed mode.The model and version of the device can be seen in1s
V. OTHER COUNTER OPTIONS
The counter stores the accumulated value and status of its output during power
failure. The next time the power is applied, the unit starts counting from the last
stored value.
The accumulated value can be reset prematurely using the external RESET input.
Document revision 2010-0 -03
5

VI. RECOMMENDATION AGAINST EMI (Electromagnetic
Interference)
Recommendations for use of connecting wires
✔For longer distances for lines subjected to electromagnetic interference, it is desirable
to use a twisted pair wire.
✔For better noise protection, a shielded cable may be used, which must be grounded at
only one end.
✔Wires that carry a similar type of signals can be packed together, but if the signals are
different, the wires must be separated to prevent electromagnetic interaction.
✔When there have to be crossed wires with different signal types this must be done at an
angle of 90 degrees and a long distance.
✔Wires, which carry weak signals and wires connecting the sensors to the controller
must not be near contactors, motors, generators, radios and wires, which carry large
currents.
VII. ORDER CODE
Document revision 2010-0 -03
6
MS8202 - x.x.x.x.x.x.x
Power for COUNT IN
Housing
ode
М1
- box IP 54, 96x48x125
horizontal panel
1М
- BOX IP54, 96x48x125
vertical panel
Dysplay
ode
Т0
Т1
Т2
- N
-
- 24V 80 m stabil. ISO
11...14V 150 m ISO
Power supply
ode
PA
PB
-
- 24 VDC
230 V C
+10%-15%/50Hz
±30% iso
Digital input ISO
R1- RESET npn
ode
R1
G1-
- 14мм-red, 4 Dig
14мм-green, 4 Dig
- 20мм-red, 4 Dig
20мм-green , 4 Dig
- 10мм-red vertical , 4 Dig
10мм-green vertical, 4 Dig
R2
G2-
R5
G5-
ode
K1
AA
AB
AD
- N
- Relay
- Triak
5 /250V
2 / 250V
- OC NPN iso.
AF
U =80V, I =1 *
CEmax Cmax
Power supply -
230 VАС
M 8202 - M1.R2.PA.T1.R1.Q5.AFS
Example :
Display
- LED 20mm red 4 digits
Count input ISO
Q5- fmax=330Hz
Power for COUNT IN Digital input ISO RESET npn
Count input ISO fmax=330Hz

WARRANTY CARD
Warranty card №:.................................................
Warranty term:................................................. months
Factory number:.................................................
The items were purchased from :..................................................................
Invoice number:............................../............. 20........ year .
GUARANTEE CONDITIONS
The guaranty consists in free repairs of all the factory defects which can
occur during the guarantee period. The repair is performed as in the repair base is
being presented the current guarantee card with which the de ice is bought. The
warranty does notrefer to issue caused by a bad transport, bad conservation, wrong
exploitation, naturedisasters, not following the instructions and the cases when there is an
attempt to fix anydefects by other people. In those cases the issue is being fixed only
against payment.
The maintenance during the guarantee period and doing the claims happens
according to the valid legislation.
PERFORMED REPAIRS IN THE SERVICE
Service Date of
receipt
Order
number Type of repairs done
Date of
transmiss
ion
Carried
out the
repair
Seller:................... Buyer:.................
4, Murgash str., Plovdiv city, Bulgaria, 4000
Тел.: (+359 32) 642 519, 640 446 факс: (+359 32) 640 446
Document revision 2010-0 -03
7
This manual suits for next models
1
Table of contents
Popular Cash Counter manuals by other brands

Agilent Technologies
Agilent Technologies 5352B datasheet

Delfield
Delfield Shelleysteel SCFM-50 Specifications

Cassida
Cassida MSD-1000 Series user manual

TSI Instruments
TSI Instruments 3022A instruction manual

DIEBOLD NIXDORF
DIEBOLD NIXDORF DN 490 Operator's manual

impulse Automation
impulse Automation HENGSTLER tico 734 operating instructions