5
(4) AC Current
Range Resolution Accuracy
200.0A 0. 1A ±(3% reading + 3 digits)
Frequency Response: 45 ~ 60Hz (Sine Wave)
AC Conversion Type: AC coupled average sensing, RMS indication
Additional Accuracy by Crest Factor (C.F.): Same as ACV.
Max. Crest Factor: Same as ACV.
Adjacent Conductor Influence: < 0.08A/A
Response Time of AC Input: < 2 sec. when the LCD reading is bigger than 1000 digits in each
range.
Overload Protection: AC 400A for 10 second.
(5) Resistance
Range Resolution Accuracy
400.0Ω0.1Ω±(1% reading + 5 digits)
4.000kΩ0.001kΩ
40.00kΩ0.01kΩ
400.0kΩ0.1kΩ
4.000MΩ0.001MΩ
±(1% reading + 2 digits)
40.00MΩ* 0.01MΩ±(2% reading + 5 digits)
* There is a little rolling less then ±50 digits when measuring > 10.00 MΩ.
Open Circuit Voltage: Approx. 0.4V
Response Time: < 1.5 sec.
Overload Protection: AC/DC 600V for 10 second.
(6) Continuity
Range Resolution Accuracy
400.0Ω0.1Ω±(1% reading + 5 digits)
Open Circuit Voltage: Approx. 0.4V
Continuity: Built-in buzzer sounds when measured resistance is less than 30Ωand sounds off
when measured resistance is more than 200Ω, Between 30Ωto 200Ωthe buzzer
maybe sound or off either.
Continuity Indicator: 2.7KHz Tone Buzzer
Response Time of Buzzer: < 500 μsec.
Response Time of LCD reading: < 1.5 sec.
Overload Protection: AC/DC 600V for 10 second.