MENU ITEM
DAY SET
NIGHT SET
DIFFERENCE
ALARM
CLOCK
Description
Day humidity setting
Night humidity setting
Variance from day/night humidity setting before pump will engage to mist
Duration of OFF cycle during the day
Low humidity alarm
C
Current Time
Settings Range
1-99%
1-99%
1-20%
1-70%
00:00 - 23:59
Tips:
a) RAPID ADJUST: While setting individual values, press and hold “up arrow” or “down arrow” for faster advancement of settings
b) SAVE & EXIT: When done modifying values press and hold “SET” key for 3 seconds to Save & Exit. Alternatively don't input anything
for 15 seconds and controller will exit automatically saving and displaying the main screen.
Switch between “
o
C and
o
F”: In normal status, pressing up and down arrow key together for 5 seconds switches temperature between
“
o
C and
o
F”.
Q
Quick-ON Function: In normal status, press and hold up arrow key for 5 seconds to active the quick-on function. While pressed the
controller will activate allowing you to quickly bypass any congured settings and manually activate the misting system. Quick ON, does
not affect any settings. When up arrow is released, controller resumes normal operation and misting stops.
Energy-Saving: If there is no key activity on the HT-24 for approximately 10 minutes the LCD backlight automatically turns off. Pressing
any key will reactivate the back light again.
Setup Instructions:
1. Set Current Time (picture A):
Press “
O
” key once to set the clock: When in setup, press “
O
” key to switch between
hour and minute; press up arrow or down arrow to adjust the values when ashing.
2. Configure Humidity settings (picture B):
In normal status, press and hold “SET” for 3 seconds to enter into the setting mode.
a.
a. In the setting mode, “DAY SET” ashes, use up arrow or down arrow to set
required humidity for the day.
b. Press “SET” key once to switch to “NIGHT SET”. When ashing, use up arrow or
down arrow to modify the humidity value for the night.
c. Press “SET” key once to switch to “DIFFERENCE”. When “DIFFERENCE” ashes,
press up arrow or down arrow key to adjust the value. Difference refers to the
allowed humidify drop before the pump will engage.
d
d. Press “SET” key once to switch to “ALARM”. When “ALARM” ashes, use up
arrow or down arrow key to set the ALARM value.
e. Press “SET” key once to save and exit the setting mode.
LL