Mijar MINIBOY VE User manual

BEDIENUNGSANLEITUNG
englisch
Wasserenthärter
Mini Boy VE
KBS Gastrotechnik GmbH - Johannes-Kepler-Str. 14 - 55129 Mainz
www.kbs-gastrotechnik.de
Stand November 2018

1
| MIJAR WATER TREATMENT |
| Azotowa 15b | 41- Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
U
US
SE
ER
R
M
MA
AN
NU
UA
AL
L
AUTOMATED WATER SOFTENER STATION
MINIBOY VE
Installer Stamp
Date of Installation ……………………………………..
Serial Number ………………………………………….
Please read the operating manual before startup!
The manufacturer is not responsible for malfunctions caused by faulty operation and
failure to comply with the provisions of this documentation.
Store for later use! This operating manual is an integral part of the device.

2
| MIJAR WATER TREATMENT |
| Azotowa 15b | 41- Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
Table of contents
General instructions..................................................................................................................................3
Transportation and packaging ................................................................................................................. 3
Liability Exclusion .................................................................................................................................. 3
How it works ...........................................................................................................................................4
Standards, provisions and statutory regulations ......................................................................................4
1. Description of the device ....................................................................................................................4
1.1 System structure ...........................................................................................................................4
1.2 Technical description ..................................................................................................................5
1.3 Control function ............................................................................................................................6
2. Preparation for installation .................................................................................................................6
2.1 Installation preparation plan .........................................................................................................6
2.2 Dismantling and utilization .......................................................................................................... 6
3. Installation ..........................................................................................................................................7
3.1. Parameter enquiry ........................................................................................................................8
3.2. Programming device short version for the installer ..................................................................8
3.3. Parameter settings programming the steering valve...................................................................9
4. Troubleshooting ............................................................................................................................... 11
5. Spare parts ....................................................................................................................................... 17
6. Product card ..................................................................................................................................... 18

3
| MIJAR WATER TREATMENT |
| Azotowa 15b | 41- Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
General instructions
1. The relevant installation and operation instructions contained in this manual must be read prior to
the installation and operation of this device.
2. The manufacturer will not bear responsibility in case of improper use and incorrect operation of
the device.
3. The system is used only for removing unwanted mineral substances, which accumulate as lime
scale (Calcium and Magnesium). This device is a part of the system protection.
4. It is forbidden to make change in the system without consultation with the manufacturer. The
manufacturer will not bear responsibility in case of any damage caused by this type of
modification.
5. The temperature in the device operating room must be at least C
6. The general regulations and provisions as well as provisions concerning accident prevention
must be observed at the installation location of the device.
7. The installation location of the device must be secured from any damage caused by water (e.g. by
the existing floor drain). The manufacturer is not responsible for any damage caused by water.
8. The appliance in which the filter is used must be free of limescale and gypsum deposits prior to
installation.
9. Do not assemble near sources of heat and open flames.
10. Protect the filter system from mechanical damage.
11. Installation and maintenance of the filter system may only be carried out by trained and authorised
personnel.
12. For cleaning do not use any abrasive chemicals, cleaning solutions or astringent cleaning agents
13. The proper name and serial number of the device must be provided with any enquiries and
ordering of spare parts. Only then an effective and quick reply or order implementation is ensured.
Transportation and packaging
Prior to shipment our systems are carefully packed and controlled.
Damage during transportation cannot be excluded in case of shipment by a shipping company.
It is necessary therefore to check the package at receipt of the product.
1. Check the completeness of the delivery based on the delivery receipt.
2. In case of damaged packaging: perform a visual inspection of the goods and record conclusions in
the shipping documentation provided by the shipping company. Make photographic
documentation of the damaged package and the device. In the shipping documentation place an
annotation of possible claiming of hidden damages, which may be revealed after start-up.
Immediately contact the shipping company because otherwise the shipping insurance will not be
available. Save the package for the purpose of any later inspections by the shipping or insurance
company.
3. In case of returning the package, it must be packed in a way to be protected against any
mechanical damage.
4. Drain water from the system prior to the shipment. This will help reduce shipping costs. It will
also prevent the packaging from damage due to potential water leakage.
at least 24 hours before it is commissioned at the stated ambient temperatures for operation.
Liability Exclusion
Installation must be performed precisely in accordance with the instructions in this manual.
Manufacturer shall not be held liable for any damage, including subsequent damage, arising from the
incorrect installation or use of the product.

4
| MIJAR WATER TREATMENT |
| Azotowa 15b | 41- Poland | Tel./fax. 32 2899674 | email: export@mijar.eu | www.mijar.eu |
How it works
Hard water contains the combination of calcium (Ca), magnesium (Mg) and iron (Fe). The softening process
serves the removal of the positively charged ions by means of ion-exchanged resin. When the ion-exchanged
resin loses its effectiveness it is regenerated by the reagent.
Regeneration:
The regeneration is based on rinsing the deposits using the tablet salt solution and rinsing out the absorbed
calcium and magnesium ions into the sewage.
Regeneration takes place automatically in an intelligent logical cycle. On the basis of the water use from the last
7 days the system itself chooses the day of regeneration at the pre-set time. During regeneration (60 min), hard
water is available.
Regeneration process consist of 4 cycles:
1. Backwashing ( 5 min.)
2. Brine and Slow Rinses ( 50 min)
3. Refilling ( 35 sec.) about 2,8 liter
4. Fast Rinsing ( 5 min)
Standards, provisions and statutory regulations
1. Water supplying the device must comply with the requirements of the utility water use regulation.
2. Parts that are in contact with treated water must be made of material resistant to treated water,
3. In the room for the water treatment floor drainage must be installed. The purchaser is responsible to
ensure the drainage.
4. Maximum temperature of the supply water is
1. Description of the device
1.1. System structure
The system of water purification type MiniBoy VE is a device of high quality and precision.
Properly installed and maintained guarantees infallible functioning for many years.
The water softener station of small efficiency type MiniBoy VE is used where the water flow does not
exceed 30l/m.
System structure:
1. Water softener Type : MiniBoy VE
2. Drain hose ½”
1.2. Technical description
Quantity of softened water for 10odh /regeneration
[liters ]
1950
Salt Consumption
[kg]
1,0
Flow Rate
[l/min]
1,8-30
Operating pressure
[bar]
2,0 - 6,0
Time of regeneration
[min]
60,5
Connections
[cal]
Height
[mm]
480
Depth
[mm]
440
Width
[mm]
270
Maximum water temperature
[0C]
40
Salt storage capacity
[kg]
24
Table of contents
Other Mijar Water Dispenser manuals
Popular Water Dispenser manuals by other brands

IBC Water
IBC Water AST0715MP-960 Installation & operating instructions

Lancaster Water Treatment
Lancaster Water Treatment X FACTOR LX15 Series Installation, operating and service manual

Elkay
Elkay EMABF8 Series Installation & use manual

Oasis
Oasis Osmosis Home installation manual

Monarch Water
Monarch Water ULTIMATE MINI AQUA HE install guide

Haier
Haier HLM-109B instruction manual