Electric (EL)
Legend: Abbreviations in bold type:
Connection required en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Options/accessoires:
Dispensing
External dispensing pumps (2 or 4 head pump):
Voltage (external power supply required)
Supplied with supply cable and plug
Pump installation may only be performed by Miele Service.
Machine connections:
Electrical
Standard voltage (2 AC 208V/220-240V 60Hz)
NOTE: Electrical connection depending on version ordered.
Washer (EL1) – 2 AC 208V/220-240V 60Hz
Dryer (EL2) – 2AC 208V 60Hz
Dryer (EL2) – 2AC 220-240V 60Hz
Electrical connection must be in full compliance with
guidelines and with relevant local codes. Similarly, relevant regulations issued
by power utilities, occupational safety authorities and insurance companies as
well as good installation practices should be observed throughout.
Connection to the electrical
supply should only be performed by qualified and
properly trained persons.
Connection using a multi-pole wall lockable socket(s)
IEC/EN 60309 and IEC/EN 60947 is recommended in order to simplify electrical
tests. If machines are hard-wired, a multi-pole main switch must be provided on
site. Switches with a contact gap of more than 3 mm can be used. These
switches, fuses and contactors (IEC/EN 60947). A wall socket or
electrical isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment or checks on the
protective conductor, including determination of correct fuse rating, should only
be performed by a properly trained electrician.
If necessary, equipotential bonding must be provided in accordance with all
appropriate national and local regulations.
Technical datasheet: PWT 6089 EL