MIKRODEV RTU300 User manual

RTU300
HARDWARE MANUAL
•RTU301
•RTU310
•RTU320
•RTU330
•RTU340
RTU Series
06 / 2023
MIKRODEV_HM_RTU300_EN
v1.5

1
RTU300 SERIES –HARDWARE MANUAL
CONTENTS
FIGURES LIST.................................................................................................................................... 2
Preface............................................................................................................................................. 3
About Mikrodev............................................................................................................................... 4
WARNING!....................................................................................................................................... 5
Mounting Information..................................................................................................................... 6
1RTU300 GENERAL INFORMATION ...................................................................... 7
1.1 GA1 Board Type Physical Interface .............................................................. 7
1.2 GA2 Board Type Physical Interface .............................................................. 8
1.3 GA4 Board Type Physical Interface .............................................................. 9
1.4 GA5 Board Type Physical Interface .............................................................10
1.5 GA6 Board Type Physical Interface .............................................................11
1.6 GA7 Board Type Physical Interface .............................................................12
1.7 General Device Specifications ....................................................................13
1.8 Power Connection Diagram........................................................................14
1.9 Digital Inputs...........................................................................................15
1.10 Digital Outputs.........................................................................................16
1.11 Relay Outputs ..........................................................................................17
1.12 Analog Inputs ..........................................................................................18
1.13 Analog Outputs ........................................................................................19
1.14 Serial Ports..............................................................................................20

2
RTU300 SERIES –HARDWARE MANUAL
FIGURES LIST
Figure 1 DIN Rail Mounting ..................................................................................... 6
Figure 2 Expansion Module Mounting ....................................................................... 6
Figure 3 GA1 Board Type Connector and Physical Interface......................................... 7
Figure 4 GA2 Connector and Physical Interface.......................................................... 8
Figure 5 GA4 Board Type Connector and Physical Interface......................................... 9
Figure 6 GA5 Board Type Connector and Physical Interface........................................10
Figure 7 GA6 Board Type Connector and Physical Interface........................................11
Figure 8 GA7 Board Type Connector and Physical Interface........................................12
Figure 9 RTU300 Power Connection Diagram............................................................14
Figure 10 RTU300 Digital Input Connection Diagram .................................................15
Figure 11 RTU300 Digital Output Connection Diagram ...............................................16
Figure 12 RTU300 Relay Connection Diagram...........................................................17
Figure 13 RTU300 Analog Input Connection Diagram ................................................18
Figure 14 RTU300 Analog Output Connection Diagram ..............................................19
Figure 15 RTU300 RS485 Serial Port Connection Diagram..........................................20
Figure 16 RTU300 RS232 Serial Port Connection Diagram..........................................21

3
RTU300 SERIES –HARDWARE MANUAL
Preface
Mikrodev RTU300 series RTUs can monitor and control Intelligent Electrical Devices
(protection relays, reclosing cutters, energy and quality analyzers ... etc) via industry
standard protocols like IEC 61850, Modbus TCP and Modbus RTU. Thay can also
communicate with SCADA or control center software via IEC 60870, DNP3 and MODBUS
TCP protocols. With its easy, flexible and fast programming capabilities and expandable
I/O capability up to 1024 points, Mikrodev RTU products are preferred for electrical
applications. Mikrodev RTU300 Series RTUs are programmed mainly using Function Block
Diagram - FBD language which is defined in IEC 61131-3 standard. Thanks to programming
with FBD language, you can develop applications easily and quickly with drag and drop
logic.
Please follow our website www.mikrodev.com for the up to date version of the document.

4
RTU300 SERIES –HARDWARE MANUAL
About Mikrodev
Since 2006, MIKRODEV has been developing and manufacturing industrial control and
communication products. MIKRODEV serves the system integrators in the public and
private sector, OEM and end users. Our products are manufactured complying with the
quality standards required by the industrial automation industry and the quality of our
products are proved on the field for many years MIKRODEV is one of the few companies in
the world that has its own designed IEC 61131- 3 compliant library for its programmable
logic control devices. In addition, the open, flexible, programmable SCADA solution
developed by MIKRODEV is also available to customers. MIKRODEV products' performance
and wide range of applications make them possible for customers to achieve faster,
simplified and cost-effective results.

5
RTU300 SERIES –HARDWARE MANUAL
WARNING!
✓Please take care of the following issues when using Mikrodev devices.
✓Since the unit operates with 24 VDC (12-36 VDC) voltage, you should take care of
the voltage level that the unit is connected to. If a voltage above this voltage level
is applied, the device may be damaged and may be out of warranty.
✓Make sure that the energy connection of your device is connected to the ground or
to a properly grounded terminal.
✓Make sure that the environment in which your device is being used is free of
moisture, electric shock, vibration and dust.
✓Pay attention to the supply voltage and the connections of the product. Mikrodev is
not responsible for any issues due to power failure since there is no auxiliary supply
(UPS) on the device.
✓The fuse to be used must be a FF super fast type and current limit value 1A.
✓Do not use the device under conditions other than the environmental conditions
specified in the "Electrical Specifications" section (humidity, dust, liquid and
temperature, etc.)
✓Removing the warranty label on the product or removing the protective case will void
the warranty.
✓Products that are damaged, boxes have been changed and other brand labels are
affixed are not covered by the warranty.
✓The appliance must not be cleaned with solvents (thinner, benzine, acid etc.) or with
abrasive cleaning agents.
✓Only dry cloth should be used when cleaning the appliance.
✓Do not open the device by removing the case of the appliance, do not interfere with
the electronic components and circuits. There is no user-replaceable part inside the
device.
✓If there is a problem or malfunction on your device, it should only be repaired by
an authorized service. Installation and electrical connections must be made by
technical personnel in accordance with the instructions in the operating manual.
Failure to comply with these rules may result in death, serious injury or property
damage

6
RTU300 SERIES –HARDWARE MANUAL
Mounting Information
DIN Rail Mounting
First, the upper part of the device is mounted on the DIN rail. Then, with the help of the
springs behind the device, when a lightly force is applied to the lower part, the device
locates into the DIN rail easily and the montage is completed (See Figure 1).
Figure 1 DIN Rail Mounting
Expansion Installation
Assembly between RTU300 series RTU products and XIO211 series expansion modules is
carried out by sliding the tabs over the rail so that the tabs overlap each other
Figure 2 Expansion Module Mounting

7
RTU300 SERIES –HARDWARE MANUAL
1RTU300 GENERAL INFORMATION
1.1 GA1 Board Type Physical Interface
Figure 3 GA1 Board Type Connector and Physical Interface
1
Digital Input GND Connection
16
Device Power (V+) Connection
2
Analog Output Connections
17
Device Power (V-) Connection
3
Analog GND Connection
18
Ethernet Port
4
Analog Input Connection
19
USB Port
5
RS485 Connections
20
Relay Status Information LED
6
RS232 GND Connections
21
Digital Output Status Information LED
7
RS232 TX-RX Connections
22
Digital Input Status Information LED
8
N/A
23
System Power LED
9
N/A
24
System Running LED
10
Relay Connections
25
System Error LED
11
CANBUS Connection
26
Protocol Data Transfer LED
12
Digital Input Connections
27
Antenna Connection
13
Digital Output Connections
28
SIM Card Slot
14
Digital Output Supply(Vin) Connection
29
SD Card Slot
15
Digital Output GND Connection

8
RTU300 SERIES –HARDWARE MANUAL
1.2 GA2 Board Type Physical Interface
Figure 4 GA2 Connector and Physical Interface
1
Digital Input GND Connection
14
Device Power (V+) Connection
2
Analog Input Connection
15
Device Power (V-) Connection
3
Analog Input GND Connection
16
Ethernet Port
4
RS485 GND Connections
17
USB Port
5
RS485 Port 1 Connections
18
Digital Output Status Information LED
6
RS485 Port 2 Connections
19
Digital Input Status Information LED
7
RS422 Connections
20
System Power LED
8
RS232 TX-RX Connection
21
System Running LED
9
CANBUS Connection
22
System Error LED
10
Digital Input Connections
23
Protocol Data Transfer LED
11
Digital Output Connections
24
Antenna Connection
12
Digital Output Supply(Vin) Connection
25
SIM Card Slot
13
Digital Output GND Connection
26
SD Card Slot

9
RTU300 SERIES –HARDWARE MANUAL
1.3 GA4 Board Type Physical Interface
Figure 5 GA4 Board Type Connector and Physical Interface
1
Digital Input GND Connection
16
Device Power (V+) Connection
2
Analog Output Connections
17
Device Power (V-) Connection
3
Analog GND Connection
18
Ethernet Port
4
Analog Input Connection
19
USB Port
5
RS485 Connections
20
Relay Status Information LED
6
N/A
21
Digital Output Status Information LED
7
RS485(2) Connections
22
Digital Input Status Information LED
8
N/A
23
System Power LED
9
N/A
24
System Running LED
10
Relay Connections
25
System Error LED
11
CANBUS Connection
26
Protocol Data Transfer LED
12
Digital Input Connections
27
Antenna Connection
13
Digital Output Connections
28
SIM Card Slot
14
Digital Output Supply(Vin) Connection
29
SD Card Slot
15
Digital Output GND Connection

10
RTU300 SERIES –HARDWARE MANUAL
1.4 GA5 Board Type Physical Interface
Figure 6 GA5 Board Type Connector and Physical Interface
1
Digital Input GND Connection
16
Device Power (V+) Connection
2
N/A
17
Device Power (V-) Connection
3
N/A
18
Ethernet Port
4
N/A
19
USB Port
5
RS485 Connections
20
Relay Status Information LED
6
RS232 GND Connections
21
Digital Output Status Information LED
7
RS232 TX-RX Connections
22
Digital Input Status Information LED
8
N/A
23
System Power LED
9
N/A
24
System Running LED
10
Relay Connections
25
System Error LED
11
CANBUS Connection
26
Protocol Data Transfer LED
12
Digital Input Connections
27
Antenna Connection
13
Digital Output Connections
28
SIM Card Slot
14
Digital Output Supply(Vin) Connection
29
SD Card Slot
15
Digital Output GND Connection

11
RTU300 SERIES –HARDWARE MANUAL
1.5 GA6 Board Type Physical Interface
Figure 7 GA6 Board Type Connector and Physical Interface
1
Digital Input GND Connection
16
Device Power (V+) Connection
2
N/A
17
Device Power (V-) Connection
3
Analog GND Connection
18
Ethernet Port
4
Analog Input Connection
19
USB Port
5
RS485 Connections
20
N/A
6
RS232 GND Connections
21
Digital Output Status Information LED
7
RS232 TX-RX Connections
22
Digital Input Status Information LED
8
N/A
23
System Power LED
9
N/A
24
System Running LED
10
N/A
25
System Error LED
11
CANBUS Connection
26
Protocol Data Transfer LED
12
Digital Input Connections
27
Antenna Connection
13
Digital Output Connections
28
SIM Card Slot
14
Digital Output Supply(Vin) Connection
29
SD Card Slot
15
Digital Output GND Connection

12
RTU300 SERIES –HARDWARE MANUAL
1.6 GA7 Board Type Physical Interface
Figure 8 GA7 Board Type Connector and Physical Interface
1
Digital Input GND Connection
16
Device Power (V+) Connection
2
N/A
17
Device Power (V-) Connection
3
Analog GND Connection
18
Ethernet Port
4
Analog Input Connection
19
USB Port
5
RS485 Connections
20
N/A
6
N/A
21
Digital Output Status Information LED
7
RS485(2) Connections
22
Digital Input Status Information LED
8
N/A
23
System Power LED
9
N/A
24
System Running LED
10
N/A
25
System Error LED
11
CANBUS Connection
26
Protocol Data Transfer LED
12
Digital Input Connections
27
Antenna Connection
13
Digital Output Connections
28
SIM Card Slot
14
Digital Output Supply(Vin) Connection
29
SD Card Slot
15
Digital Output GND Connection

13
RTU300 SERIES –HARDWARE MANUAL
1.7 General Device Specifications
SPECIFICATION
ITEM
DESCRIPTION
Processor
Processor
Architecture
ARM Cortex M4
Processor Internal
RAM
196 KB
CPU Speed
168 MHz
Adressing
Architecture
Little Endian Addressing
Electrical
Supply
24 VDC (12-36VDC)
Power
<13W @ 24V DC
Real Time Clock
Integrated
Input / Output
Board Type
GA1, GA4
GA2
GA5
GA6, GA7
Digital Input
16 Channel,
PNP
16 Ch.
16 Ch.
16 Ch.
Digital Output*
8 Channel,
Max.
0.5A@24VDC
per Channel,
PNP
8 Ch.
8 Ch.
8 Ch.
Analog Input
4 Channel, 0-
20 mA, 4-20
mA
8 Ch.
4 Ch.
Analog Output
2 Channel, 0-
20 mA, 4-20
mA
Relay Output
4 Channel,
Max.
3A@30VDC
- 5A@250VAC
per Channel
4 Ch.
Enviromental
Conditions
Operating
Temperature
-25…+75 C
Storage
Temperature
-30…+85 C
Humidity
5…95 RH
Operating Altitude
0…2000 m
Memory
SD Card
Support**
Micro SD
Retentive Memory
4 KB, 128 Block/Register
Max Event Log
20000
Program Memory
4 MBit
Communication
Ports
Board Type
GA1, GA5,
GA6
GA2
GA4, GA7
Ethernet Port
10/100 Mbps
10/100
Mbps
10/100 Mbps

14
RTU300 SERIES –HARDWARE MANUAL
RS485
1 Port, ESD
Protection, 8
kV Direct, 25
kV Air
Discharge
2 Port,
ESD
Protection
, 8 kV
Direct, 25
kV Air
Discharge
or 1 port
RS485
and 1 port
RS422
2 Port, ESD
Protection, 8 kV
Direct, 25 kV Air
Discharge
RS232
1 Port
1 Port
(with flow
control)
Wireless
Communication
GSM/LTE**
LTE Modem
Expansion
Capacity
DIN Rail Type-
CANBUS
Expansion
Up to 1024 I/O Points
*The digital outputs are 125 mA per channel in production prior to serial number 761800.
**Optional selection
1.8 Power Connection Diagram
1.8.1 Supply Connection
Board Type:
GA1, GA2, GA4, GA5, GA6, GA7
Supply:
12-36 VDC, Protected
Power:
<13 W
Figure 9 RTU300 Power Connection Diagram

15
RTU300 SERIES –HARDWARE MANUAL
1.9 Digital Inputs
Board Type:
GA1, GA2, GA4, GA5, GA6, GA7
Module Input:
16 Channel, PNP
Voltage Range:
0-36V DC
ON Voltage Level:
12-36V DC
OFF Voltage Level:
0-10V DC
Input Impedance:
>2M
Isolation:
Optical
OFF to ON Response:
20 us
ON to OFF Response:
90 us
Figure 10 RTU300 Digital Input Connection Diagram

16
RTU300 SERIES –HARDWARE MANUAL
1.10 Digital Outputs
Board Type:
GA1, GA2, GA4, GA5, GA6, GA7
Module Output:
8 Channel, Mosfet Output
Module Output Type:
PNP Transistor
Voltage Range:
12-36V DC
Max. Output Current:
0.5A@24VDC per Channel
Isolation:
Optical
Figure 11 RTU300 Digital Output Connection Diagram

17
RTU300 SERIES –HARDWARE MANUAL
1.11 Relay Outputs
Board Type:
GA1, GA4, GA5
Module Output:
4 Channel
Relay Contact Outputs:
NO(Normally Open) Contact
Contact Max. Current:
3A@30VDC –5A@250VAC per Channel
Isolation
Dry Contact
Figure 12 RTU300 Relay Connection Diagram

18
RTU300 SERIES –HARDWARE MANUAL
1.12 Analog Inputs
Board Type:
GA1, GA4
GA2
GA6, GA7
Module Input:
4 Channel
8 Channel
4 Channel
Analog Input Type:
0-20 mA, 4-20 mA
0-20 mA, 4-20 mA
0-20 mA, 4-20 mA
Analog Input Resolution:
16 Bit
16 Bit
12 Bit
Analog Input Precision:
%1 Precision
%1 Precision
%1 Precision
Common Input GND:
1 GND (4 Point /
Common)
2 GND (8 Point /
Common)
1 GND (4 Point /
Common)
Figure 13 RTU300 Analog Input Connection Diagram

19
RTU300 SERIES –HARDWARE MANUAL
1.13 Analog Outputs
Board Type:
GA1, GA4
Module Output:
2 Channel
Analog Output Type:
0-20 mA, 4-20 mA
Analog Output Resolution:
12 Bit
Current Output Precision:
%1 Precision
Common Output GND:
1 GND (2 Point / Common)
Figure 14 RTU300 Analog Output Connection Diagram
This manual suits for next models
16
Table of contents
Other MIKRODEV Controllers manuals
Popular Controllers manuals by other brands

Digitrax
Digitrax DN166PS quick start guide

ROSSMONT
ROSSMONT Waver Master WR-2CH quick guide

Miller Electric
Miller Electric RFC-23A owner's manual

TREND
TREND IQ23 Series installation instructions

Technibel
Technibel K70D044Z Series installation instructions

Mitsubishi Electric
Mitsubishi Electric MELSEC-Q/L Programming manual