Installation information is for reference only. See the
Installation Instructions shipped with the product for
complete details and before attempting to install the
range.
Caution: These ranges weigh up to 700 pounds.
Some disassembly will reduce the weight
considerably. Due to the weight and size of the
range, to reduce the risk of personal injury or
damage to the product, take note of the following:
• TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION OF 36" AND 30" RANGES.
• THREE PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION OF 48" RANGES.
Gas Supply Range
The natural gas models are designed to operate at
5" water column pressure. For proper operation, the
pressure of the natural gas supplied to the regulator
must be between 7" and 13" water column.
The LP models are designed to operate at 10" water
column pressure. For proper operation, the pressure
of the LP gas supplied to the regulator must be
between 11" and 13" water column.
All models can be ordered to operate on NATURAL
or LP gas. Models ordered to operate on NATURAL
gas are shipped with an LP conversion kit. Models
ordered to operate on LP gas are shipped with a
NATURAL gas conversion kit.
High Altitude Conversion Kit - For operation
above 6,000 feet, order Part #WB28K10553. This
kit includes orifices for both LP and Natural gas
operation.
A manual shut-off valve in the gas line (not
provided), should be installed in an easily accessible
location. Make sure the homeowner knows where
and how to shut off the gas supply to the range.
Installation
Range Electric Supply
These ranges must be supplied with 120 volt, 60 Hz.,
and connected to a dedicated, properly grounded
branch circuit protected by a 15 amp circuit breaker
or time delay fuse.
The power cord of this appliance is equipped with
a three-prong (grounding) plug, which mates with a
standard three-prong grounding wall receptacle to
minimize the possibility of shock hazard.
If the electrical service provided does not meet
the above specifications, it is recommended that a
licensed electrician install an approved outlet.
The range must be electrically grounded in
accordance with local codes, in accordance with
National Electrical Code (ANSI/NFPA 70, latest
edition). In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian
Electrical Code Part 1. See Electrical Connections in
this section.
Backsplash Requirements
All models require 12" minimum clearance to a
vertical combustible surface at the rear. In a range
installation, if clearance is less than 12", the entire
surface of the back wall above and the full width
of the range must be protected by a backsplash.
The backsplash must be constructed of non-
combustible material, such as metal, ceramic tile,
brick, marble or other stone.
WARNING: Installations without a hood require
48" minimum to combustibles. A custom hood
installation with exposed horizontal combustible
surfaces must have an Auto-On feature. Refer to
hood installation instructions for specific hood
clearances.