After the ZigBee gateway is configured,
enter the gateway to add sub-devices,
and wait for the actuator to be powered
on and the system self-check is completed.
long press access to setting ,short
press to choose icon,short press
to enter network connected mode, then long
press , flashing access network
connected mode.
Please refer to the gateway manual for
Zigbee gateway configuration.
Holiday mode:press 3s access to setting interface, short press to choose holiday
mode then short press enter temperature setting, short press setting days
setting,press to adjust value,under holiday mode, short press to exit holiday mode.
Open Windows Function: 1. The actuator turns off the window opening function by
default, if you need to use it, you can turn it on in the advanced option A2 setting [reset
when changing the battery]
2. When the actuator detects that the indoor temperature drops quickly to the valve
closed setting value (adjustment range: 5℃-25℃), the valve will be closed for 15
minutes (adjustment range: 5-60 minutes), and it will be closed after the window
opening function is completed. Return to the original operating mode, but the valve will
be fully opened.
Children lock; Open Window function
Time setting interface: hours setting; minutes setting
Zigbee WIFI Radiator Actuator User Manual
Many thanks for your selection of our products and services, and also for your
trust and support to us.
Search for “Smart Life”
Download the Wifi App with the
following icon
Add your gateway to the App,then add your radiator
actuator to your gateway in the App.
Product Specifications
Power: 2* AA alkaline batteries
Display accuracy::0.5℃
Probe sensor::NTC(10k)1%
Maximum route:4.5mm
Default range of temperature adjustment:5~35°C
Working environment temperature::-10~60°C
Insulating condition: 0-50℃
Running program: Set per 1 week as a cycle
Size(mm):53*89.5mm
Range of temperature display::1~70°C
Maximum current:90mA
Thread size:M30*1.5
Displays & Bu�ons
No:
No: keys Represent
Icon
A
B
C
D
E
F
1.Short press to switch manual mode and auto mode
2.Long press to access setting interface
3.Confirm key
1.Decrease key
2.Long press 3s to lock/unlock keys
1.Increase Key;
2.Long press 3s access Boost function setting, Press any key during operation
to exit this function and return to the original working mode
Installation and initial commissioning
Malfunction
Error Code Description
E1 Motor fault
E2 Sensor fault
Flashing show low battery
Special Function description
Time setting
Note:Cellphone and gateway must connect
under the same WIFI router.
Auto Mode; Low battery;
After power on, the screen will show all for 3
seconds.
flashing,press display hour setting,press or to adjust value,press again display
minutes setting,press or to adjust value,press again to set week,press or to adjust
value,press to confirm setting and remember time.
Note:after actuator self-testing,under normal working status,if need to modify time, please and
3s access to setting. And press to choose , short press enter time setting. the same as
above method.
Display “AD”, press Start system self-check, when display “1”, this is the first step of system
self-check. When Display “2”, this is the second step, after finish self-check, If there is no fault
prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first,
otherwise it will not enter the normal working state.
Enjoy Our Smart Life
Holiday mode; Boost mode; WIFI connection status
Auto mode period; Set temperature/advanced options
Valve status