Mobil in Time MCU-010 Operator's manual

MCU Quick Instructions Version 1.1 / 09.2018 / EN 1
MCU – Mobile Control Unit
MCU-010
Quick instructions for the operator
Read the quick instructions before beginning any work!

MCU Quick Instructions Version 1.1 / 09.2018 / EN 2
Contents
1Important notes............................................................................................................ 4
1.1 Notes to the quick instructions.............................................................................. 4
2General.......................................................................................................................... 5
3Physical components................................................................................................... 6
3.1 Safety information ................................................................................................. 6
3.2 Components on the front ...................................................................................... 7
3.3Components on the back ...................................................................................... 8
4Operation ...................................................................................................................... 9
4.1 Switching on the MCU .......................................................................................... 9
4.2 Insert SIM card (not included in scope of delivery) ................................................ 9
4.3 Unlocking the MCU ..............................................................................................10
4.4 Main menu ...........................................................................................................10
5Settings........................................................................................................................11
5.1 Display log............................................................................................................11
5.2 Change date and time ..........................................................................................13
5.3 Enter/change telephone number ..........................................................................13
5.4 Change SIM card PIN...........................................................................................14
5.5 Enter/change password .......................................................................................15
5.6 Display firmware version ......................................................................................15
5.7 Back.....................................................................................................................15
6Standard programs .....................................................................................................16
6.1 User program .......................................................................................................18
6.2 Reset all ...............................................................................................................18
7Set temperature periods.............................................................................................19
7.1 Maximum power outage time ...............................................................................19
7.2 Start user program ...............................................................................................19
7.3 Interrupt/end user program ..................................................................................20
8Error messages ...........................................................................................................22
8.1 MCU error codes..................................................................................................23
8.2 MCU status enquiry by SMS ................................................................................23
9Notes............................................................................................................................24

MCU Quick Instructions Version 1.1 / 09.2018 / EN 3
Note!
This brochure is part of the documentation for the Mobile Control Unit - MCU
Copyright
All rights reserved. The complete or partial reproduction or copying of these quick instructions
is not permitted without the prior written approval of Mobil in Time Deutschland GmbH.
Legal notice
Mobil in Time Deutschland GmbH
Im Aachtal 1A
D-78267 Aach
Tel +49 7774 939 805 0
Fax +49 7774 939 805 11
www.mobilintime.com
info@mobilintime.de
© 2018 Mobil in Time Deutschland GmbH
All rights reserved

MCU Quick Instructions Version 1.1 / 09.2018 / EN 4
1Important notes
1.1 Notes to the quick instructions
These quick instructions form part of the operating instructions - Mobile Electric
Heating. Read these quick instructions carefully before starting the Mobile Control Unit
(MCU).
1. Read these quick instructions.
2. Keep these quick instructions in a safe place.
3. Pay attention to all warnings.
4. Follow all instructions.
5. Under no circumstances, make changes to the device.
6. Always leave repairs to qualified personnel.
Target market:
These quick instructions are aimed at buyers, renters and operators of the Mobile
Control Unit - MCU.
Definition of terms
Mobile Control Unit - MCU
The Mobile Control Unit - MCU comprises the control system, built into the front panel
(lower portion) of the mobile electric heating.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 5
2General
Thank you for choosing the MCU-010 and for your confidence in the quality of our
products that goes with it. The MCU-010 circuit board consists of hardware and
firmware and serves the purpose of automated functional heating.
The purpose of the MCU-010 circuit board is to run through heating cycles, to be
adjusted by the end-user, over a defined length of time. This reduces time and effort
considerably as it does away with the need to set heating cycles manually on site. The
following sections describe in greater detail how to start and handle the MCU-010
board.
The following symbols are used in the present manual.
NOTE:
Highlights notes with information or instructions which may help you to better
understand the device and use
it more effectively.
WARNING:
A WARNING is used to draw your attention to sources of danger that might cause
material damage, injury or even death.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 6
3Physical components
In this section, the physical components of the MCU-010 are introduced one by one
and safety information provided.
3.1 Safety information
WARNING:
Before starting to set up and use the MCU
-
010 board for the first time, read the
important safety information, instructions for use and legal notices.
WARNING:
The MCU
-010 is not intended for use in a moist environment or in the rain.
WARNING:
Be sure to check that the electrical connections available match the required input
power of the MCU
-010. Check the polarity of the cables before connecting
them.
WARNING:
Have the electrical connections checked by an expert and pay attention to
country
-specific regulations.
WARNING:
To ensure that the protective arrangements provided by the MCU
-
010 are not
impaired, you may only use or install the system in accordance with the method
prescribed in this manual. No add
-ons or changes to the system are allowed.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 7
3.2 Components on the front
Components
Description
1) LED green
Lights up as soon as a heating program is active.
2) LED orange
Lights up as soon as the heating is running.
3) LED blue
Blinks if reception is poor.
Lights continuously if reception is sufficient.
4) LED red
Lights up in the event of a malfunction.
5) Display
Shows the current status of the MCU.
Ac
tivated by the press of a button.
6) USB port
Connection of USB stick.
7) Reset button
Pressing this button resets the MCU.
8) Arrow keys and OK button
The buttons serve to navigate through the menu.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 8
3.3 Components on the back
Components
Description
1) Metal mounting bracket
The mounting bracket is required for fitting and fixing the MCU.
2) Temperature sensor port
The temperature sensor is inserted here.
3) Programming interface
This interface is used exclusively for programming purposes.
4) SD card
The logs are stored on the SD card.
5) Antenna connection
Connection for wireless antenna.
6) SIM card slot
Slot for SIM card
7) Grounding bolt
The housing can be grounded via this bolt.
8) Fuse
Fuse for MCU
9) 6-pole socket
The power supply and the heating relay are connected here with an
option also to connect the fault alarm contact.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 9
4Operation
4.1 Switching on the MCU
The MCU is automatically started via the button that turns on the electric heater.
The start-up screen appears:
23.07.2018 12:34:56
Heating program: Off
ACT: +26°C
The start-up screen will always appear automatically after 30 seconds of inactivity.
The display will turn dark after 5 minutes of inactivity.
It is reactivated by pressing any key.
4.2 Insert SIM card (not included in scope of delivery)
The message “No SIM inserted” appears in the display if no SIM card has yet been
inserted in the MCU:
23.07.2018 11:26:01
No SIM inserted
OK
To receive status messages by SMS on a mobile phone, a valid SIM card with
existing credit must be inserted.
This is not absolutely necessary for operation of the MCU.
You can obtain a SIM card from your network provider.
There is a slot with a card holder for this purpose on the back of the MCU.
The SIM card can be released and removed by pressing the blue button with a sharp
object (pen or some such).
The mini SIM card is inserted as follows:
The display changes:

MCU Quick Instructions Version 1.1 / 09.2018 / EN 10
23.07.2018 11:34:37
SIM card has been
unlocked
The reception symbol lights up in blue.
If reception is poor, the lamp will blink.
4.3 Unlocking the MCU
The password must be entered in order to unlock the MCU. The standard password
on delivery is “1234”. The password can be modified at any time and must comprise
4 digits made up of the numbers 0 - 9.
The arrow keys and can be used to change the number.
The next number is selected via the arrow key.
23.07.2018 14:19:43
New password OK?
1234
No OK
After entering the password, press OK to confirm.
This will automatically take you to the main menu.
4.4 Main menu
23.07.2018 11:39:34
Main menu
The arrow keys and can be used to call up the various selection settings:
Settings
Start heating program with:
standard programs
Start heating program with:
user program
Settings menu
Display log
Change date/time
Change telephone number 1
Change telephone number 2
Change telephone number 3
Change SIM card PIN
Change password
Firmware version
Back

MCU Quick Instructions Version 1.1 / 09.2018 / EN 11
5Settings
To open the Settings menu, use the arrow key to go to “Settings” in the main
menu,
23.07.2018 11:41:40
Settings
OK
and confirm with “OK”:
23.07.2018 11:43:15
Settings menu
The arrow keys and can be used to call up various functions.
5.1 Display log
The heating logs are stored on an internal SD card and can be read through a storage
medium with a USB connection (not included in scope of delivery).
Use the arrow keys and to select between the “last” log, the “last 5” logs or “all”
logs.
23.07.2018 11:50:09
Display log
last
OK
23.07.2018 11:50:13
Display log
last 5
OK
23.07.2018 11:50:13
Display log
all
OK
You confirm your selection with the “OK” button.
After confirming your selection, you have 30 seconds to insert a USB stick. To do so,
remove the dust cap on the USB interface.
23.07.2018 11:50:43
Display log
Insert USB stick
Remaining time: 12s

MCU Quick Instructions Version 1.1 / 09.2018 / EN 12
Important note for your storage medium:
At least 100 MB free storage capacity
Max. 32 GB of available storage space
If no USB stick is inserted in the time specified, the following message appears in
the display:
23.07.2018 11:51:06
Error no USB stick
OK
Press “OK”. Status display appears:
23.07.2018 11:52:13
Heating program: Off
ACT: +23°C
Now insert the USB stick.
23.07.2018 11:52:21
USB stick inserted
Use the arrow keys and to select again between the “last” log, the “last 5” logs
or “all” logs.
Confirm the selection with “OK”.
The following messages appear in the display:
23.07.2018 11:53:11
USB stick found
23.07.2018 11:53:13
Transfer logfile
OK
23.07.2018 11:53:36
001_11-07-2018.csv

MCU Quick Instructions Version 1.1 / 09.2018 / EN 13
The USB stick can be removed again.
You can read the data on your computer via Excel.
After one second, you automatically return to the “Settings” menu item.
5.2 Change date and time
The arrow key takes you to the menu item “Change date/time”.
The number to be changed is displayed by blinking.
Select the desired day with the arrow keys and .
For days 01. – 09. a “0” is to be entered as the first digit.
Use the arrow key to change to the month; here too for months 01. – 09. a “0” is
to be entered as the first digit.
Proceed in the same way for “year” and “time”.
You confirm your selection with the “OK”.
Finally, the date and time entered are displayed for you again and you are asked if you
want to accept the setting.
23.07.2018 11:56:32
Date/time OK?
23.07.2018 11:56:18
No OK
23.07.2018 11:56:50
Date/time OK?
23.07.2018 11:56:36
Yes OK
You can use the arrow keys and to choose between “Yes” and “No” and confirm
with “OK”.
Use the arrow key to go back to reset the date and time.
If you have inserted a SIM card, the current date and time will be used by your
network provider. (network reception assumed.)
5.3 Enter/change telephone number
If you are using the unit with a SIM card, you can store telephone numbers here which
are to be notified of error messages, malfunctions or status requests via SMS. Up to
three telephone numbers can be stored.
Change telephone number 1:
23.07.2018 11:44:17
Change
telephone number 1
OK
You can use the arrow keys and to choose between telephone numbers 1 - 3.
Press “OK” to change the desired number.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 14
23.07.2018 11:59:22
Enter
telephone number 1
+ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Enter the number with the arrow keys and .
Proceed to the next number with the arrow key .
The number selected begins blinking.
Telephone numbers are always entered with their country prefix.
Instead of “00”, “+” is prescribed.
For Germany: “+49”, for Switzerland: “+41”, Austria: “+43”
The area code is entered with no “0” as the first digit.
Example using the telephone number: 077749398050.
This number must be entered as follows: +4977749398050
After completing your entry, you can save it and complete the process by entering
“OK”.
23.07.2018 12:01:02
Telephone number
saved!
Telephone numbers 2 and 3 are entered in the same way.
After one second, you automatically return to the “Settings” menu.
5.4 Change SIM card PIN
The arrow key takes you to the menu item “Change SIM card PIN”. Here you enter
“1234” as the standard, but you can change the PIN at any time.
The digit to be changed blinks, and using the arrow keys and you enter a
number from 0 – 9. Proceed to the next number with the arrow key .
23.07.2018 14:17:52
Save new PIN?
1234
No OK
Confirm your entry with “OK”.
23.07.2018 14:18:04
SIM PIN saved
After one second, you automatically return to the “Settings” menu.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 15
5.5 Enter/change password
The arrow key takes you to the menu item “Enter/change password”.
Here you enter the four-digit password (“1234” as standard).
The digit to be changed blinks, and using the arrow keys and you enter a number
from 0 – 9.
Proceed to the next number with the arrow key .
23.07.2018 14:19:43
New password OK?
1234
No OK
Confirm your entry with “OK”.
23.07.2018 14:19:55
Password changed!
After one second, you automatically return to the “Settings” menu.
When you return the loan unit, the password must be 1234!
5.6 Display firmware version
The arrow key takes you to the menu item “firmware version”.
You will find out from Mobil in Time Deutschland GmbH whether there is a new
firmware version available.
The latest version is always installed in loan units.
23.07.2018 11:44:43
Firmware version:
FW: 3.00 HW: D
5.7 Back
The arrow key takes you to the menu item «Back».
Pressing the “OK” button takes you back to “Settings”.
23.07.2018 11:48:48
Back
OK

MCU Quick Instructions Version 1.1 / 09.2018 / EN 16
6Standard programs
The MCU has three preinstalled standard heating programs.
Standard program 1 (in accordance with EN 1264-4)
Day
1
to
5
25°C
Day
6
to
10
50°C
Day
11
to
30
25°C
Standard program 2 (in accordance with Central Association for Parquet and Floor
Technology)
Day
1
25°C
Day
2
30°C
Day
3
35°C
Day
4
40°C
Day
5
to
11
45°C
Day
12
40°C
Day
13
35°C
Day
14
30°C
Day
15
25°C
Day
16
to
24
10°C
Day
25
30°C
Day
26
35°C
Day
27
40°C
Day
28
45°C
Day
29
35°C
Day
30
25°C
Standard program 3 (in accordance with ÖNORM)
Day
1
20°C
Day
2
25°C
Day
3
30°C
Day
4
35°C
Day
5
40°C
Day
6
to
13
45°C
Day
14
35°C
Day
15
to
30
25°C

MCU Quick Instructions Version 1.1 / 09.2018 / EN 17
You can use the arrow keys and to move between the 3 standard programs.
You start the standard program selected by pressing the “OK” button.
You are asked whether the desired program is to be started.
23.07.2018 14:24:20
Standard program 1
start
No OK
You can use the arrow keys and to choose between “Yes” and “No”.
The arrow key returns you.
Select “Yes” and confirm with “OK” in order to start.
First the log data are saved to the SD card.
23.07.2018 14:24:22
Log data saved
The standard program selected is displayed. The small lamp for heating operation
also lights.
23.07.2018 14:24:44
Heating program 1: On
Day: 1 from: 30 periods: 1
ACT: +26°C SETTING: 25°C
No changes may be made to the MCU while it is operating.
If you press any key, you will be asked whether the standard program is to be
terminated.
23.07.2018 14:28:51
Terminate
standard program?
Yes OK
You can use the arrow keys and to choose between “Yes” and “No”.
Confirm your entry with “OK”.
If you have terminated a standard program, you restart it. But not from the point
where you terminated it.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 18
6.1 User program
You can use the arrow keys and to choose between the settings.
23.07.2018 14:32:46
User program
Settings
6.2 Reset all
Before restarting the unit, we recommend selecting the setting “Reset all”.
23.07.2018 14:33:09
User program
Reset all
OK
If you select “OK” here, you will be asked for confirmation.
You can use the arrow keys and to choose between “Yes” and “No” and confirm
with “OK”.
You move automatically to the starting screen.
By doing so, all user programs stored by the user will be deleted. Days and the target
temperature are set to zero, power outage time to three hours, further heating to no.

MCU Quick Instructions Version 1.1 / 09.2018 / EN 19
7Set temperature periods
23.07.2018 14:33:13
Set
temperature periods
Days 00 OK
Select “OK” and set the days of heating and desired temperature for the desired
periods.
23.07.2018 14:40:03
Period: 01
set
Days 02 Temp: 47°C
You can set up to 30 periods with a total of 99 days.
You can select this using the arrow keys and .
The number to be changed blinks.
Confirm your entry with “OK”.
Enter the desired periods 1 - 30 in succession. As soon as the days have been entered,
the status is immediately active. Confirm your selection with “OK”.
7.1 Maximum power outage time
You can use the “Maximum power outage time” setting to select the maximum time
that a power failure can last to ensure that the system will automatically restart the
heating program.
23.07.2018 14:52:10
Maximum
power outage time
03 hours OK
You select the number of hours with the arrow keys and .
You confirm your selection with “OK”.
If the power failure exceeds the max. power outage time, the system will not
automatically restart and must be manually restarted.
Standard value: 3 hours
Max. value 6 hours
7.2 Start user program
23.07.2018 14:53:19
Start
user program
Yes OK

MCU Quick Instructions Version 1.1 / 09.2018 / EN 20
You can use the arrow keys and to choose between “Yes” and “No”.
You confirm your selection with “OK”. The user program which you entered
previously, will start.
The display shows the message “log data saved”.
23.07.2018 14:53:22
Log data saved
The display then changes to:
23.07.2018 14:53:23
User program
started
The status lamps “heating program active” and “heating in operation” light up.
After 5 seconds, the display changes to the status display:
23.07.2018 14:24:44
User program On
Day: 1 of: 10 periods: 1
ACT: +26°C SETTING: 30°C
7.3 Interrupt/end user program
23.07.2018 14:53:37
User program On
day: 1 of: 10 periods: 1
ACT: +26°C SETTING: 30°C
If you press any button when this display is showing, a message will appear asking
you if you wish to interrupt the user program.
Table of contents