Fleck 9000 User manual

IMPORTANT: Fill in pertinent information on page 2 for future reference.
MODEL 9000
Service Manual

MODEL 9000 ECONOMINDER
Job Specification Sheet
Printed in U.S.A.
* JOB NO. __________________________________________________________
* MODEL NO. _______________________________________________________
* WATER TEST______________________________________________________
* CAPACITY PER UNIT ____________MAX. ___________PER REGENERATION
* MINERAL TANK SIZE DIA.________HEIGHT_________
* BRINE TANK SIZE &
SALT SETTING PER REGENERATION _________________________________
Page 2
* 9000 CONTROL VALVE SPECIFICATIONS
1. Type of Timer
A) 82 minute available regeneration time, 1/15 RPM
B) 164 minute available regeneration time, 1/30 RPM
2. Type of Meter (see page 23)
A) 3/4″meter *Std. range 125 to 2,100 gal. setting
*Ext. range 625 to 10,625 gal. setting
B) 1″meter *Std. range 310 to 5,270 gal. setting
*Ext. range 1,550 to 26,350 gal. setting
3. Meter Gallon Setting ____________________________gal. (see pages 6 & 7)
4. Regeneration Program Settings (see page 5)
A) Backwash _________________________________min.
B) Brine & Slow Rinse _________________________min.
C) Rapid Rinse _______________________________min.
D) Brine Tank Refill ____________________________min.
5. Drain Line Flow Control__________________________gpm
6. Brine Refill Rate________________________________gpm
7. Injector Size __________________________________

Printed in U.S.A.
Page 3
MODEL 9000 ECONOMINDER
General, Residential & Commercial Installation Check List
WATER PRESSURE: A minimum of 25 pounds of water pressure is required for regeneration valve to operate effectively.
ELECTRICAL FACILITIES: A continuous 110 volt, 60 Hertz current supply is required. Make certain the current supply is
always hot and cannot be turned off with another switch.
EXISTING PLUMBING: Condition of existing plumbing should be free from lime and iron buildup. Piping that is built up
heavily with lime and/or iron should be replaced. If piping is clogged with iron, a separate iron filter unit should be installed
ahead of the water softener.
LOCATION OF SOFTENER AND DRAIN: The softener should be located close to a drain.
BY-PASS VALVES: Always provide for the installation of a by-pass valve.
CAUTION: Water pressure is not to exceed 120 p.s.i., water temperature is not to exceed 110°F, and the unit cannot be
subjected to freezing conditions.
1. Place the softener tank where you want to install the unit, making sure the tanks are level and on a firm base.
2. All plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be
minimum 1/2″. Overhead drains exceeding 4′above unit require 3/4″drain line.
3. Both tanks must be the same height and diameter and filled with equal amounts of media. The 1″distributor tube
(1.050 O.D.) should be cut flush with top of each tank.
4. Lubricate the distributor O-Ring seal and tank O-Ring seal with silicone lubricant. Place the main control valve on one
tank and the tank adapter on the second tank.
5. NOTE: The 1″copper tubing to interconnect the tanks must be soldered prior to assembly on the main control valve
and tank adapter. There should be a minimum of 1″distance between tanks on final assembly.
6. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting. Leave at least 6″
between the DLFC and solder joints when soldering. Failure to do this could cause damage to the drain module.
7. Teflon tape is the only sealant to be used on the drain fitting.
8. Make sure that the floor is clean beneath the salt storage tank and that it is level.
9. Place approximately 1″of water above the grid plate (if used) in your salt tank. Salt may be placed in the unit at this
time.
10. On units with a by-pass, place in by-pass position. Turn on the main water supply. Open a cold soft water tap nearby
and let run a few minutes or until the system is free from foreign material (usually solder) that may have resulted from
the installation.
11. Place the by-pass in service position and let water flow into the mineral tanks. When water flow stops, open a cold
water tap nearby and let run until air pressure is relieved.
12. Electrical: All electrical connections must be connected according to codes. Plug unit into electrical outlet. Do not
insert meter cable into the meter yet.
BRASS YOKES
TANK #2 TANK #1
TANK #2 ADAPTER
ADAPTER CLIPS
MAIN CONTROL
VALVE
OUTLET
INLET
Installation and Start-Up Instructions
WATER METER
BY-PASS
VALVE

Printed in U.S.A.
Page 4
MODEL 9000 ECONOMINDER
General, Residential & Commercial Installation Check List (Cont’d.)
13. Tank #1 has control valve.
Tank #2 has the adapter.
Look on the right side of
the control valve, it has
indicators which tells you
which position the control
valve is in during regener-
ation and which tank is
IN
SERVICE.
Photo on the
right indicates the valve is
in the service position and
tank #1 is supplying con-
ditioned water. Tank #2 is
on standby.
NOTE:
Make sure the meter cable is not
inserted in the
meter dome. Swing the timer out to expose the program
wheel
Figure 2
(to swing timer out) grab onto the lower
right corner of timer face
Figure 1
and pull outward.
14. Cycle timer into backwash position. Turn manual knob
(figure 1) so that the micro switch is riding on the 1st
set of pins (figure 2). In this position the tanks will
switch (lower piston) and the control valve will move
to the backwash position (upper piston).
You must
wait until the positioning of upper and lower pistons
has stopped before advancing the timer further.
If
advanced too fast
the control will not
home
into the
service position (it will not advance to any other
position). To correct this, rotate the manual knob back
to service and start again into backwash. Note: once
valve has positioned itself into the backwash cycle,
the homing circuit is locked in.
With all the air backwashed out, slowly cycle the timer
to the brine position; rapid rinse; and brine tank refill.
You must wait for the control drive motor to position
itself in each cycle and stop, before advancing on to
the next position.
Once back in the service position, cycle the control
valve again into the backwash position. The tanks will
switch again, and you will backwash the air head out
of the other tank. Cycle the control back to the service
position. Leave the timer in the open position.
DO NOT INSERT METER CABLE YET.
NOTE: 2 motors are available, 1/15 RPM will have a 82
min. reg. time available.
BRINE & RINSE
SECTION
(2 MIN. PER HOLE)
PIN STORAGE
PROGRAM
WHEEL FOR
CONTROL OF
REGENERATION
CYCLE
RAPID
RINSE
SECTION
(2 MIN.
PER PIN)
BRINE TANK
REFILL
SECTION
(2 MIN.
PER HOLE)
BACKWASH
SECTION
(2 MIN. PER PIN)

Printed in U.S.A.
Page 5
MODEL 9000 ECONOMINDER
Regeneration Cycle Program Setting Procedure
(Brine Tank Refill Separate From Rapid Rinse)
How To Set The Regeneration Cycle Program:
The regeneration cycle program on your water conditioner
has been factory preset, however, portions of the cycle or
program may be lengthened or shortened in time to suit
local conditions.
To expose cycle program wheel, grasp timer in lower right
hand corner and pull, releasing snap retainer and
swinging timer to the left. Meter cable
must
be removed
from meter dome before opening timer.
To change the regeneration cycle program, the program
wheel must be removed. Grasp program wheel and
squeeze protruding lugs towards center, lift program
wheel off timer. (Switch arms may require movement to
facilitate removal.)
Return timer to closed position engaging snap retainer in
back plate. Make certain all electrical wires locate above
snap retainer post.
How To Change The Length Of The Backwash Time:
The program wheel as shown in the drawing is in the
service position. As you look at the numbered side of the
program wheel, the group of pins starting at zero
determines the length of time your unit will backwash.
FOR EXAMPLE: If there are six pins in this section, the
time of backwash will be 12 min. (2 min. per pin). To
change the length of backwash time, add or remove pins
as required. The number of pins times two equals the
backwash time in minutes.
How To Change The Length Of Brine And Rinse Time:
The group of holes between the last pin in the backwash
section and the second group of pins determines the
length of time that your unit will brine and rinse. (2 min.
per hole.)
To change the length of brine and rinse time, move the
rapid rinse group of pins to give more or fewer holes in the
brine and rinse section. Number of holes times two
equals brine and rinse time in minutes.
How To Change The Length Of Rapid Rinse:
The second group of pins on the program wheel
determines the length of time that your water conditioner
will rapid rinse. (2 min. per pin.)
To change the length of rapid rinse time, add or remove
pins at the higher numbered end of this section as
required. The number of pins times two equals the rapid
rinse time in minutes.
NOTE: Program wheels having 0 to 82 min. cycle times,
use “1” min. per pin or hole to set regeneration times. The
layout of pins and holes on the program wheel follow the
same procedure as on this page.
How To Change The Length Of Brine Tank Refill Time:
The second group of holes on the program wheel
determines the length of time that your water conditioner
will refill the brine tank (2 min. per hole.)
To change the length of refill time, move the two pins at
the end of the second group of holes as required.
The regeneration cycle is complete when the outer micro-
switch is tripped by the two pin set at end of the brine tank
refill section. The program wheel, however, will continue
to rotate until the inner micro-switch drops into the notch
on the program wheel. See page 6 for salt setting
calculations, and page 24 for general timer settings.
BRINE & RINSE
SECTION
(2 MIN. PER HOLE)
PIN STORAGE
PROGRAM
WHEEL FOR
CONTROL OF
REGENERATION
CYCLE
RAPID
RINSE
SECTION
(2 MIN.
PER PIN)
BRINE TANK
REFILL
SECTION
(2 MIN.
PER HOLE)
BACKWASH
SECTION
(2 MIN. PER PIN)

Printed in U.S.A.
Page 6
MODEL 9000 ECONOMINDER
Time Brine Refill & Meter Setting Procedure
PROGRAMMING
1. Your control valve has been factory set for backwash; brine and slow rinse; rapid rinse and brine tank fill times. See
the control valve specification sheet (pg. 24). Any of these times can be changed by repositioning the pins and
holes or adding more pins (see pg. 5). Note that two different speed timer motors are used, one allows for an 82
minute maximum regeneration time (each pin or hole = 1 min.). The other allows for 164 minute maximum
regeneration time (each pin or hole = 2 min.).
2. The 9000 Control has a separate brine tank fill cycle. Your desired salt setting must be calculated, using the blue
(.25 gpm) or black (.5 gpm) or red (1.0 gpm) rate of refill (in gpm) times your timer setting. Then using one gallon of
fresh water dissolving approximately 3 lbs. salt, calculate your refill time.
ie: A desired 9 lb. salt setting: The unit has a .5 gpm refill rate, we will need a 3 gallon fill. (3 gal. x 3 lb./gal. = 9 lb.
salt). The timer refill section would have to be set at 6 minutes. (6 min x .5 gpm = 3 gal. fill)
Note: There always must be 2 pins at the end of your refill time. This is to stop the fill cycle. With your
regeneration times now set, place timer back to its original position, making sure the lower right hand
corner snaps back into the backplate and the meter cable slides through the backplate and does not bind.
3. Stting the gallon wheel
Knowing the amount of resin you have in each tank and your salt setting per regeneration, calculate the gallons
available, using the following capacities as a guide:
One Cubic Foot of Resin
Salt Setting at Capacity per Regeneration
15 lb 30,000 grains
10 lb 27,000 grains
8 lb 24,000 grains
6 lb 20,000 grains
Gallons available = Capacity per Regeneration.
Compensated Hardness of H2O
ie: 24 grain water; each tank having 1 cubic foot of resin and salted at 8 lb. of salt, yielding a usable 24,000 grain
capacity: 1,000 gallons available = 24,000 gr. capacity
24 gr. water
DO NOT SET THIS FIGURE - GO TO STEP 4
3. Since the 9000 Valve regenerates with soft water from the other tank, you must subtract the water used for
regeneration. Take each of your regeneration cycles and calculate the water used. (Use the injector Slow Rinse
rate chart supplied, see pg. 24.)
ie: Unit is set up for a 10 tank having 2.4 gpm backwash, #1 injector, .5 gpm refill, timer set up for
8 min.
backwash, 54 min. brine and rinse, 6 min. rapid rinse, 6 min. brine tank fill.
A. Backwash - 8 mins. x 2.4 gpm = 19.2 gallons
B. Brine and Rinse - 54 mins. x .33 gpm = 17.8gallons
(See injector chart slow rinse flow, pg. 23)
C. Rapid Rinse - 6 mins. x 2.4 gpm = 14.4 gallons
D. Brine Tank Fill - 6 mins. x .5 gpm = 3.0 gallons
Total Regeneration Water = 54.4gallons

Printed in U.S.A.
Page 7
MODEL 9000 ECONOMINDER
Time Brine Refill & Meter Setting Procedure (Cont’d.)
If we have 1000 gallons available from Step 3, we want to subtract the regeneration water used from the total water
available.
1000 gallons available - 55. gallons used = 945 gallons setting (in regeneration)
4. NOW set Meter wheel at approximately 950 gallons. Lift the inner dial of the meter program wheel so that you can
rotate it freely. Position the white dot opposite the 950 gallon setting (see diag. below).
NOTE: There is a slight delay time from the time the meter zero’s out and when the cycle starts. Units using the 1/
15 rpm motor, 82 minute regeneration time available (tanks 6″thru 12″)havea
9 minute delay
. Units using
the 1/30 rpm motor, 180 minute regeneration time available (tanks 13″and larger) have an
18 minute
delay
. Typically on residential equipment this delay period is not critical. On commercial applications, this
must be taken into consideration and continuous flows for 9 minutes or 18 minutes should be subtracted
from water available.
NOW 1. Insert Meter cable into Meter.
2. Check Bypass.
3. Plug unit in.

Printed in U.S.A.
Page 8
MODEL 9000 ECONOMINDER
1 - SERVICE POSITION
Hard water enters the unit at the valve inlet, flows around
the lower piston, and down through the mineral in the first
tank. Conditioned water enters the center tube through
the bottom distributor, flows up through the center tube,
around the lower piston, through the meter, and out the
valve outlet. The second mineral tank is regenerated and
on standby.
2 - TANKS SWITCHING
(the meter has initiated a regeneration)
Hard water enters the unit at the valve inlet, flows around
the lower piston, through the pipe leading to the second
mineral tank, and down through the mineral in the second
tank. Conditioned water enters the center tube of the
second tank through the bottom distributor, flows up
through the center tube, through the pipe leading back to
the main valve, around the lower piston, through the
meter, and out the valve outlet. The depleted first mineral
tank is out of the flow path, and ready for regeneration.
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK

Printed in U.S.A.
Page 9
MODEL 9000 ECONOMINDER
3 - BACKWASH
Conditioned water from the second mineral tank flows
around the lower piston, around the upper piston,
through the center of the lower piston, down the center
tube, up through the mineral, around the upper piston,
and out the drain line.
4 - BRINE DRAW
Conditioned water from the second mineral tank flows
around the lower piston, around the upper piston, into
the injector housing, and down through the nozzle and
throat to draw brine from the brine tank. Brine flows
around the upper piston, down through the mineral, into
the center tube through the bottom distributor, up the
center tube, through the center of the lower piston,
through the center of the upper piston, and out through
the drain line.
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK

Printed in U.S.A.
Page 10
MODEL 9000 ECONOMINDER
5 - SLOW RINSE
Conditioned water from the second mineral tank flows
around the lower piston, around the upper piston, into the
injector housing, down through the nozzle and throat,
around the upper piston, down through the mineral, into
the center tube through the bottom distributor, up the
center tube, through the center of the lower piston,
through the center of the upper piston, and out through
the drain line.
6 - RAPID RINSE
Conditioned water from the second mineral tank flows
around the lower piston, around the upper piston, and
down through the mineral in the first tank. Rinse water
from the mineral bed enters the center tube through the
bottom distributor, flows up the center tube, through the
center of the lower piston, through the center of the upper
piston, and out through the drain line.
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK

Printed in U.S.A.
Page 11
MODEL 9000 ECONOMINDER
7 - BRINE TANK FILL POSITION
Conditioned water from the second mineral tank flows
around the lower piston, around the upper piston, into the
injector housing, through the brine line flow control,
through the brine valve, and into to brine tank. No water
flows through the first mineral tank.
8 - SERVICE (TANKS SWITCHED)
Hard water enters the unit at the valve inlet, flows around
the lower piston, through the pipe leading to the second
mineral tank, and down through the mineral in the second
tank. Conditioned water enters the center tube of the
second tank through the bottom distributor, flows up
through the center tube, through the pipe leading back to
the main valve, around the lower piston, through the
meter, and out the valve outlet. The regenerated first
mineral tank is out of the flow path, and ready for use
when the second mineral tank becomes depleted.
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK
BRINE VALVE
FLOW CONTROL
DRAIN
MINERAL TANK #1 BRINE TANK

Printed in U.S.A.
Page 12
MODEL 9000 ECONOMINDER
Drive Assembly
(See opposite page for parts list)
1
3
4
5
6
7
89
10
11
12
14
15
16 17 18 19 20
21
22
23
24
25
26
27
28 29
30
32
33
34
35
36
39
1
2
3
2
34
42

Printed in U.S.A.
Page 13
MODEL 9000 ECONOMINDER
Drive Assembly
Parts List
Item No. Quantity Part No. Description
1. . . . . . . . . . . 2 . . . . . . . . . . . 11335 . . . . . . . . . . . . . . . Screw, #4-40
2. . . . . . . . . . . 2 . . . . . . . . . . . 18564 . . . . . . . . . . . . . . . Screw, Hex Washer #6-20
3. . . . . . . . . . . 2 . . . . . . . . . . . 13363 . . . . . . . . . . . . . . . Washer
4. . . . . . . . . . . 1 . . . . . . . . . . . 14921 . . . . . . . . . . . . . . . Piston Rod Link, Upper
5. . . . . . . . . . . 1 . . . . . . . . . . . 15019 . . . . . . . . . . . . . . . Piston Rod Link, Lower
6. . . . . . . . . . . 2 . . . . . . . . . . . 18728 . . . . . . . . . . . . . . . Nut, Clip, #8-32
7. . . . . . . . . . . 1 . . . . . . . . . . . 15203 . . . . . . . . . . . . . . . Wiring Harness - Timer
8. . . . . . . . . . . 1 . . . . . . . . . . . 11838 . . . . . . . . . . . . . . . Power Cord
9. . . . . . . . . . . 1 . . . . . . . . . . . 15202 . . . . . . . . . . . . . . . Wiring Harness - Drive
10 . . . . . . . . . . 1 . . . . . . . . . . . 15134 . . . . . . . . . . . . . . . Drive Gear, Assembly, Lower
11 . . . . . . . . . . 1 . . . . . . . . . . . 15135 . . . . . . . . . . . . . . . Drive Gear
12 . . . . . . . . . . 1 . . . . . . . . . . . 14896 . . . . . . . . . . . . . . . Geneva Wheel
14 . . . . . . . . . . 4 . . . . . . . . . . . 12681 . . . . . . . . . . . . . . . Wire Connector
15 . . . . . . . . . . 2 . . . . . . . . . . . 19367 . . . . . . . . . . . . . . . Cover Screw Assembly
16 . . . . . . . . . . 1 . . . . . . . . . . . 15175 . . . . . . . . . . . . . . . Position Decal
17 . . . . . . . . . . 2 . . . . . . . . . . . 14917 . . . . . . . . . . . . . . . Retaining Ring
18 . . . . . . . . . . 1 . . . . . . . . . . . 15199 . . . . . . . . . . . . . . . Ground Plate
19 . . . . . . . . . . 1 . . . . . . . . . . . 14430 . . . . . . . . . . . . . . . Screw, Hex Washer #6
20 . . . . . . . . . . 2 . . . . . . . . . . . 13602 . . . . . . . . . . . . . . . Screw, Round Hd #6-32
21 . . . . . . . . . . 1 . . . . . . . . . . . 18739 . . . . . . . . . . . . . . . Drive Motor - 220V., 50 Hz
1 . . . . . . . . . . . 18738 . . . . . . . . . . . . . . . Drive Motor - 120V., 60 Hz
1 . . . . . . . . . . . 18737 . . . . . . . . . . . . . . . Drive Motor 24V., 50-60 Hz
22 . . . . . . . . . . 1 . . . . . . . . . . . 15131 . . . . . . . . . . . . . . . Control Panel
23 . . . . . . . . . . 2 . . . . . . . . . . . 15172 . . . . . . . . . . . . . . . Screw, Flat Hd #4-40
24 . . . . . . . . . . 2 . . . . . . . . . . . 10340 . . . . . . . . . . . . . . . Washer, Lock #4
25 . . . . . . . . . . 1 . . . . . . . . . . . 10218 . . . . . . . . . . . . . . . Micro Switch
26 . . . . . . . . . . 2 . . . . . . . . . . . 10339 . . . . . . . . . . . . . . . Nut, Hex #4-40
27 . . . . . . . . . . 7 . . . . . . . . . . . 15331 . . . . . . . . . . . . . . . Screw, Hex Washer #10-24
28 . . . . . . . . . . 1 . . . . . . . . . . . 15133 . . . . . . . . . . . . . . . Drive Gear, Assembly, Upper
29 . . . . . . . . . . 1 . . . . . . . . . . . 15132 . . . . . . . . . . . . . . . Triple Cam
30 . . . . . . . . . . 1 . . . . . . . . . . . 13547 . . . . . . . . . . . . . . . Strain Relief
31 . . . . . . . . . . 1 . . . . . . . . . . . 15810 . . . . . . . . . . . . . . . Retaining Ring, Drive Gear (not shown)
32 . . . . . . . . . . 1 . . . . . . . . . . . 15323 . . . . . . . . . . . . . . . Guide Pin Upper Piston Rod Link
33 . . . . . . . . . . 1 . . . . . . . . . . . 15368 . . . . . . . . . . . . . . . Cable Guide
34 . . . . . . . . . . 2 . . . . . . . . . . . 15372 . . . . . . . . . . . . . . . Washer, Thrust
35 . . . . . . . . . . 1 . . . . . . . . . . . 15216 . . . . . . . . . . . . . . . Meter Cable Assy. - 1″Meter
1 . . . . . . . . . . . 15425 . . . . . . . . . . . . . . . Meter Cable Assy. - 3/4″Meter
36 . . . . . . . . . . 2 . . . . . . . . . . . 15692 . . . . . . . . . . . . . . . Spacer
37 . . . . . . . . . . 1 . . . . . . . . . . . 10302 . . . . . . . . . . . . . . . Insulator (not shown)
38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
39 . . . . . . . . . . 1 . . . . . . . . . . . 16433 . . . . . . . . . . . . . . . Micro Switch, Program
40 . . . . . . . . . . 1 . . . . . . . . . . . 18699-XX . . . . . . . . . . . . Cover, Top (Now Shown)
41 . . . . . . . . . . 1 . . . . . . . . . . . 14779-XX . . . . . . . . . . . . Cover, Bottom (Not Shown)
1 . . . . . . . . . . . 19291-020. . . . . . . . . . . . Cover, 1 Piece, Black
42 . . . . . . . . . . 2 . . . . . . . . . . . 15173 . . . . . . . . . . . . . . . Screw

Printed in U.S.A.
Page 14
MODEL 9000 ECONOMINDER
Control Valve Assembly
(See opposite page for parts list)
1
2
3
4
5
6
7
89
10
11
12
14 15
16
17 18 19
20 21 22 23 24
25
26
27
28
29
30
31
32
34
35
36
37
38
39
40
13
41 42
43 44
45
47
48
29
16
16
3
5
7
6

Printed in U.S.A.
Page 15
MODEL 9000 ECONOMINDER
Control Valve Assembly
Parts List
Item No. Quantity Part No. Description
1 . . . . . . . . . 1 . . . . . . . . . . .14861-01 . . . . . . . . . . . . Valve Body
2 . . . . . . . . . 1 . . . . . . . . . . .14914. . . . . . . . . . . . . . . Piston, Upper
3 . . . . . . . . . 2 . . . . . . . . . . .14309. . . . . . . . . . . . . . . Piston Rod Retainer
2 . . . . . . . . . . .16590. . . . . . . . . . . . . . . Piston Rod Retainer, HW
4 . . . . . . . . . 1 . . . . . . . . . . .14919. . . . . . . . . . . . . . . Piston Rod, Upper
5 . . . . . . . . . 2 . . . . . . . . . . .13446. . . . . . . . . . . . . . . End Plug Assy.
2 . . . . . . . . . . .13446-01 . . . . . . . . . . . . End Plug Assy., HW
6 . . . . . . . . . 12 . . . . . . . . . .14241. . . . . . . . . . . . . . . Spacer
12 . . . . . . . . . .14241-01 . . . . . . . . . . . . Spacer, HW
7 . . . . . . . . . 16 . . . . . . . . . .13242. . . . . . . . . . . . . . . Seal
16 . . . . . . . . . .18759. . . . . . . . . . . . . . . Seal, HW
8 . . . . . . . . . 1 . . . . . . . . . . .14920. . . . . . . . . . . . . . . Piston Rod, Lower
9 . . . . . . . . . 1 . . . . . . . . . . .14905. . . . . . . . . . . . . . . Piston, Lower
10 . . . . . . . . . 1 . . . . . . . . . . .11710. . . . . . . . . . . . . . . O-Ring, -215
11 . . . . . . . . . 1 . . . . . . . . . . .12281. . . . . . . . . . . . . . . O-Ring, -338
12 . . . . . . . . . 1 . . . . . . . . . . .11981-01 . . . . . . . . . . . . Retaining Ring
13 . . . . . . . . . 1 . . . . . . . . . . .16098. . . . . . . . . . . . . . . Washer, Brine Valve (Nylon)
14 . . . . . . . . . 1 . . . . . . . . . . .11973. . . . . . . . . . . . . . . Spring, Brine Valve
15 . . . . . . . . . 1 . . . . . . . . . . .13165. . . . . . . . . . . . . . . Brine Valve Cap
16 . . . . . . . . . 3 . . . . . . . . . . .13302. . . . . . . . . . . . . . . O-Ring, -014
17 . . . . . . . . . 1 . . . . . . . . . . .12550. . . . . . . . . . . . . . . Quad Ring, -009
18 . . . . . . . . . 1 . . . . . . . . . . .13167. . . . . . . . . . . . . . . Brine Valve Spacer
19 . . . . . . . . . 1 . . . . . . . . . . .14925. . . . . . . . . . . . . . . Brine Valve Stem
20 . . . . . . . . . 1 . . . . . . . . . . .12626. . . . . . . . . . . . . . . Brine Valve Seat
21 . . . . . . . . . 1 . . . . . . . . . . .15215. . . . . . . . . . . . . . . Injector Body
22 . . . . . . . . . 1 . . . . . . . . . . .10914. . . . . . . . . . . . . . . Injector Throat - Specify Size pg. 24
10226. . . . . . . . . . . . . . . Injector Throat, SS
23 . . . . . . . . . 1 . . . . . . . . . . .10913. . . . . . . . . . . . . . . Injector Nozzle, Specify Size pg. 24
10225. . . . . . . . . . . . . . . Injector Nozzle, SS
24 . . . . . . . . . 1 . . . . . . . . . . .13303. . . . . . . . . . . . . . . O-Ring, -021
25 . . . . . . . . . 1 . . . . . . . . . . .13166. . . . . . . . . . . . . . . Injector Cover
26 . . . . . . . . . 1 . . . . . . . . . . .16595. . . . . . . . . . . . . . . Spacer
27 . . . . . . . . . 1 . . . . . . . . . . .13387. . . . . . . . . . . . . . . Screw, Hex Hd #10-24
28 . . . . . . . . . 1 . . . . . . . . . . .13361. . . . . . . . . . . . . . . Spacer, Injector
29 . . . . . . . . . 2 . . . . . . . . . . .13301. . . . . . . . . . . . . . . O-Ring, -011
30 . . . . . . . . . 1 . . . . . . . . . . .13497. . . . . . . . . . . . . . . Air Disperser
31 . . . . . . . . . 1 . . . . . . . . . . .15348. . . . . . . . . . . . . . . O-Ring, -563
32 . . . . . . . . . 1 . . . . . . . . . . .10227. . . . . . . . . . . . . . . Injector Screen
33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Assigned
34 . . . . . . . . . 1 . . . . . . . . . . .13244. . . . . . . . . . . . . . . B.L.F.C. Fitting
37 . . . . . . . . . 1 . . . . . . . . . . .16173. . . . . . . . . . . . . . . B.L.F.C. Fitting - Bored*
35 . . . . . . . . . 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.L.FC. Button - Specify Size pg. 24
36 . . . . . . . . . 1 . . . . . . . . . . .13245. . . . . . . . . . . . . . . B.L.F.C. Button Retainer
1 . . . . . . . . . . .12977. . . . . . . . . . . . . . . O-Ring, -015
38 . . . . . . . . . 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D.L.F.C. Button - Specify Size pg. 24
39 . . . . . . . . . 1 . . . . . . . . . . .13173. . . . . . . . . . . . . . . D.L.F.C. Button Retainer
40 . . . . . . . . . 1 . . . . . . . . . . .10332. . . . . . . . . . . . . . . Tube Insert - 3/8″
1 . . . . . . . . . . .15415. . . . . . . . . . . . . . . Tube Insert - 1/2″*
41 . . . . . . . . . 1 . . . . . . . . . . .10330. . . . . . . . . . . . . . . Ferrule - 3/8″
1 . . . . . . . . . . .16124. . . . . . . . . . . . . . . Ferrule - 1/2″*
42 . . . . . . . . . 1 . . . . . . . . . . .10329. . . . . . . . . . . . . . . Tube Nut - 3/8″
1 . . . . . . . . . . .16123. . . . . . . . . . . . . . . Tube Nut - 1/2″*
43 . . . . . . . . . 1 . . . . . . . . . . .14928. . . . . . . . . . . . . . . Stub End Plug
44 . . . . . . . . . 1 . . . . . . . . . . .14906. . . . . . . . . . . . . . . End Plate
45 . . . . . . . . . 4 . . . . . . . . . . .15137. . . . . . . . . . . . . . . Screw, Hex Washer, #10-24
46 . . . . . . . . . 1 . . . . . . . . . . .16140. . . . . . . . . . . . . . . Adapter, 1/2″T to 1/4″P (not shown)*
47 . . . . . . . . . 1 . . . . . . . . . . .15471. . . . . . . . . . . . . . . Brine Valve Stand Off
48 . . . . . . . . . 1 . . . . . . . . . . .13315. . . . . . . . . . . . . . . Screw, Hex Washer, #10-24
Note: For Hot Water Delete Items
41 & 42 and use
18698. .Nut & Sleeve Assy. 3/8″
15414. .Nut & Sleeve Assy. 1/2″
* These parts are used with #4
Injector and 2 GPM or larger
Brine Line Flow Control
(B.L.F.C.). Items 34, 35 and 36
are not used.

Printed in U.S.A.
Page 16
MODEL 9000 ECONOMINDER
Second Tank Adapter Assembly
PARTS LIST
Item No. Quantity Part No. Description
1 . . . . . . . . . . . 1. . . . . . . . . . . .14864-01 . . . . . . . . . . . . . 2nd Tank Adapter
2 . . . . . . . . . . . 8. . . . . . . . . . . .13305. . . . . . . . . . . . . . . . O-Ring, -119
3 . . . . . . . . . . . 1. . . . . . . . . . . .11710. . . . . . . . . . . . . . . . O-Ring, -215
4 . . . . . . . . . . . 1. . . . . . . . . . . .12281. . . . . . . . . . . . . . . . O-Ring, -338
5 . . . . . . . . . . . 2. . . . . . . . . . . .13708-40 . . . . . . . . . . . . . Yoke
1. . . . . . . . . . . . 15823-XX. . . . . . . . . . . . .Yoke Assy. Specify Tank Size
6 . . . . . . . . . . . 4. . . . . . . . . . . .13255. . . . . . . . . . . . . . . . Hold-Down Clip
7 . . . . . . . . . . . 4. . . . . . . . . . . .14202. . . . . . . . . . . . . . . . Screw, Hex Hd #8-32
8 . . . . . . . . . . . 4. . . . . . . . . . . .15078. . . . . . . . . . . . . . . . Coupling
9 . . . . . . . . . . . 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pipe - 1″Copper Cut to Length
1
2
3
4
5
6
78
6
7
2
282
6
7
6
7
28
2
28
2
5

Printed in U.S.A.
Page 17
MODEL 9000 ECONOMINDER
Air Check
PARTS LIST
Item No. Quantity Part No. Description
1. . . . . . . . . . . 1 . . . . . . . . . . . 10332 . . . . . . . . . . . . . . . Tube Insert 3/8″
2. . . . . . . . . . . 1 . . . . . . . . . . . 10330 . . . . . . . . . . . . . . . Ferrule 3/8″
3. . . . . . . . . . . 1 . . . . . . . . . . . 10329 . . . . . . . . . . . . . . . Tube Nut 3/8″
4. . . . . . . . . . . 1 . . . . . . . . . . . Not Supplied . . . . . . . . . . Brine Line Tube (3/8 Flexible Tube)
5. . . . . . . . . . . 1 . . . . . . . . . . . 12794 . . . . . . . . . . . . . . . 90°Elbow - 3/8″T to 3/8″T
1 . . . . . . . . . . . 13555 . . . . . . . . . . . . . . . 90°Elbow - 3/8″T to 3/8″T, HW
6. . . . . . . . . . . 1 . . . . . . . . . . . 60002 . . . . . . . . . . . . . . . #500 Air Check Assembly
1 . . . . . . . . . . . 60003 . . . . . . . . . . . . . . . #500 Air Check Assembly, HW
For Use With 2 GPM Flow Control
10 . . . . . . . . . . . . . . . . . . . . . . . 15415 . . . . . . . . . . . . . . . Tube Insert 1/2″
11 . . . . . . . . . . . . . . . . . . . . . . . 16123 . . . . . . . . . . . . . . . Ferrule 1/2″
12 . . . . . . . . . . . . . . . . . . . . . . . 16124 . . . . . . . . . . . . . . . Tube Nut 1/2″
13 . . . . . . . . . . . . . . . . . . . . . . . 15413 . . . . . . . . . . . . . . . Elbow
14 . . . . . . . . . . . . . . . . . . . . . . . 60009 . . . . . . . . . . . . . . . #900 Air Check Assembly
60009-01. . . . . . . . . . . . . #900 Air Check Assembly, HW
1
2
3
4
5
6
10
11
12
13

Printed in U.S.A.
Page 18
MODEL 9000 ECONOMINDER
1″Meter Assembly
PARTS LIST
Item No. Quantity Part No. Description
1 . . . . . . . . . . . 4 . . . . . . . . . . .12112. . . . . . . . . . . . . . . . Screw, Hex Hd #10-24
2 . . . . . . . . . . . 1 . . . . . . . . . . .15218. . . . . . . . . . . . . . . . Meter Cover Assy.
15237. . . . . . . . . . . . . . . . Meter Cover Assy. (Ext. range)
3 . . . . . . . . . . . 1 . . . . . . . . . . .13847. . . . . . . . . . . . . . . . O-Ring, -137
4 . . . . . . . . . . . 1 . . . . . . . . . . .13509. . . . . . . . . . . . . . . . Impeller
1 . . . . . . . . . . . 13509-01 . . . . . . . . . . . . . Impeller, HW
5 . . . . . . . . . . . 1 . . . . . . . . . . .13882. . . . . . . . . . . . . . . . Impeller Post
6 . . . . . . . . . . . 1 . . . . . . . . . . .15043. . . . . . . . . . . . . . . . Meter Body 1″- 11-1/2 N.P.T.
1 . . . . . . . . . . . 15043-10 . . . . . . . . . . . . . Meter Body 1″- 11 B.S.P.
7 . . . . . . . . . . . 1 . . . . . . . . . . .14960. . . . . . . . . . . . . . . . Flow Straightener
8 . . . . . . . . . . . 4 . . . . . . . . . . .13305. . . . . . . . . . . . . . . . O-Ring, -119
9 . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Not Assigned
10. . . . . . . . . . . .2 . . . . . . . . . . .15078. . . . . . . . . . . . . . . . Coupling
11. . . . . . . . . . . 2 . . . . . . . . . . .13255. . . . . . . . . . . . . . . . Adapter Clip
12. . . . . . . . . . . 2 . . . . . . . . . . .14202. . . . . . . . . . . . . . . . Screw, Hex Hd #8-32
1
2
3
4
5
6
78
10
11
12
8
8
10
8
11 12

Printed in U.S.A.
Page 19
MODEL 9000 ECONOMINDER
3/4″Meter Assembly
PARTS LIST
Item No. Quantity Part No. Description
1. . . . . . . . . . . 4 . . . . . . . . . . . 12473 . . . . . . . . . . . . . . . Screw, Hex Washer #10-24
2. . . . . . . . . . . 1 . . . . . . . . . . . 14038 . . . . . . . . . . . . . . . Meter Cover Assembly - Standard
. . . . . . . . . . . . . . . . . . . . . . . . 15150 . . . . . . . . . . . . . . . Meter Cover Assembly - Extended Range
3. . . . . . . . . . . 1 . . . . . . . . . . . 13847 . . . . . . . . . . . . . . . O-Ring, -137
4. . . . . . . . . . . 1 . . . . . . . . . . . 13509 . . . . . . . . . . . . . . . Impeller
5. . . . . . . . . . . 4 . . . . . . . . . . . 13314 . . . . . . . . . . . . . . . Screw, Hex Washer #8-18
6. . . . . . . . . . . 4 . . . . . . . . . . . 13255 . . . . . . . . . . . . . . . Adapter Clip
7. . . . . . . . . . . 1 . . . . . . . . . . . 13821 . . . . . . . . . . . . . . . Meter Body
8. . . . . . . . . . . 4 . . . . . . . . . . . 13305 . . . . . . . . . . . . . . . O-Ring, -119
9. . . . . . . . . . . 1 . . . . . . . . . . . 14613 . . . . . . . . . . . . . . . Flow Straightener
1
2
3
4
5
6
7
8
9

Printed in U.S.A.
Page 20
MODEL 9000 ECONOMINDER
Timer Assembly
(See opposite page for parts list)
1
2
3
4
56
7
8910
11
12
14
15 1617
18
19
20
22 23 24 25
26
27
28
29
30
31
32
33 35
36
37
38
39
40
13
41
26
26
20 17
Other manuals for 9000
1
Table of contents
Other Fleck Control Unit manuals