MOUNTING THE VIDEO CAMERA
• Beforemountingcamera,besurethatColumnClampHandleistightandthe
wheels are locked.
• PlacethePedestalonastableandflatfloor.
• MountyourFluidHeadonthe100mmbowl.Whenusinga75mmHeada#378
100/75 bowl adaptor is available from your Miller dealer.
• MountthecameratotheFluidHeadusingthequickreleasecameraplate.
Apply all appropriate accessories to the camera up to the maximum of 30kg
total load (camera, head & accessories together). Refer to the Operator’s
Manual of the Fluid Head.
• IfnecessaryusethePumptoincreasepressuretotheairsystemorusethe
Set Knob to decrease the pressure. Use the complete vertical stroke of the
Pedestal Column to test what is the ideal situation.
• Iftoomuchairpressureisappliedthesafetyvalvewillopenandairwill
escape from the system to prevent it from being overloaded.
Fig 11. Fig 12.
LOW SET-UP ON DOLLY (Fig 11.)
• RemovethethreelockingscrewsthatholdtheBowlUnitontheinsidecolumn
using the supplied hexagon key.
• TakeofftheBowlUnitandlayitaside.
• Removethethreelockingscrewsthatholdthecolumninthebasepieceusing
the supplied hexagon key.
• TakeofftheColumnwithspiderandlayitaside.
• Mount,ifnecessarytheextensionyouneedusingthesamehexagonkey.Fix
them firmly but do not use too much force for there is a chance of damaging
the tool or the screws.
• TaketheBowlunitandmountitontopoftheextensionordirectlytotheBase
Piece of the Dolly.
• AspeciallowsetupispossibleusingonlytheBowlunit,placingitonitsrub-
ber feet on the ground or a table (Fig 12.).
SET-UP (CONT)