Middle Atlantic Products PD-915RV-RN User manual

PD-915RV-RN
Rackmount Power Strip
Instruction Sheet
- 2 Stage, Normal Mode Spike And Surge Suppression With Led Status Indicators And EMI
Filtering.
- Normally Open Dry Contact Closure For Remote Surge Suppression Status Notification To
Customer Supplied Monitoring Device.
- Two Rear And One Front USB Style, 5 Volt DC Output Ports For Connection Of Optional LED
Gooseneck Work Lights (Part Number LT-GN)
PRODUCT FEATURES
Thank you for purchasing the PD-915RV-RN Rackmount Power Strip.
THANK YOU
POWER CENTER POWER
I
O
SWITCHED
LT-GN
LIGHT ONLY
120 VOLT
PROTECTED
WHEN LIT
Stage 1
Stage 2
PROTECTION
SURGE
FRONT VIEW
2
PDLT-915RV-RN
Status
OPEN - Surge Protection Active
CLOSED - Surge Protection Compromised
SWITCHED
REAR VIEW
I-00168 Rev F

IMPORTANT NOTES
Page 2
DANGER HAZARDOUS VOLTAGE/DANGER HAUTE
TENSION
The lightning flash with the arrowhead symbol, within an
equilateral triangle is intended to alert the user to the
presence of uninsulated dangerous voltage within the
product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
L'éclair avec le symbole de flèche dans un triangle
équilatéral est destiné à alerter l'utilisateur de la présence
d'une tension dangereuse non isolée dans l'enceinte du
produit qui peut être d'une ampleur suffisante pour constituer
un risque de choc électrique pour les personnes.
CAUTION/ATTENTION
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
Le point d'exclamation dans un triangle équilatéral est
destiné à alerter l'utilisateur de la présence d'importants
instructions d’opération et de maintenance (entretien) dans la
documentation accompagnant l'appareil.
READ AND SAVE THESE INSTRUCTIONS!
CONSERVER CES INSTRUCTIONS!
• Contains switched receptacle(s). To reduce risk of shock , disconnect the
device from the power source before servicing any connected
equipment
Contient de(s) receptacle(s) commuté(s). Pour réduire les risques
d'électrocution, débranchez l'appareil de la source d'alimentation
avant l'entretien de tout équipement connecté
• Do not overload the wall outlet where this device is being connected. Do not
overload this device. Ensure the total load to this device does not exceed that
which is listed in the specifications section of this manual
Ne surchargez pas le réceptacle de mur ou le circuit qui fournit l'énergie à ce
appareil. Ne pas surcharger cette appareil. S'assurer que la charge totale à cet
appareil ne dépasse pas celle qui est répertoriée dans la section des
spécifictions de ce manuel
• Ensure this device is connected to a properly grounded AC power source.
Ensure the device is plugged into a source providing the required 120V. Do not
use a plug adapter that defeats the ground pin of the AC plug
Assurez-vous cet appareil est connecté à une source d'alimentation C/A avec
mise à la terre. Assurez-vous cet appareil est branché sur une source
d’alimentation fournissant les nécessaires 120V. Ne pas utiliser un adaptateur
qui contrecarre la broche de terre de la prise du cordon d’alimentation
• There are no user-serviceable components within this device. Removal of the
cover from this device may present a shock hazard, and void the warranty
Il n'ya pas de composants réparables par l'utilisateur au sein de cet appareil.
Retrait de la couverture de cet appareil peut présenter un danger
d'électrocution et annuler la garantie
• To be used indoors in a dry location only
Pour être utilisé en intérieur dans un endroit sec seulement
• Do not operate with a damaged cord or plug
Ne pas faire fonctionner avec un cordon ou une prise endommagée
• Clean only with dry cloth
Nettoyer avec un chiffon sec seulement
NOTE: The MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall
remain readily operable. The socket-outlet shall be installed near the equipment and shall be easily accessible.
IMPORTANT SAFETY INSTRUCTIONS

PDLT-915RV-RN
Status
OPEN - Surge Protection Active
CLOSED - Surge Protection Compromised
SWITCHED
POWER CENTER POWER
I
O
SWITCHED
LT-GN
LIGHT ONLY
120 VOLT
PROTECTED
WHEN LIT
Stage 1
Stage 2
PROTECTION
SURGE
1
5 6 8
109
7
23 4
FRONT VIEW
REAR VIEW
2
1
2
3
4
Page 3
USB PORT FOR GOOSENECK LED LIGHT: Power for optional LT-GN gooseneck light
(sold separately).
NEMA 5-15R OUTLET: Switched 12 AMP/120 VOLT/60 Hz outlet.
SURGE PROTECTION LEDs: Protected when lit (Stage 1 and Stage 2).
POWER SWITCH: Includes integrated circuit breaker with switch guard.
5
6
7
8
NINE FOOT POWER CORD
USB PORT FOR GOOSENECK LED LIGHT: Power for optional LT-GN gooseneck light
(sold separately).
NEMA 5-15R OUTLETS: Eight switched 12 AMP/120 VOLT/60 Hz outlet.
USB PORT FOR GOOSENECK LED LIGHT: Power for optional LT-GN gooseneck light
(sold separately).
9SUPPLEMENTAL GROUNDING AND BONDING STUD
10 TERMINAL BLOCK: Normally Open dry contact closure output provides remote surge suppression
status notification to customer-supplied monitoring device. Status is indicated as follows:
• OPEN - Surge Protection Active
• CLOSED - Surge Protection Compromised
STAGE 1 INDICATOR
ON
OFF
OFF
STAGE 2 INDICATOR
ON
ON
OFF
STATUS
FULL PROTECTION
STAGE 1 COMPROMISED, STAGE 2 ACTIVE
LOAD UNPROTECTED OR POWER OFF
CONNECTIONS, CONTROLS AND INDICATORS

SPECIFICATION
Nominal Line Voltage
Maximum Line Current
Maximum Allowable Voltage
DETAILS
SPECIFICATIONS
120 VAC
12 Amps
125 VACRMS
The product meets the requirements of the following standards:
• UL 60065, 7th Ed,
• CAN/CSA-C22.2 No. 60065, R2012
• UL/CSA 60950-1, 2nd Ed
• UL 1419, 3rd Ed
REGULATORY COMPLIANCE
WARRANTY
Middle Atlantic Products (the "Company") warrants the PD-915RV-RN Rackmount Power Strip to be free from defects in material or workmanship under normal use and conditions for a period of three (3)
years from the date of shipment by the company.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and
refund of the price paid for, or (b) repair or replacement at the Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after inspection
thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or any modification or alteration of the products. In addition, this warranty
does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE
OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER
PARTY) HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY.
Corporate Headquarters Middle Atlantic Canada Factory Distribution
Corporate Voice 973-839-1011 - Fax 973-839-1976 Voice 613-836-2501 - Fax 613-836-2690 USA: NJ - CA - IL Canada: ON - BC
International Voice +1 973-839-8821 - Fax +1 973-839-4982 middleatlantic.ca - [email protected]
At Middle Atlantic Products we are always listening. Your comments are welcome. Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company.
Page 4
Other Middle Atlantic Products Power Strip manuals