Minebea MIS-304-P User guide

EN294-1920A
1
MinebeaMitsumi_Inc
Sensing Device Business Unit
DRW. No. EN294-1920A Revised Sept. 24, 2020
Integrated Mold Sensing System MIS-304-P/T
Relay Box Mounting Instructions
For details of how to mount the overall system, see the Integrated Mold Sensing System MIS-202 Instruction Manual
(EN294-1906*).
Relay Box Mounting
The relay box can be mounted either by attaching using the magnets or by bolting using the mounting bolt holes.
When mounting using the magnets, attach to the moving part (platen) of the mold clamping unit. Also make sure the
operating temperature does not exceed 70 °C here.
If the magnets do not provide sufficient magnetic attraction or when attaching to a location where the operating
temperature exceeds 70 °C, the relay box should be bolted to the mold.
Handling Precautions
The relay box ambient temperature should be in the range 0 °C to 70 °C when mounted using the
magnets, and in the range 0 °C to 100 °C when mounted using the bolts.
When mounting using the magnets, check that there is sufficient magnetic attraction. If the
magnetic attraction is insufficient due to the mounting surface conditions, or if the relay box is to be
used for extended periods, mount using the bolts.
Keep credit cards and cash cards away from the magnets, as the magnetism may render them
unusable.
Likewise, the magnets may also cause malfunctions if precision equipment such as PCs and mobile
phones are close by.
Be sure to remove the magnets before mounting the relay box using the bolts. Otherwise, the box
will not make close contact with the mounting surface and will not be securely attached.
Be sure to use bolt mounting when mounting the relay box on a mold.
Mount using two M4 hex socket head bolts each on
either side. (M4 tapped holes must be drilled in the
mounting surface.)
Be sure to remove the magnets when using
bolts to attach the relay box. The magnets can
be removed by removing the screw in the center
of each ma
g
net.
Removing the magnets Bolt mounting
M4 hex socket head bolts ×4
Magnets ×2
Magnet mounting screws ×2

EN294-1920A
2
MinebeaMitsumi_Inc
Sensing Device Business Unit
Installing on Molding Machine (Wiring)
Install the amplifier and relay boxes using the layout shown below as a guide, taking care to prevent
equipment falling off and cables becoming disconnected. Install the relay boxes on the top or side of the mold
or platen to allow the sensors to be connected. The amplifier should be installed on the operating side of the
molding machine where it is accessible by operators and where the LED indicators are visible.
Handling Precautions
Ensure adequate slack in the relay cable and do not clamp the cable close to moving parts to ensure
that the base of the cable is not subjected to any load even when the mold moves.
Install leaving sufficient slack in the relay cable to ensure that the relay cable is not subjected to any
load when the mold moves.
The following minimum bending radii for the cables must be adhered to when installing to prevent
cable disconnection.
Pressure sensor cables:
Clamped sections: 50 mm or greater Movable sections: 50 mm or greater
Temperature sensor cables:
Clamped sections: 70 mm or greater Movable sections: 100 mm or greater
When connecting a relay cable to a relay box, tighten the screws on both sides of the D-sub
connector.
Flexible cable is used for the relay cables, but this is a consumable item, which is subject to
breakage if it is bent excessively. Depending on usage frequency, the cables should be replaced
periodically, or spare cables should be kept on hand.
If a relay box is mounted using the magnets, clamp the relay cable at a point not more than 2 m away
from the relay box. Otherwise, the weight of the cable may pull the relay box away from its mounting
position.
Route the sensor and relay cables to make sure they are not trapped or pulled when the mold
moves. Bundle excess lengths of cable where necessary.
Relay box
* Ensure sufficient slack.
Relay cable
Clamp
Sensor cable

EN294-1920A
3
MinebeaMitsumi_Inc
Sensing Device Business Unit
Exterior Diagram
Units: mm
102.6
15 10
111.6
4.5
7.5 25
40
35.4
4-φ4.5
(40.4)
マグネット
4.5 102.6
111 .6
15 10
7.5 25
40
35.4
4-
φ
4.5
(40.4)
マグネット
(53)
2m (F
A
409-548-2M)
(53)
2m (F
A
409-549-2M)
Magnet Magnet

EN294-1920A
4
MinebeaMitsumi_Inc
Sensing Device Business Unit
General Specifications MIS-304-P
Operating temperature range 0 °C to 70 °C
0 °C to 100 °C (when not using magnets)
Operating humidity range Max. 85 %RH (with no condensation)
Storage temperature range −10 °C to 70 °C
−10 °C to 100 °C (when not using magnets)
Vibration resistance 2 hours at 10 Hz to 55 Hz, double amplitude 1.5 mm,
in X/Y/Z directions respectively
External dimensions (W × H × D) 111.6 mm × 40 mm × 40.4 mm (not including protrusions)
Weight Approx. 190 g (including magnets)
Casing material SUS430
Applicable transducers LSMS-S06 series (20K, 50K, 100K, 200K, 500K, 1T, 3T)
Applicable amplifiers MIS-202-PT, MIS-202-PP
General Specifications MIS-304-T
Operating temperature range 0 °C to 70 °C
0 °C to 100 °C (when not using magnets)
Operating humidity range Max. 85 %RH (with no condensation)
Storage temperature range −10 °C to 70 °C
−10 °C to 100 °C (when not using magnets)
Vibration resistance 2 hours at 10 Hz to 55 Hz, double amplitude 1.5 mm,
in X/Y/Z directions respectively
External dimensions (W × H × D) 111.6 mm × 40 mm × 40.4 mm (not including protrusions)
Weight Approx. 220 g (including magnets)
Casing material SUS430
Applicable transducer K type thermocouple MMTK-01
Applicable amplifier MIS-202-PT
This manual suits for next models
1
Popular Relay manuals by other brands

Emirel
Emirel W 19 quick start guide

ECR International
ECR International ARGO AR Series Installation, operation & maintenance manual

AUDAC
AUDAC ARU20 Series user manual

ARC SUPPRESION TECHNOLOGIES
ARC SUPPRESION TECHNOLOGIES NOsparc MGXDC1F250 user manual

hager
hager EU301 User instructions

ABB
ABB SPAU 341 C user manual