Milkcan MCL13046 User manual

7 Line Fold Down Clothesline
MCL13046
2 x Wall Brackets
2 x Front Bars
Contents
Your carton should contain the following parts:
2 x Side Arms (assembled)
1 x Front Brace
1 x Accessories Bag
1 x Line Cord
Wall
Bracket Line Cord
Telescopic
Strut
Side Arm
Front Bar
Front Brace
Line
Tensioner
- Tape Measure
- Timber or Masonry Drill Bits
- Pencil
Required
Tools
- Drill / Hammer drill (ideal)
- Spanner
Optional
- Spirit Level
- Hack Saw (if shortening width)
The recommended mounting height of the top slotted hole in the wall bracket is: USERS HEIGHT + 10cm. Minimum height is 160cm.
Choosing a Suitable Location
Installation and Assembly
If you are using a Milkcan Ground Mount Kit, skip steps 1 & 2 and refer to instructions inside the ground mount kit packaging.
1. Mark position of wall brackets to an overall width of 240cm between centres. If your required width is less than 240cm, please refer to
Reducing the Overall Width below.
3.0
www.milkcan.com.au
(03) 9464 6964
56 Northgate Drive,
Thomastown VIC 3043
20cm
20cm
Reducing the Overall Width
If your available space doesn’t allow the full 240cm
width, you can reduce the width of your Clothesline as
follows:
- For this example, we are assuming your required
overall width is 200cm. This is a total reduction of
40cm.
- Cut half from each side of the 2 x cross bar
segments i.e. 40 / 2 = 20cm each side
The cuts will be
covered by the
cross brace

3.0
Cut the cable tie securing the strut and t the free end to the bottom hole of the wall brackets
using the 60mm Coach bolts and nuts provided.
3. Fit the side arms to the top hole of the wall brackets using 60mm coach bolts provided.
4. Assemble the front bar, pushing the left and
right bars fully into the front brace until they
hit the small indent in the middle of the front
brace.
5. Spread the side arms slightly apart and insert
the assembled front bar into the corners as
shown right.
OU TDOOR P R O D UCTS
LIFTCL I CKL OCK & RELE ASE
User’sUser’s
heightheight
++
10cm10cm
User’s
height
+
10cm
Attach Attach
through through
these holesthese holes
Attach
through
these holes
1. Ensure the Line Tensioner is at the front of the right hand side arm.
Line Cord Installation
2. Start threading the line cord through the left
side arm hole nearest the wall bracket. Tie
off the end as shown right.
CLAMPING LEVER
3. Progressively tighten each line, starting from the rear, working towards the front. Don't over-tighten or you
will distort the side arms.
4. Thread the cord through the Line Tensioner as shown. Lift the clamping lever up before threading the cord.
Push the lever down to clamp the cord.
To Lower Lift the front bar higher until you hear another click from each side. It can now be folded
fully down.
To Raise Slowly lift the front bar until you hear a single click from each strut.
Using your Clothesline
Installation and Assembly (cont...)
- For brick walls, use the M8 (10mm) masonry
anchors provided
- For timber posts, use the M10 coach screws
provided
2. Attach the wall brackets to your brick wall or
timber posts.

Ground Mount Kit
www.milkcan.com.au
(03) 9464 6964
56 Northgate Drive,
Thomastown VIC 3043
MCL13031
1.5
2 x Posts 1 x Cross Brace
2 x Cross Bars 1 x Accessories Bag
Your carton should contain the following parts:
Contents
Required
Tools
- Tape Measure
- Spanner
Optional
(if shortening width)
- Spirit Level
- Hack Saw
The Clothesline and Ground Mount Kit are 240cm wide. If your required width is less than 240cm, please refer to Reducing the
Overall Width below.
Choosing a Suitable Location
The recommended mounting height of the top slotted hole in the wall bracket is: USERS HEIGHT + 10cm. Minimum height is 160cm.
20cm
20cm
- Cut half from each side of the 2 x cross bar
segments i.e. 40 / 2 = 20cm each side
- For this example, we are assuming your required
overall width is 200cm. This is a total reduction of
40cm.
Reducing the Overall Width
If your available space doesn’t allow the full 240cm
width, you can reduce the width of your Clothesline as
follows:
The cuts will be
covered by the
cross brace
Mounting
Post
Cross Brace
Cross Bar

Cross Brace
Wall Bracket
(from Clothesline)
Cross Bar
Ground
Mount
Post
Long Bolt
Short Bolt
1. Assemble the cross bar. Push the left and right bars fully into
the cross brace until they hit the small indent in the middle.
2. Attach the assembled cross bar and Clothesline wall brackets
to the Ground Mount posts.
Fix into place using the 2 x screws supplied.
3. Before installation we suggest attaching the clothesline
assembled side arms to the wall brackets. Please refer to Step
3 on the clothesline instruction sheet. Don’t attach the
Clothesline front bar or line cord yet, this will be done later.
Assembly
If you are using the Mounting Plate Kit,
continue installation using the
instructions included in your Mounting
Plate Kit packaging.
3. Place the assembled Ground Mount Kit into the holes
you’ve just dug. The cross bar should be 10cm above
the typical users height. The height of the cross bar can
be adjusted by cutting the Mounting Posts down in
height (only cut the end that goes in the ground).
1. In your chosen location, mark two holes on the ground
240cm apart (or your chosen width) for the posts.
Installation
2. Dig the two holes to a depth of 40cm and ll with 5cm
of gravel to allow for drainage.
4. Concrete the Mounting Posts into the holes, checking
the following before and during concreting:-
- Post spacing is 240cm between centres (or your
chosen width).
- Mounting Posts are vertical - check with a spirit level.
- Cross bar is horizontal - check with a spirit level.
5. Clean any excess concrete from the posts with a damp
cloth. Allow the concrete to set for 24 hours before
attaching the Clothesline front bar and line cord.
1.5
40cm40cm
deep holedeep hole
40cm
deep hole
5cm5cm
GravelGravel
5cm
Gravel

Mounting Plate Kit
www.milkcan.com.au
(03) 9464 6964
56 Northgate Drive,
Thomastown VIC 3043
MCL13038
Mounting Plate Installation (Figure 1, 2 & 3)
If your available space is less than this, refer to
Reducing the Overall Width.
- Ground Surface is concrete
Your carton should contain the following parts:
2 x Mounting Plates
6 x Self-drilling Screws
- 7, 11 & 13 line Clothesline and Ground Mount Kit are
240cm wide.
6 x Concrete Bolts
- Wall mounting of the clothesline is not possible and
Ground Mount posts must be used.
Contents
The Mounting Plate Kit is required when:
Choosing a Suitable Location
Check that your chosen location has suitable side
and front clearance. Allow 50cm side clearance and
100cm front clearance.
- 10 line Clothesline and Ground Mount Kit are 220cm
wide.
2. Mark concrete through the 3 x holes on base plate.
Repeat step for the second Mounting Plate.
Note the side with one hole is at the front.
3. Using a hammer drill and 10mm masonry drill bit,
drill all 6 x marked hole positions to a minimum
depth of 80mm. Clean and prepare holes for
installation.
4. Place the Mounting Plates in position and afx with
the concrete bolts provided. Repeat for the second
Mounting Plate.
1. Position Mounting Plates to match the same centre
spacing as your Clothesline and Ground Mount Kit.
Reducing the Overall Width
If your available space doesn’t allow the full
width, you can reduce the width of your
Clothesline and Ground Mount Kit as follows:
1. For the Clothesline, refer to the Clothesline
instruction sheet.
2. For the Ground Mount Kit, refer to the Ground
Mount Kit instruction sheet.
6. Insert the Ground Mount posts into the
Mounting Plates you just installed and secure
with the self-drilling screws through the holes
in the Mounting Plate posts.
Note if the ground is not level you will have to
adjust the post heights accordingly i.e. one post
will have to be longer or shorter than the other,
depending on the slope of the ground
5. The Ground Mount posts will need to be cut
down in height when they are installed into the
Mounting Plates. The amount they are cut
down depends on the users height, we
recommend that the cross bar be at the user’s
height + 10cm.
Use the chart below to see how much the posts
should be cut.
150
155
165
170
175
160
180
Users Height
(cm)
Cut bottom of
Ground Mount
post by (cm)
55
50
45
60
40
30
35
2.0

Figure 3
Figure 1
If Clothesline and Ground Mount Kit width
has been reduced, adjust accordingly.
Figure 2
STEP 2 STEP 3 STEP 4
STEP 1
STEP 6
x 3
FRONT
FRONT
10cm10cm10cm
220cm
10 line
240cm
7,11 & 13 line
2.0
Table of contents
Other Milkcan Household Appliance manuals
Popular Household Appliance manuals by other brands

Mailbox Post Solutions
Mailbox Post Solutions Return-to-Center SwingAway Mailbox Support installation instructions

ARESA
ARESA AR-4101 instruction manual

Pella
Pella 801U0102 installation instructions

Beper
Beper 50.245 use instructions

Pifco
Pifco PE151 instruction manual

MELINERA
MELINERA KH 4160 - 3 operating instructions