Assembly Precautions
This Overbed Table utilizes a high-tension spring loaded mech-
anism to raise the table, DO NOT remove #13 Black Screw and
replace with #14 Chrome Screw until table is fully assembled.
DO NOT over tighten bolts, screws or use power tools when
assembling this product.
Important Warnings
Please follow all instructions and warnings to avoid hazardous
situations that can result in property damage and/or patient/
resident/staff/caregiver injury and/or death.
Inspect the product for damage and loose hardware before
each use. DO NOT use the product if it appears to be
damaged or unstable and DO NOT modify the product in any
way.
Intended Use
This product is designed for use as a movable patient/resident
table top surface for reading, eating, or keeping small personal
items such as glasses, telephone, or books within easy reach.
This product is designed for indoor use ONLY within close prox-
imity of skilled caregivers. It is not designed to hold electrical
items (such as televisions, computer monitors, coffee pots, etc.)
and should not be used near open flames and excessive heat.
Maximum weight limitation for this product is 50 lbs (22 kg.);
weight should be evenly distributed over the table top surface
while at the lowest usable height to help maintain a stable con-
dition.
DO NOT overload the product as that could result in breakage,
as well as damage to property and/or serious injury.
Use ONLY as directed for its intended use. This product should
NOT be used: as a sleep surface; as a walker or mobility aid to
assist a person in walking, sitting down or standing up; to
prevent or brace a person’s fall; or to help transport persons or
items.
Parts List
1. Table Top
2. Column Assembly
3. Trip Lever
4. --------
5. Mounting Tube
(Top to Column Assembly)
6. Inner Tube
7. Base
8. Casters with Lock (2 ea)
9. Casters without Lock (2 ea)
10. Bolt Sleeves (2 each)
11. Bolt Plate
12. 3/8 - 15 x 2” Bolts (2 each)
13. Black Screw
14. Chrome Screw (to replace
#13 black screw)
15. Trip Rod 1/4” x 20 1/2”
(inside Column Assembly)
16. Knob
17. Spacer
18. Outer Tube
1. To raise top to desired height, apply light pressure
upward at any point under table.
2. To lower, squeeze trip lever (3) up towards top and
push down at column to desired height. Do not put
pressure on tabletop end that is opposite the column.
Column assembly will lock upon release of trip lever.
3. To tilt, turn Knob (16) counter-clockwise to loosen.
Set to desired angle and then turn knob (16)
clockwise to tighten.
Operating Instructions
16
17
18
13
14
2
7
8
12
11
10
9
6
51
Lifetime Limited
W
arranty
If you have a question about your MOBB Healthcare
device or this warranty, please contact an authorized
MOBB Healthcare dealer.
MOBB Healthcare warrants to the original consumer
purchaser for as long as they own their MOBB product
that it will be free from defects in material and
workmanship under normal use. This warranty is only
applicable to products used in residential applications
within the United States and Canada and is not
transferable to subsequent owners. Should defects in
material or workmanship exist during the applicable
warranty period in any MOBB Healthcare Product,
MOBB Healthcare will elect at its discretion to either
repair or replace the defective material. This warranty
covers only parts and materials of the products supplied
by MOBB Healthcare. Not covered under this warranty
are wear and tear items or abuse of the product in a
manner that was not intended for the product to be
used. This warranty shall become void if the product is in
any way modified, improperly adjusted or abused.
MOBB Healthcare Ltd.
116A Viceroy Rd,Unit 5-6
Concord,Ontario,Canada
L4K 2M1
www.mobbhhc.com