Monarch Duplex Series Battery Operated Water Softener
PROGRAMMING & INSTALLATION INSTRUCTIONS
Thank you for choosing our water softener. Please read the following carefully, which
if followed correctly, should ensure the installation is trouble free.
•
Always observe the water byelaws.
•
Ensure there is only one rising main.
•
Make sure you have allowed space for access to the unit for salt filling and for any
possible maintenance in the future.
•
Check the water pressure and locate the rising main, and a drain facility. Be aware of
condensation on pipes and the outside of the softener occurring in warm
environments.
•
This softener has reversible valve technology, meaning the valve connector can be
located on either side of the softener allowing easier installation and siting. If you would
like to relocate the valve, connect please see
S
tep
S
in these instructions.
B.SITING THE SOFTENER - Fig 1
•
Where possible, this should be close to the rising main.
•
Tee off for mains water supply to outside tap if applicable.
•
Rapid-Fit bypass has a 3/8" speedfit connection for flexi tube connection to a dedicated
drinking water faucet. Monarch
'
s Bari faucet and Smtr length of 3/8" tubing code is
MW38CFK.
•
The distance between the softener and the dr ain should be as short as possible, to
ensur e that both the drain and the overflow are not subject to freezing, or over 120
°
F/49
°
C.
•
If siti ng the softener within a kitchen cupboard, loft etc. ensure that the base/ floor is
adequately supported.
•
If the softener is being installed in your loft, 1st, 2nd floor etc, it is strongly
recommended to house the softener within a 25-gallon plastic tank and insulate well.
Monarch take no responsibility of any water damage etc if this recommendation is not
applied.
•
The overflow on the plastic tank should be below the overflow of the softener and a
minimum of ¾"in size. Failure to install the softener in a suitable tank will void the
Guarantee.
C.
CHECK VALVE
Domestic Ion exchange water softeners are in fluid category 2. The Rapid-Fit bypass
incorporates a high flow check valve in accordance with this requirement.
All other
applications require a double check valve.
D.
DRINKING WATER FACILITY - See Installation Requirements Diagram
In compliance with U.K. Water Regulations a tap for drinking water purposes should be
left on the hard water supply. See Rapid-Fit bypass 3/8" speedfit connection.
E.
MATERIAL CHECK LIST
•
P
S
U02
7
HE
&
P
SP
022HE includes a Monarch Rapid-Fit bypass installation kit
suitable for all 15mm and 22mm plumbing systems.
•
For 15mm pipework use the compression reducers supplied.
PLANNING THE INSTALLATION
2
A.