Middle Atlantic Products PDC Series User manual

Thank you for purchasing the PDC Series Controlled Power Center.
THANK YOU
PDC Series
CONTROLLED POWER CENTER
Operation Instructions
I-00420 Rev D
REAR VIEW
(PDC-915R-6 Shown)
FRONT VIEW
60 Hz
120
PR OTECTE D
WHEN LI T
St ag e 1 St ag e 2
PROTECTION
SURGE
SWITCHED
ONAU TO O FF
CO NT RO LL ED O UTLE TS
CONTROLLED POWER CENTER
12
I
PDC-915R-6
120V 12A 60Hz
SW IT CH ED
Mi dd le At la nti c Pr od uct s
ACTIVATI ON
Co nt ro lSu rg e
St at us
CON TR OL LE D
NO N C
Ma int ai ne d Mom en ta ry
Re la y
St at us

IMPORTANT NOTES
Page 2
DANGER HAZARDOUS VOLTAGE/DANGER HAUTE
TENSION
The lightning flash with the arrowhead symbol, within an
equilateral triangle is intended to alert the user to the
presence of uninsulated dangerous voltage within the
product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
L'éclair avec le symbole de flèche dans un triangle
équilatéral est destiné à alerter l'utilisateur de la présence
d'une tension dangereuse non isolée dans l'enceinte du
produit qui peut être d'une ampleur suffisante pour constituer
un risque de choc électrique pour les personnes.
CAUTION/ATTENTION
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
Le point d'exclamation dans un triangle équilatéral est
destiné à alerter l'utilisateur de la présence d'importants
instructions d’opération et de maintenance (entretien) dans la
documentation accompagnant l'appareil.
READ AND SAVE THESE INSTRUCTIONS!
CONSERVER CES INSTRUCTIONS!
• Contains switched receptacle(s). To reduce risk of shock , disconnect the
device from the power source before servicing any connected
equipment
Contient de(s) receptacle(s) commuté(s). Pour réduire les risques
d'électrocution, débranchez l'appareil de la source d'alimentation
avant l'entretien de tout équipement connecté
• Do not overload the wall outlet where this device is being connected. Do not
overload this device. Ensure the total load to this device does not exceed that
which is listed in the specifications section of this manual
Ne surchargez pas le réceptacle de mur ou le circuit qui fournit l'énergie à ce
appareil. Ne pas surcharger cette appareil. S'assurer que la charge totale à cet
appareil ne dépasse pas celle qui est répertoriée dans la section des
spécifictions de ce manuel
• Ensure this device is connected to a properly grounded AC power source.
Ensure the device is plugged into a source providing the required 120V. Do not
use a plug adapter that defeats the ground pin of the AC plug
Assurez-vous cet appareil est connecté à une source d'alimentation C/A avec
mise à la terre. Assurez-vous cet appareil est branché sur une source
d’alimentation fournissant les nécessaires 120V. Ne pas utiliser un adaptateur
qui contrecarre la broche de terre de la prise du cordon d’alimentation
• There are no user-serviceable components within this device. Removal of the
cover from this device may present a shock hazard, and void the warranty
Il n'ya pas de composants réparables par l'utilisateur au sein de cet appareil.
Retrait de la couverture de cet appareil peut présenter un danger
d'électrocution et annuler la garantie
• To be used indoors in a dry location only
Pour être utilisé en intérieur dans un endroit sec seulement
• Do not operate with a damaged cord or plug
Ne pas faire fonctionner avec un cordon ou une prise endommagée
• Clean only with dry cloth
Nettoyer avec un chiffon sec seulement
NOTE: The MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall
remain readily operable. The socket-outlet shall be installed near the equipment and shall be easily accessible.
IMPORTANT SAFETY INSTRUCTIONS
The product meets the requirements of the following standards:
• UL 60065, 7th Ed,
• CAN/CSA-C22.2 No. 60065, April 2003, R2012
• UL/CSA 60950-1, 2nd Ed
• UL 1419, 3rd Ed
REGULATORY COMPLIANCE

Page 3
CONNECTIONS, CONTROLS AND INDICATORS
FRONT PANEL FUNCTIONS
Control Status LED: Yellow LED indicates control switch is AUTO
Control Status LED: Green LED indicates controlled receptacles are ON
Master On/Off Circuit Breaker Switch (Factory Position OFF)
Control Switch: (AUTO-OFF-ON) (Factory Position OFF)
Surge Status LEDs (Green): There is one LED for each surge stage, protected when lit
NEMA 5-15R Single Switched Receptacle
4
2
3
5
1
2
3
4
5
External Grounding/Bonding Stud
“Normally Open” or “Normally Closed” control selection switch
“Momentary” or “Maintained” control selection switch
NEMA 5-15R Controlled Receptacles
NEMA 5-15R Switched Receptacles
Controlled Outlet Status Terminal Block
Remote Control Terminal Block provides connection of dry contact (customer provided closure)
Surge Status: provides remote notification of surge status (customer provided closure)
Signal-SafeTM Power Cord
1
2
3
4
5
6
4
7
3
9
1
6
7
3
2
9
1
7
REAR PANEL FUNCTIONS
2
6
5
5
8
PDC-915R-2
6
6
1
4
8
8
9
PDC-915R-6
60 Hz
120
PR OTECTED
WHEN LI T
St a ge 1 St a ge 2
PROTECTION
SURGE
SWITCHED
ONAU TO OF F
CO N TR OLL ED O UTL ET S
CONTROLLED POWER CENTER
12
I
PDC-915R-6
120V 12A 60Hz
SW ITC HE D
Mi d dle Atla n tic P rod u cts
ACTIVATI ON
Co n tr o lS urg e
St a tu s
CON T RO LLE D
NO N C
Ma in tai ne d Mo me nt ar y
Re lay
St a tu s
PDC-915R-2
120V 12A 60Hz
SW ITC HE D
Mi d dle Atl ant i c Pro d uc t s
ACTIVATI ON
Co n tr o lSu r ge
St a tu s
CO N TR OLL ED
NO N C
Ma in ta i ne d Mo me nt ar y
Re lay
St a tu s

The MASTER SWITCH/CB must be on for the receptacles to receive power. Once in the ON position, the unswitched receptacles
will receive power as will the control and surge suppression circuits.
The controlled receptacles receive power via the control circuits under the following conditions:
A) The AUTO-OFF-ON switch is in the ON position.
B) The AUTO-OFF-ON switch is in the AUTO position with the NORMALLY OPEN/CLOSED control selector switch in the
NORMALLY OPEN position and there is a contact closure on the remote control terminal block.
C) The AUTO-OFF-ON switch is in the AUTO position with the NORMALLY OPEN/CLOSED control selector switch in the
NORMALLY CLOSED position and there is no contact closure on the remote control terminal block.
CONTACT CLOSURE OPERATION
The customer provided contact closure connected to remote control terminal block, can be either momentary or maintained.
The MOMENTARY/MAINTAINED selector switch must be in the proper position. The terminal block control closure is
ignored when the AUTO-OFF-ON switch is in the ON or OFF position.
MOMENTARY OPERATION
A contact closure is required for the control PCB to process the control signal. Each subsequent closure will alternately turn off
and on the power to the controlled rececptacles. NOTE: Power cycling the unit via the MASTER SWITCH will cause the controlled
receptacles to revert to the OFF position.
MAINTAINED OPERATION
With the NORMALLY OPEN/CLOSED switch in the NORMALLY OPEN position, a maintained contact closure will energize the
controlled receptacles via the control circuit. When this maintained contact is removed, the recptacles will become de-energized.
With the NORMALLY OPEN/CLOSED switch in the NORMALLY CLOSED position, a maintained contact closure will de-energize
the controlled receptacles via the control circuit. When this maintained contact is removed, the receptacles will become energized.
CONTROLLED OUTLET TERMINAL BLOCK:
The Controlled Outlet Terminal Block provides status of controlled outlets via a dry contact. The CLOSED position indicates the
controlled receptacles are energized, while the OPEN position indicates that the controlled receptacles are de-energized.
SURGE SUPPRESSION (2 STAGE):
There are two green LED indicators on the front panel indicating the condition of the protection circutry.
There is one LED for each of the two stages. Any protective component failure will be indicated by the LEDs being turned off.
In addition to the LEDs, surge suppression component failure will be indicated by a dry contact closure via the rear terminal block.
FUNCTIONALITY REQUIREMENTS
WARRANTY
Middle Atlantic Products (the "Company") warrants the PDC Series to be free from defects in material or workmanship under normal use and conditions for a period of three (3) years from the date of shipment
by the company.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and
refund of the price paid for, or (b) repair or replacement at the Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after inspection
thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or any modification or alteration of the products. In addition, this warranty
does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE
OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER
PARTY) HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY.
Corporate Headquarters Middle Atlantic Canada Factory Distribution
Corporate Voice 973-839-1011 - Fax 973-839-1976 Voice 613-836-2501 - Fax 613-836-2690 USA: NJ - CA - IL Canada: ON - BC
International Voice +1 973-839-8821 - Fax +1 973-839-4982 middleatlantic.ca - [email protected]
At Middle Atlantic Products we are always listening. Your comments are welcome. Middle Atlantic Products is an ISO 9001 and ISO 14001 Registered Company.
Page 4