Miele PAC 1045 User manual

Operating instructions
Commercial air purifier
PAC1045/1080/1200
To avoid the risk of accidents or damage to the
machine, it is essential to read these instruc-
tions before it is installed and used for the first
time.
en-GB
M.-Nr. 11 855 790

Contents
2
Caring for the environment ............................................................................................ 3
Disposing of filters............................................................................................................. 3
Warning and Safety instructions.................................................................................... 5
Appropriate use................................................................................................................. 5
Foreseeable misuse........................................................................................................... 6
Technical safety................................................................................................................. 6
Product description......................................................................................................... 8
Functional description ....................................................................................................... 9
Using the machine........................................................................................................... 10
Initial commissioning......................................................................................................... 10
Operating the air purifier.................................................................................................... 10
Control panel................................................................................................................. 10
Overview of operating modes ....................................................................................... 11
Overview of operating statuses..................................................................................... 11
Button functions............................................................................................................ 11
Setting the operating mode/calling up the Settings menu............................................ 13
Changing the operating status ...................................................................................... 14
Displaying operating values .......................................................................................... 14
Deactivating the keypad lock ........................................................................................ 14
Settings ............................................................................................................................. 15
Settings menu for “Manual mode”................................................................................ 15
Settings menu for “Manual+time mode”....................................................................... 15
Settings menu for “CO2 mode” .................................................................................... 16
Settings menu for “CO2+time mode” ........................................................................... 17
Settings menu for “Language/Time/Date/Service” ....................................................... 18
Settings menu for “Change filter/Factory defaults/Display contrast” ........................... 18
Installation........................................................................................................................ 19
Transport and installation .................................................................................................. 19
Mounting the adjustable feet............................................................................................. 20
Wall bracket (optional)....................................................................................................... 21
Electrical connection ........................................................................................................ 22
Cleaning and care ........................................................................................................... 23
Filter saturation check ....................................................................................................... 23
Removing fluff and dust from the pre-filter ....................................................................... 25
Cleaning the housing......................................................................................................... 25
Filter replacement.............................................................................................................. 25
Replacing the pre-filters ................................................................................................ 25
Replacing the main filter and active charcoal filter........................................................ 27
Problem solving guide .................................................................................................... 30
Problem solving guide....................................................................................................... 30
Contact in case of malfunction ......................................................................................... 30
Troubleshooting................................................................................................................. 30
Technical data.................................................................................................................. 33

Caring for the environment
3
Disposal of the packaging material
The packaging material protects the air purifier from transport dam-
age. The packaging materials used are selected from materials which
are environmentally friendly for disposal and can therefore be re-
cycled.
Recycling the packaging material reduces the use of raw materials in
the manufacturing process and also reduces the amount of waste in
landfill sites. You can return the packaging to your Miele dealer.
Disposal of your old appliance
Electrical and electronic appliances often contain valuable materials.
They also contain materials which, if handled or disposed of incor-
rectly, could be potentially hazardous to human health and to the en-
vironment. They are, however, essential for the correct functioning of
your appliance. Please do not therefore dispose of it with your house-
hold waste.
Please dispose of it at your local community waste collection / recyc-
ling centre.
Ensure that it presents no danger to children while being stored for
disposal.
Disposing of filters
Any filters that have been used and are contaminated with particulate
as well as filters that are potentially toxic and/or contaminated with
pathogens should be placed in a sealable bag immediately after re-
moval from the appliance. Please follow local regulations and laws
when disposing of the filters.

Caring for the environment
4
Disposing of old batteries
In many cases, electrical and electronic appliances contain batteries
which must not be disposed of with household waste after use. You
are legally obliged to remove any old batteries which are not securely
enclosed by the appliance and take them to a suitable collection
point (e.g. retailer) where they can be handed in free of charge. Bat-
teries may contain substances which can be hazardous to human
health and the environment. If batteries containing lithium (Li-) are re-
moved, the poles must be covered with adhesive tape, for example,
in order to prevent an external short circuit.
The labelling on the battery will provide further information. The bin
symbol with a cross through it means that the batteries must not be
disposed of in household waste. A bin with a cross through it which
also has one or more chemical symbols on it indicates that the bat-
tery contains lead (Pb), cadmium (Cd) and/or mercury (Hg).
3E&G+J
Old batteries contain valuable raw materials which can be recycled.
Disposing of batteries separately makes them easier to handle and
recycle.

Warning and Safety instructions
5
Please read the operating instructions before using the air purifier
for the first time. They contain important information for your
safety, as well as information on using and maintaining the air puri-
fier.
To avoid the risk of accidents or damage, it is essential to read the
operating instructions carefully before using the appliance for the
first time.
If other persons are being shown how to operate the air purifier,
they must be given and/or made aware of these important safety
notes.
Keep these operating instructions in a safe place and pass them on
to any future owner.
In order to ensure your personal safety and prevent damage from oc-
curring or the air purifier from malfunctioning, it is essential to comply
with the safety notes listed below. Failure to observe the instructions
will invalidate any warranty or performance claims.
Appropriate use
The air purifier cleans atmospheric air in frequently used areas and
workspaces. Particles such as pollen, dust, bacteria and viruses are
filtered at a rate of up to 99.995%.
The air purifier is intended for installation in a commercial environ-
ment.
The air purifier is not intended for outdoor use.
Do not install the air purifier in areas where there is a risk of frost.
The appliance components must be protected against direct sunlight,
impact and vibrations, hose water and splash water. Only use the ap-
pliance in indoor environments with ambient temperatures of 0–40°C.
Only trained or qualified personnel may operate the air purifier. If
the air purifier is used in a publicly accessible area (e.g. in schools,
nurseries), the supervisor must ensure that it can be operated safely
without risk of danger.
This air purifier can only be used by people with reduced physical,
sensory or mental capabilities, or lack of experience or knowledge, if
they are supervised whilst using it or have been shown how to use it
in a safe way by an authorised person.
Children under 3 years of age must be kept away from the appli-
ance unless they are constantly supervised.
Children under 8 years of age may only switch the air purifier on or
off if supervised.
Children aged 8 and older may only use the air purifier without su-
pervision if they have been shown how to use it in a safe manner.
Children must be able to understand and recognise the possible
dangers caused by incorrect operation.

Warning and Safety instructions
6
The pre-filters must be vacuumed and/or dust must be removed
from them on a regular basis or as required.
Foreseeable misuse
The air purifier must not be used outdoors.
The air purifier must not be used to filter explosive gases, aggress-
ive atmospheres (vapours) or liquid media.
Do not lean on the air purifier. Otherwise, the air purifier may roll
away or tip over, causing injury to yourself or others.
Do not block the gap between the bottom of the appliance and the
floor with plinth facings, deep pile carpet etc.
The air purifier must not be used at a non-stationary installation
site (e.g. on a ship).
No objects may be placed inside the air purifier. The air intake
vents and air outlet must remain unobstructed at all times and must
not be covered by any objects.
Do not set down or store other objects on the air purifier. Do not
lean ladders or other objects against the air purifier as it may tip over.
In order to prevent a filter or appliance fire, the appliance must not
draw in any sources of danger such as aggressive gases, flammable
media and/or ignition sources (e.g. glowing particles, sparks, smoul-
dering embers, etc.).
Do not operate the air purifier in humid areas at risk of explosion
and/or areas with aggressive atmospheres.
Do not make any alterations to the air purifier, unless authorised to
do so by Miele.
To ensure the correct performance of the air purifier and to prevent
the risk of faults, it is important to carry out maintenance on a regular
basis.
Do not use a pressure washer or water jet to clean the air purifier.
Contaminated filters must not be washed and reused. Cleaning
with fluids that contain solvents presents a risk of fire. Contaminated
filters must always be replaced with new ones.
Never operate the air purifier without pre-filters or with damaged
pre-filters. This could lead to malfunctions. Dust and fluff can clog the
air channels and heater element, which could result in a fire. In this
case, stop the air purifier immediately and replace the damaged fil-
ters.
Technical safety
Before installing the air purifier, check it for visible signs of dam-
age. Do not use a damaged air purifier.

Warning and Safety instructions
7
Do not connect the air purifier to the power supply by an extension
cable (fire hazard due to overheating).
Repairs should only be undertaken by a Miele authorised techni-
cian, otherwise any subsequent damage will not be covered by the
warranty. Unauthorised repairs could result in unforeseen dangers for
the user, for which Miele cannot accept liability.
Faulty components may only be replaced by genuine Miele spare
parts. Miele can only guarantee the safety standards of the appliance
when Miele spare parts are used.
In the event of a fault and for cleaning and maintenance purposes,
the air purifier must be disconnected from the power supply. The air
purifier is only disconnected from the power supply if
- the plug has been removed from the socket or
- the mains fuse is disconnected or
- the screw-out fuse is removed (in countries where this is applic-
able).
See also “Installation – Electrical connection”.
Follow the instructions in “Installation” and “Technical data”.
The plug must be easily accessible so that the air purifier can be
disconnected from the power supply.
If the mains connection cable is faulty it must always be replaced
by a Miele authorised technician to protect the user from danger.
If the air purifier is damaged or if odours during operation indicate
that components are charred, stop using the air purifier immediately.
All filter inserts must be checked/maintained on a regular basis in
accordance with applicable regulations and specifications. Failure to
carry out maintenance will invalidate warranty and performance
claims. Please ask Miele if you require information about maintenance
intervals.
Accessory parts may only be fitted when expressly approved by
Miele. If other parts are used, warranty, performance and product li-
ability claims will be invalidated.
Permanently mounted appliance components must not be re-
moved. Otherwise there is a danger of mechanical and/or electrical
injury due to rotating and/or live components.

Product description
8
12
4
5
6
7
8
3
aLockable access flap
Protects the air purifier controls against unauthorised access.
bAir intake vents
On the left and right sides, rear and bottom of the plinth
cLid with air outlet vents
d4 adjustable feet
4adjustable feet are supplied for optional stabilisation
eControl panel with display
Operation with timed and manual control. The air quality is evalu-
ated via the CO2 sensor.
f4 pre-filters
For separating e.g. spores, pollen, fibres, fluff
gHeater element for deactivating relevant pathogens
With thermal sensor for temperature monitoring
hMain filter (particulate pre-filterISO ePM2.5 60% (F7) and
high-performance filterHEPAH14)
With filtration efficiency of ≥99.995% for particles including vir-
uses (e.g. coronavirus)

Product description
9
Functional description
1. The Miele air purifier draws in atmospheric air at the bottom via
the air intake vents in the plinth().
2. The pre-filters() filter coarse dust out of the air.
3. The air is conveyed upwards by the fan inside the air purifier and
is pushed through the main filter and the active charcoal fil-
ter(). Up to 99.995% of particles are filtered out of the air
during this process.
4. The cleaned air is released back into the room via the air outlet
vents() in the lid.
The control panel() behind the lockable access flap is used to con-
trol the various operating modes (e.g. Manual mode). The fan can be
regulated according to the room size. It is also possible to operate the
appliance based on specified times.
After every use, air heated to 70°C flows through the bottom of the
main filter() for 20minutes.
All components are installed in a high-quality metal housing with
acoustic and thermal insulation. The castors on the bottom of the air
purifier make it easy to move around.

Using the machine
10
Initial commissioning
Before carrying out initial commissioning, it is important to check that
the air purifier is installed in accordance with appropriate use
guidelines. After installation, allow the air purifier to adjust to room
temperature.
Check the air purifier, the plug and the mains connection cable for
damage. If there is any damage, the air purifier must not be used.
Check the fuse rating of the socket before connecting the plug.
Operating the air purifier
The control panel for controlling the air purifier is located behind the
lockable access flap on the front of the plinth.
Check that the mains connection cable and the plug are intact.
Insert the plug into the socket.
Open the lockable access flap on the plinth of the air purifier and
wait for the controls to complete the self-test.
After the self-test, the Modemenu appears.
Mode
Use previous setting
Manual mode
Manual+time mode
In the Modemenu, the operating mode can be selected using the
and buttons. You can use the previous setting (in the factory de-
fault settings, the previous setting is Manual mode) or select a differ-
ent operating mode. To confirm the selected operating mode, hold
down the and buttons for at least 3seconds.
Depending on which operating mode you select, further selectable
options (e.g. flow, clock control, room size) may be displayed. You
can select these options or skip past them by pressing the and
buttons briefly at the same time. The appliance will then switch to
the Ready for operation operating status.
When the appliance is ready for operation, it can be switched on via
the button. If an operating mode with clock (timer) is selected, the
appliance will switch on automatically at the set time.
If you do not select a menu option within 60seconds, the previous
setting will be adopted automatically and the appliance will switch to
the Ready for operation operating status.
After this step, the operating mode can only be changed in the Set-
tingsmenu.
Further selectable options relating to the operating modes may be
available in the Settingsmenu.
Tip: The previous setting can be selected more quickly in the Mode
menu by simply pressing the button or by pressing the and
buttons briefly at the same time.

Using the machine
11
Control panel
12 3
4
5
6
Control panel behind the lockable access flap
abutton
bbutton
cbutton
dGreen LED
Flashes when starting/ready for use, lights up during operation.
eYellow LEDCO2
Flashes in the event of a CO2 warning, lights up when heating is
active.
fRed LED
Flashes in the event of a fault.
Overview of oper-
ating modes
Manual mode During operation, the fan speed can be changed individually between 20–100%
in 5% increments via the and buttons.
Optional initial flow can be switched on before normal operation.
Manual+time
mode Same as Manual mode but with additional clock function (timer) which can be
used to set a switch-on time and switch-off time for each day.
CO2 mode The fan speed is automatically regulated according to the set room size. The need
for ventilation is indicated via an LED and a display message.
Optional initial flow can be switched on before normal operation and a circulation
function can be activated.
CO2+time mode Same as CO2 mode but with additional clock function (timer) which can be used
to set a switch-on time and switch-off time for each day.
Overview of oper-
ating statuses
The following operating statuses are shown in the display:
Ready for opera-
tion
The power supply has been connected and the appliance is ready for operation.
Flow The fan runs at a set flow rate and duration to clean the air before the air purifier
switches to normal operation.
Manual opera-
tion
Manual+time
operation
CO2 operation
CO2+time oper-
ation
The appliance is in normal operation.
ThermoControl
active
Relevant pathogens are deactivated automatically by MieleThermoControl after
every use.
Fan run-on The fan keeps running after MieleThermoControl in order to cool the filter.
Intensive circ.
active
The fan runs at a higher speed for a short period in order to quickly circulate the
air within the room.

Using the machine
12
Button functions The following button functions apply during operation. The logic func-
tion varies depending on the operating status, as detailed below:
Button Type of actu-
ation
Button
function
Logic function
Press,
release
Switch on,
next or
switch off
Switch between operating statuses (see “Changing the op-
erating status”).
Cancel In the Intensive circulation menu: cancel intensive circula-
tion
and
(simultan-
eously)
Short press
(<1sec)
Exit Go back one menu level
Exit the Operating values display menu
When entering a code: exit the code entry level
When entering a value: exit the value entry level without
saving
Temporarily hide warning messages
Long press
(>3sec)
Confirm Access to Settingsmenu
Select a menu element
Deactivate the keypad lock
When entering a value: save the current value entry
Short press
(<1sec)
Up Select the previous menu element
When entering a value: increase the selected position by
one value (+1)
Long press
(>3sec)
Left When entering a value: move one position to the left
Short press
(<1sec)
Down Select the next menu element
When entering a value: decrease the selected position by
one value (-1)
Long press
(>3sec)
Right When entering a value: move one position to the right

Using the machine
13
Setting the oper-
ating mode/call-
ing up the Set-
tings menu
You can change the set operating mode in any operating status by
holding down the and buttons at the same time for at least
3seconds. You will then be prompted to enter the following access
code:
3377
User code
In order to change a digit in the access code, the cursor must be
placed under the relevant digit. The cursor position is changed by
pressing and holding the or arrow button.
To increase the value of the digit (+1), briefly press the button.
To decrease the value of the digit (-1), briefly press the button.
To move the cursor one position to the right, press the button for
3seconds.
To move the cursor one position to the left, press the button for
3seconds.
When all of the code digits are set correctly, confirm the entry by
pressing and holding the and buttons at the same time for at
least 3seconds.
You are now in the Settingsmenu.
Select the required operating mode by holding down the and
buttons at the same time for at least 3seconds.
Depending on which operating mode you select, further selectable
options (e.g. Flow, clock control, Room size) may be displayed. You
can select these options or skip past them by pressing the and
buttons briefly at the same time.
The appliance switches back to the previous operating status with the
newly selected operating mode. If no actions are carried out in the
Settingsmenu within 60seconds, the menu is exited automatically.

Using the machine
14
Changing the op-
erating status If you wish to change the operating status, you can switch between
Ready for operation, Flow (if selected via option), Manual operation/
CO2 operation, ThermoControl active and Fan run-on at any time.
Press the button repeatedly until you reach the desired operating
status.
Tip: If you wish to clean the filter manually via MieleThermoControl,
press the button repeatedly until you reach the ThermoControl act-
ive operating status. Relevant pathogens will then be deactivated in
the filter by MieleThermoControl. After MieleThermoControl, the fan
keeps running automatically in order to cool down the filter safely,
after which the appliance switches back to the Ready for operation
operating status.
Displaying oper-
ating values
The operating values of the air purifier can be displayed via the Oper-
ating values displaymenu.
Press and hold the button for more than 3seconds.
1245
523
V01.1
14:28:00
Operating values display
Operating hours
Time to filter change
Miele
Mon09.11.2020
PAC 1080
h
h
The Operating values displaymenu is now displayed.
25
22
34
14:28:00
Operating values display
Filter saturation
Room temp.:
ThermoControl temp.
Mon09.11.2020
%
°C
°C
Press the or button briefly to scroll through the pages of the
Operating values displaymenu.
To exit the operating values display, briefly press the and but-
tons at the same time (<1sec) or wait 10seconds.
Deactivating the
keypad lock
If the display lighting is switched off, the keypad lock is activated. You
can deactivate the keypad lock by holding down the and but-
tons for at least 3seconds.
If no buttons are pressed within 60seconds of deactivating the
keypad lock, it will be reactivated again automatically.

Using the machine
15
Settings
Settings menu for
“Manual mode”
100
05
Settings
Manual mode
Manual+time mode
CO2 mode
Flow
Off
On
Back
Select option
Flow speed
Please set
Off
On
Back
Select option
Flow
Please set
min
Flow time
%
If settings are configured for the Flow, these settings will automat-
ically be adopted for the other operating modes.
Tip: If you do not wish to make any changes to the Flow, you can exit
the Settings menu quickly by pressing the and buttons briefly at
the same time.
Settings menu for
“Manual+time
mode”
If initial flow is switched on, the air purifier will start the running be-
fore the actual switch-on time: if, for example, the switch-on time is
set for 6:00am with 5minutes of initial flow time, the air purifier will
start at 5:55am.
After the switch-off time, MieleThermoControl is started with a run-
ning time of 20minutes. This is followed by a 10-minute fan run-on
phase.
100
05
Settings
Manual mode
Manual+time mode
CO2 mode
Manual+time mode
Manual+time mode
Manual+time mode
Individual day setting
Individual day setting
Individual day setting
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
Flow
Flow
Flow
Flow
Flow
On Monday
Off Monday
On Tuesday
Please set
Please set
Please set
Please set
On Mon–Fri
Off Mon–Fri
On Sat–Sun
Back Back
Back
Off
Off
On
On
Select option
Select option
Flow speed
min
%
Flow time
If settings are configured, these settings will automatically be adop-
ted for the other operating modes.
- If you do not wish to make any changes, you can exit the Settings
menu quickly by pressing the and buttons briefly at the same
time.

Using the machine
16
- If you do not want to set a separate switch-on time and switch-off
time for each day, you can set the times for the whole week quickly
via Mon–Fri/Sat+Sun. If the switch-on time and switch-off time are
set to 00:00, the appliance will not switch on on the selected day.
Settings menu for
“CO2 mode”
80
100
05
100%
05
Settings
Manual+time mode
CO2 mode
CO2+time mode
CO2 mode
CO2 mode
Manual+time mode
Flow
Flow
Flow
Flow
Flow
Intensive circulation
Intensive circulation
Intensive circulation
Intensive circulation
Intensive circulation
Room size
Room size
Room size
Please set
Please set
Please set
Please set
Please set
Off
Off
Off
Off
On
On
On
On
Back
Back
Back
Select option
Select option
Select option
Select option
Select option
Intensive circ. speed
Intensive circ. time
Flow speed
Sensitivity
Flow time
High
Medium
Low
%
min
min
m²
The Sensitivity sub-menu is used to set the sensitivity with which the
controls respond to open windows when activating intensive circula-
tion.
When High is selected, intensive circulation is activated more
quickly. When Low is selected, it takes longer for intensive circula-
tion to be activated when a window is open.
If settings are configured, these settings will automatically be adop-
ted for the other operating modes.
Tip: If you do not wish to make any changes to the initial flow, you
can exit the Settings menu quickly by pressing the and buttons
briefly at the same time.

Using the machine
17
Settings menu for
“CO2+time mode” If initial flow is switched on, the air purifier will start the running be-
fore the actual switch-on time: if, for example, the switch-on time is
set for 6:00am with 5minutes of initial flow time, the air purifier will
start at 5:55am.
After the switch-off time, MieleThermoControl is started with a run-
ning time of 20minutes. This is followed by a 10-minute fan run-on
phase.
100
05
80
07:00
17:00
07:00
100
05
Settings
CO2 mode
CO2+time mode
CO2+time mode
CO2+time mode
CO2+time mode
Modus CO2+Uhr
CO2+time mode
Language
Room size
Room size
Room size
Individual day setting
Individual day setting
Individual day setting
Individual day setting
Flow
Flow
Flow
Flow
Flow
Off
Off
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
Mon–Fri/Sat+Sun
On
On
Back
Back
Back
Select option
Select option
Select option
Flow speed
Please set
Please set
Please set
Please set
Please set
Please set
Please set
Flow time
Intensive circ. time
On Monday
Off Monday
On Tuesday
On Mon–Fri
Off Mon–Fri
On Sat–Sun
Intensive circ. speed
Sensitivity
High
Medium
Low
Intensive circulation
Intensive circulation
min
m²
min
%
%
The Sensitivity sub-menu is used to set the sensitivity with which the
controls respond to open windows when activating intensive circula-
tion.
When High is selected, intensive circulation is activated more
quickly. When Low is selected, it takes longer for intensive circula-
tion to be activated when a window is open.
If settings are configured, these settings will automatically be adop-
ted for the other operating modes.

Using the machine
18
Tip: If you do not wish to make any changes to the initial flow, you
can exit the Settings menu quickly by pressing the and buttons
briefly at the same time.
Settings menu for
“Language/Time/
Date/Service”
10.12.2020
07:46
Settings
Settings
Settings
Settings
CO2+time mode
Language
Time
English
Please set
Language
Language
Time
Time
Time
Please set
Service
Change filter
Date
Date
Date
Date
Service *
*For the Miele Customer Service Department only
Settings menu for
“Change filter/
Factory defaults/
Display contrast”
20
Settings
Settings
Settings
Service
Change filter
Change filter
Change filter
Factory defaults
Factory defaults
Factory defaults
Display contrast
Display contrast
Display contrast
Reset filter time
Reset filter time
Back
Back
Back
Back
Reset to factory defaults
No
No
Yes
Yes
Please set
Select option Select option
Select option

Installation
19
Transport and installation
Only personnel who have received instruction from the supervisor
may transport and install the air purifier.
Risk of tipping during unsecured transport.
There is a risk that the air purifier may tip over in the event of unse-
cured transport with incorrect transport equipment or lifting equip-
ment.
The air purifier may only be transported by personnel who have re-
ceived appropriate instruction.
The air purifier must be installed upright on a firm and secure surface.
The castors on the bottom of the air purifier can be used to move it
around the room. When moving the air purifier, make sure that the
surface is level and the air purifier is secured to prevent it tipping
over. To prevent damage and accidents, always remove the plug from
the socket before moving the air purifier.
Risk of tripping if the appliance is moved without disconnecting
the mains connection cable.
If the air purifier is moved without disconnecting the mains connec-
tion cable, there is a risk that someone will trip over the tensioned
cable and sustain an injury. This may also damage the mains con-
nection cable.
Remove the plug from the socket before moving the air purifier.
Risk of tipping if care is not taken when moving.
Uneven floors or objects on the floor can cause the air purifier to tip
over.
When moving the air purifier, make sure that the surface is level
and the air purifier is secured to prevent it tipping over.
Always move the air purifier in a forward direction to ensure that it
cannot tip towards you.
Make sure you do not roll the appliance over the mains connection
cable.

Installation
20
Mounting the adjustable feet
The air purifier is supplied with 4adjustable feet which can be
mounted on the bottom of the plinth in order to stabilise the appli-
ance. At least 2people are required to fit the adjustable feet.
To fit the adjustable feet to the bottom of the air purifier, tilt the air
purifier sideways or lay the appliance down completely. Make sure
you do not lay the air purifier on the mains connection cable.
Risk of crushing if the air purifier tips over.
When tilting or laying down the air purifier, there is a risk that body
parts will be crushed and/or trapped accidentally.
Work to fit the adjustable feet must be carried out by at least
2people.
Take great care when tilting the appliance.
Screw the 4adjustable feet in a clockwise direction into the desig-
nated holes on the bottom of the air purifier.
Risk of trapping if care is not taken when fitting the feet.
When fitting the adjustable feet, there is a risk that fingers will be
trapped accidentally.
Take care not to trap your fingers when fitting the adjustable feet.
Other manuals for PAC 1045
3
This manual suits for next models
2
Table of contents
Other Miele Air Cleaner manuals